The DOI matches its Crossref record; 117 of the 117 references it cites were found in a registry or an index.
Recent Advances in Electrochemical Biosensors: Applications, Challenges, and Future Scope
Open accessAbstract
The electrochemical biosensors are a class of biosensors which convert biological information such as analyte concentration that is a biological recognition element (biochemical receptor) into current or voltage. Electrochemical biosensors depict propitious diagnostic technology which can detect biomarkers in body fluids such as sweat, blood, feces, or urine. Combinations of suitable immobilization techniques with effective transducers give rise to an efficient biosensor. They have been employed in the food industry, medical sciences, defense, studying plant biology, etc. While sensing complex structures and entities, a large data is obtained, and it becomes difficult to manually interpret all the data. Machine learning helps in interpreting large sensing data. In the case of biosensors, the presence of impurity affects the performance of the sensor and machine learning helps in removing signals obtained from the contaminants to obtain a high sensitivity. In this review, we discuss different types of biosensors along with their applications and the benefits of machine learning. This is followed by a discussion on the challenges, missing gaps in the knowledge, and solutions in the field of electrochemical biosensors. This review aims to serve as a valuable resource for scientists and engineers entering the interdisciplinary field of electrochemical biosensors. Furthermore, this review provides insight into the type of electrochemical biosensors, their applications, the importance of machine learning (ML) in biosensing, and challenges and future outlook.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
The Nature of Statistical Learning Theory
Vapnik, V. N. (1995) · doi:10.1007/978-1-4757-2440-0 · Cited by 39,138
A Tutorial on Support Vector Machines for Pattern Recognition
Burges, C. J. C. (1998) · Data Mining and Knowledge Discovery · doi:10.1023/a:1009715923555 · Cited by 16,429
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Deep Convolutional and LSTM Recurrent Neural Networks for Multimodal Wearable Activity Recognition
Ordóñez, F., & Roggen, D. (2016) · Sensors · doi:10.3390/s16010115 · Cited by 2,761
Support Vector Method for Function Approximation, Regression Estimation, and Signal Processing
Vapnik, V. N., Golowich, S. E., & Smola, A. J. (1997) · Cited by 2,757
Brain Tumor Segmentation Using Convolutional Neural Networks in MRI Images
Pereira, S., Pinto, A., Alves, V., & Silva, C. A. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2538465 · Cited by 2,735
Machine Learning Algorithms - A Review
Mahesh, B. (2020) · International Journal of Science and Research (IJSR) · doi:10.21275/art20203995 · Cited by 2,510
Research works printed but not linked: 58
- Khosla, A. (2011). Micropatternable Multifunctional Nanocomposite Polymers for Flexible Soft MEMS Applications. [Ph.D. Thesis, Applied Science: School of Engineering Science, Simon Fraser University].
- Ahmad, 2020, Hydrothermally synthesiz0ed nickel oxide nanosheets for non-enzymatic electrochemical glucose detection, J. Electrochem. Soc., 167, 107504, 10.1149/1945-7111/ab9757 · doi:10.1149/1945-7111/ab9757
- Chullasat, 2011, Ultra trace analysis of small molecule by label-free impedi-metric immunosensor using multilayer modified electrode, Biosens. Bioelectron., 26, 4571, 10.1016/j.bios.2011.05.029 · doi:10.1016/j.bios.2011.05.029
- Canbaz, 2014, Electrochemical biosensor based on self-assembled monolayersmodifi ed with gold nanoparticles for detection of HER-3, Anal Chim. Acta., 814, 31, 10.1016/j.aca.2014.01.041 · doi:10.1016/j.aca.2014.01.041
