The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Wearable All-Solid-State Potentiometric Microneedle Patch for Intradermal Potassium Detection
Open accessAbstract
Abstract A new analytical all-solid-state platform for intradermal potentiometric detection of potassium in interstitial fluid is presented here. Solid microneedles are modified with different coatings and polymeric membranes to prepare both the potassium-selective electrode and reference electrode needed for the potentiometric readout. These microneedle-based electrodes are fixed in an epidermal patch suitable for insertion into the skin. The analytical performances observed for the potentiometric cell (Nernstian slope, limit of detection of 10–4.9 potassium activity, linear range of 10–4.2 to 10–1.1, drift of 0.35 ± 0.28 mV h–1), together with a fast response time, adequate selectivity, and excellent reproducibility and repeatability, are appropriate for potassium analysis in interstitial fluid within both clinical and harmful levels. The potentiometric response is maintained after several insertions into animal skin, confirming the resiliency of the microneedle-based sensor. Ex vivo tests based on the intradermal detection of potassium in chicken and porcine skin demonstrate that the microneedle patch is suitable for monitoring potassium changes inside the skin. In addition, the dimensions of the microneedles modified with the corresponding layers necessary to enhance robustness and provide sensing capabilities (1000 μm length, 45° tip angle, 15 μm thickness in the tip, and 435 μm in the base) agree with the required ranges for a painless insertion into the skin. In vitro cytotoxicity experiments showed that the patch can be used for at least 24 h without any side effect for the skin cells. Overall, the developed concept constitutes important progress in the intradermal analysis of ions related to an electrolyte imbalance in humans, which is relevant for the control of certain types of diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Eysenbach, G. (2001) · Journal of Medical Internet Research · doi:10.2196/jmir.3.2.e20 · Cited by 2,449
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
A Textile‐Based Stretchable Multi‐Ion Potentiometric Sensor
Parrilla, M., Cánovas, R., Jeerapan, I., Andrade, F. J., & Wang, J. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600092 · Cited by 269
Self-citationWearable physiological systems and technologies for metabolic monitoring
Gao, W., Brooks, G. A., & Klonoff, D. C. (2018) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00407.2017 · Cited by 91
Cited by
Tehrani, F., Teymourian, H., Wuerstle, B., Kavner, J., Patel, R., Furmidge, A., Aghavali, R., Hosseini-Toudeshki, H., Brown, C., Zhang, F., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00887-1 · Cited by 625
Recent Advances in Electrochemical Biosensors: Applications, Challenges, and Future Scope
Singh, A., Sharma, A., Ahmed, A., Sundramoorthy, A. K., Furukawa, H., Arya, S., & Khosla, A. (2021) · Biosensors · doi:10.3390/bios11090336 · Cited by 579
A critical review on the use of potentiometric based biosensors for biomarkers detection
Karimi-Maleh, H., Orooji, Y., Karimi, F., Alizadeh, M., Baghayeri, M., Rouhi, J., Tajik, S., Beitollahi, H., Agarwal, S., Gupta, V. K., et al. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113252 · Cited by 473
Shao, Y., Ying, Y., & Ping, J. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00587k · Cited by 472
Broza, Y. Y., Zhou, X., Yuan, M., Qu, D., Zheng, Y., Vishinkin, R., Khatib, M., Wu, W., & Haick, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00437 · Cited by 461
Metadata
- Authors
- Parrilla, M., Cuartero, M., Padrell Sánchez, S., Rajabi, M., Roxhed, N., Niklaus, F., & Crespo, G. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-12-13
- Volume
- 91
- Issue
- 2
- Pages
- 1578-1586
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2903635237
- Cited by
- 209
- References
- 4
- FWCI
- 7.46
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wearable All-Solid-State Potentiometric Microneedle Patch for Intradermal Potassium Detection. https://app.cochat.ai/papers/10.1021/acs.analchem.8b04877
- The paper
- Parrilla, M., Cuartero, M., Padrell Sánchez, S., Rajabi, M., Roxhed, N., Niklaus, F., & Crespo, G. A. (2019). Wearable All-Solid-State Potentiometric Microneedle Patch for Intradermal Potassium Detection. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.8b04877
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.