Semiquantitative Visual Detection of Lead Ions with a Smartphone via a Colorimetric Paper-Based Analytical Device

Wang, Haiqian, Yang, Liang, Chu, Suyun, Liu, Bianhua, Zhang, Qikai, Zou, Lanmei, Yu, Shaoming, Jiang, Changlong·2019·Analytical Chemistry

Abstract

A simple, instrument-free, paper-based analytical device with dual-emission carbon dots (CDs) (blue CDs and red CDs) was developed for the semiquantitative, visual, and sensitive speciation analysis of lead ions in a real sample with a sensitive detection limit of 2.89 nM. When a paper strip was immersed into the sample solution, the blue fluorescence was quenched by Pb 2+ in solution, while the red fluorescence served as a background reference without color change, and significant color evolutions from blue to red were observed under the ultraviolet lamp, resulting in a semiquantitative visual detection. Furthermore, a smartphone was used in the visual detection of lead ions by identifying the RGB value of the fluorescent probe solution and corresponding paper strip. The application of smartphones and fluorescent paper strips has greatly shortened the detection time and reduced the cost of detection, providing a new strategy for the on-site and semiquantitative detection of heavy-metal ions in water samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.9b02297

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

See all 400

Metadata

Authors
Wang, H., Yang, L., Chu, S., Liu, B., Zhang, Q., Zou, L., Yu, S., & Jiang, C.
Venue
Analytical Chemistry
Published
2019-06-20
Volume
91
Issue
14
Pages
9292-9299
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2950328878
Cited by
400
References
23
FWCI
19.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Semiquantitative Visual Detection of Lead Ions with a Smartphone via a Colorimetric Paper-Based Analytical Device. https://app.cochat.ai/papers/10.1021/acs.analchem.9b02297
The paper
Wang, H., Yang, L., Chu, S., Liu, B., Zhang, Q., Zou, L., Yu, S., & Jiang, C. (2019). Semiquantitative Visual Detection of Lead Ions with a Smartphone via a Colorimetric Paper-Based Analytical Device. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.9b02297

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.