- Kim, 2009, An impedimetric biosensor for real-time monitoring of bacterial growth in a microbial fermentor, Sens. Actuators B Chem., 138, 270, 10.1016/j.snb.2009.01.034 · doi:10.1016/j.snb.2009.01.034
- Srisomwat, 2020, Pop-up paper electrochemical device for label-free hepatitis B virus DNA detection, Sens. Actuators B Chem., 316, 128077, 10.1016/j.snb.2020.128077 · doi:10.1016/j.snb.2020.128077
- Sannini, 2015, An amperometric biosensor for the determination of lactic acid during malolactic fermentation, Chem. Eng. Trans., 44, 283
- Ciriello, 2015, Quantification of l-lysine in cheese by a novel amperometric biosensor, Food Chem., 169, 13, 10.1016/j.foodchem.2014.07.141 · doi:10.1016/j.foodchem.2014.07.141
- Habtamu, 2015, Miniaturized Enzymatic Biosensor via Biofunctionalization of the Insulator of Nanoelectrode Ensembles, Electroanalysis, 27, 2187, 10.1002/elan.201500115 · doi:10.1002/elan.201500115
- Malvano, 2015, Ethanol content in must grape by alcohol dehydrogenase biosensors based on doped Polyaniline modified screen printed electrodes, Chem. Eng. Trans., 43, 37
- Tortolini, 2016, Inhibition-based biosensor for atrazine detection, Sens. Actuators B Chem., 224, 552, 10.1016/j.snb.2015.10.095 · doi:10.1016/j.snb.2015.10.095
- Grattieri, 2015, Enzymatic Oxygen Microsensor Based on Bilirubin Oxidase Applied to Microbial Fuel Cells Analysis, Electroanalysis, 27, 327, 10.1002/elan.201400543 · doi:10.1002/elan.201400543
- Silletti, 2015, An optical biosensor based on a multiarray of enzymes for monitoring a large set of chemical classes in milk, Sens. Actuators B Chem., 215, 607, 10.1016/j.snb.2015.03.092 · doi:10.1016/j.snb.2015.03.092
- Chiavaioli, 2015, Sol-Gel-Based Titania-Silica Thin Film Overlay for Long Period Fiber Grating-Based Biosensors, Anal. Chem., 87, 12024, 10.1021/acs.analchem.5b01841 · doi:10.1021/acs.analchem.5b01841
- Tardivo, 2015, Parallel optical read-out of micromechanical pillars applied to prostate specific membrane antigen detection, Biosens. Bioelectron., 72, 393, 10.1016/j.bios.2015.05.026 · doi:10.1016/j.bios.2015.05.026
- Scarano, 2015, Design of a dual aptamer-based recognition strategy for human matrix metalloproteinase 9 protein by piezoelectric biosensors, Anal. Chim. Acta, 897, 1, 10.1016/j.aca.2015.07.009 · doi:10.1016/j.aca.2015.07.009
- Ravalli, 2015, A label-free electrochemical affisensor for cancer marker detection: The case of HER2, Bioelectrochemistry, 106, 268, 10.1016/j.bioelechem.2015.07.010 · doi:10.1016/j.bioelechem.2015.07.010
- Benetti, 2015, A surface acoustic wave bio-electronic nose for detection of volatile odorant molecules, Biosens. Bioelectron., 67, 516, 10.1016/j.bios.2014.09.027 · doi:10.1016/j.bios.2014.09.027
- Cennamo, N., Giovanni, S.D., Varriale, A., Staiano, M., Di Pietrantonio, F., Notargiacomo, A., Zeni, L., and D’Auria, S. (2015). Easy to use plastic optical fiber-based biosensor for detection of butanal. PLoS ONE, 10. · doi:10.1371/journal.pone.0116770
- Compagnone, 2015, Quartz crystal microbalance gas sensor arrays for the quality control of chocolate, Sens. Actuators B Chem., 207, 1114, 10.1016/j.snb.2014.10.049 · doi:10.1016/j.snb.2014.10.049
- Zuccaro, 2015, Real-Time Label-Free Direct Electronic Monitoring of Topoisomerase Enzyme Binding Kinetics on Graphene, ACS Nano, 9, 11166, 10.1021/acsnano.5b05709 · doi:10.1021/acsnano.5b05709
- Lacina, 2018, Biosensing based on electrochemical impedance spectroscopy: Influence of the often-ignored molecular charge, Electrochem. Commun., 93, 183, 10.1016/j.elecom.2018.07.015 · doi:10.1016/j.elecom.2018.07.015
- Raoof, 2015, Genosensor for Point Mutation Detection of P53 Gene PCR Product Using Magnetic Particles, Electroanalysis, 27, 1378, 10.1002/elan.201400660 · doi:10.1002/elan.201400660
- Wu, 2017, Gold nanoparticles dotted reduction Graphene oxide Nanocomposite based electrochemical Aptasensor for selective, rapid, sensitive and congener-specific PCB77 detection, Sci. Rep., 7, 1
