Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 310

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Universal Ti3C2 MXenes Based Self-Standard Ratiometric Fluorescence Resonance Energy Transfer Platform for Highly Sensitive Detection of Exosomes

Zhang, Qiuxia, Wang, Feng, Zhang, Huixin, Zhang, Youyu, Liu, Meiling, Liu, Yang·2018·Analytical Chemistry

Abstract

Exosomes, as novel noninvasive biomarkers for disease prediction and diagnosis, have shown fascinating prospects in monitoring cancer-linked public health issues. Herein, a unique Cy3 labeled CD63 aptamer (Cy3-CD63 aptamer)/Ti 3 C 2 MXenes nanocomplex was constructed as a self-standard ratiometric fluorescence resonance energy transfer (FRET) nanoprobe for quantitative detection of exosomes. The Cy3-CD63 aptamer can be selectively adsorbed onto the Ti 3 C 2 MXene nanosheets by hydrogen bond and metal chelate interaction between the aptamer and MXenes, and the fluorescence signal from Cy3-CD63 aptamer was quenched quickly owing to the FRET between the Cy3 and MXenes. The fluorescence of Cy3 greatly recovered after the addition of the exosomes which can specifically combine with the aptamer and release from the surface of Ti 3 C 2 MXenes due to the high affinity between the aptamer and CD63 protein on exosome surface. Meanwhile, the self-fluorescence signal of MXenes in the whole process showed little change, which can be used as a standard reference. Based on the self-standard turn-on FRET biosensing platform the detection limit of exosome was determined as 1.4 × 10 3 particles mL –1, which was over 1000× lower than that of conventional ELISA method. This fluorescence sensor can also be used for the identification of multiple biomarkers on the exosome surface and different kinds of exosomes, combining with the fluorescent confocal scanning microscope image. The proposed strategy not only provides a universal nanoplatform for exosomes, but also can be extensively expanded to multiple biomarkers detection, which may promise the prospect of MXenes as robust candidates in biological fields.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.8b03083

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 310

Metadata

Authors
Zhang, Q., Wang, F., Zhang, H., Zhang, Y., Liu, M., & Liu, Y.
Venue
Analytical Chemistry
Published
2018-10-10
Volume
90
Issue
21
Pages
12737-12744
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2897023665
Cited by
310
References
2
FWCI
9.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Universal Ti3C2 MXenes Based Self-Standard Ratiometric Fluorescence Resonance Energy Transfer Platform for Highly Sensitive Detection of Exosomes. https://app.cochat.ai/papers/10.1021/acs.analchem.8b03083
The paper
Zhang, Q., Wang, F., Zhang, H., Zhang, Y., Liu, M., & Liu, Y. (2018). Universal Ti3C2 MXenes Based Self-Standard Ratiometric Fluorescence Resonance Energy Transfer Platform for Highly Sensitive Detection of Exosomes. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.8b03083

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.