- Rodriguez, 2002, Conductometric uric acid and urea biosensor prepared from electroconductive polyaniline–poly (n-butyl methacrylate) composites, Sens. Actuators B: Chem., 85, 19, 10.1016/S0925-4005(02)00045-X · doi:10.1016/s0925-4005(02)00045-x
- Li, 2011, Fabrication and testing of thermally responsive hydrogel-based actuators using polymer heater elements for flexible microvalves, Microfluidics, BioMEMS, and Medical Microsystems IX, Volume 7929, 79290G-1
- Ahmad, 2014, High performance cholesterol sensor based on ZnO nanotubes grown on Si/Ag electrodes, Electrochem. Commun., 38, 4, 10.1016/j.elecom.2013.10.028 · doi:10.1016/j.elecom.2013.10.028
- Ahmad, 2013, High-performance cholesterol sensor based on the solution-gated field effect transistor fabricated with ZnO nanorods, Biosens. Bioelectron., 45, 281, 10.1016/j.bios.2013.01.021 · doi:10.1016/j.bios.2013.01.021
- Wang, 2012, Highly-sensitive cholesterol biosensor based on platinum-gold hybrid functionalized ZnO nanorods, Talanta, 94, 263, 10.1016/j.talanta.2012.03.037 · doi:10.1016/j.talanta.2012.03.037
- Batra, 2015, ZnO-CuO composite matrix based reagentless biosensor for detection of total cholesterol, Biosens. Bioelectron., 67, 263, 10.1016/j.bios.2014.08.029 · doi:10.1016/j.bios.2014.08.029
- Oh, 2016, An ultrasensitive and incubation-free electrochemicalimmunosensor using a gold-nanocatalyst label mediating outer-spherereaction-philic and inner-sphere-reaction-philic species, Chem. Commun., 52, 5884, 10.1039/C6CC00353B · doi:10.1039/c6cc00353b
- Cai, 2016, Ratiometric electrochemical immunoassay based on internalreference value for reproducible and sensitive detection of tumor marker, Biosens. Bioelectron., 81, 173, 10.1016/j.bios.2016.02.066 · doi:10.1016/j.bios.2016.02.066
- Zhang, 2016, A novel electrochemical immunosensor based onnonenzymatic Ag@au-Fe3O4 nanoelectrocatalyst for protein biomarkerdetection, Biosens. Bioelectron., 85, 343, 10.1016/j.bios.2016.04.100 · doi:10.1016/j.bios.2016.04.100
- Xu, 2007, Biosensor based on self-assembling glucose oxidase and Dendrimer-encapsulated Pt nanoparticles on carbon nanotubes for glucosedetection, Electroanalysis, 19, 717, 10.1002/elan.200603805 · doi:10.1002/elan.200603805
- Gupta, 2017, Ultrasensitive transglutaminase based nanosensor for early detection of celiac dis- ease in human, Int. J. Biol. Macromol., 105, 905, 10.1016/j.ijbiomac.2017.07.126 · doi:10.1016/j.ijbiomac.2017.07.126
- Neves, 2012, Celiac disease detection using a transglutaminase electro-chemical immunosensor fabricated on nanohybrid screen-printed carbon electrodes, Biosens. Bioelectron., 31, 95, 10.1016/j.bios.2011.09.044 · doi:10.1016/j.bios.2011.09.044
- Hianik, 2005, Detection of aptamer—protein interactions using QCM and electrochemical indicator methods, Bioorg. Med. Chem., 15, 291, 10.1016/j.bmcl.2004.10.083 · doi:10.1016/j.bmcl.2004.10.083
- Arya, 2019, Comparative study of CuO, CuO@ Ag and CuO@ Ag: La nanoparticles for their photosensing properties, Mater. Res. Express, 6, 116313, 10.1088/2053-1591/ab49ab · doi:10.1088/2053-1591/ab49ab
- Marks, R.S., and Abdulhalim, I. (2015). Nanomaterials for Water Management: Signal Amplification for Biosensing from Nanostructures, CRC Press. · doi:10.1201/b18715
- Ly, 2011, Diagnosis of Helicobacter pylori bacterial infections using a voltammetric biosensor, J. Microbiol. Methods, 87, 44, 10.1016/j.mimet.2011.07.002 · doi:10.1016/j.mimet.2011.07.002
- Wang, J. (2006). Analytical Electrochemistry Hoboken, John Wiley & Sons, Inc.
- Elshafey, 2013, Electrochemical impedance immunosensor based on gold nanoparticles—protein G for the detection of cancer marker epidermal growth factor receptor in human plasma and brain tissue, Biosens. Bioelectron., 50, 143, 10.1016/j.bios.2013.05.063 · doi:10.1016/j.bios.2013.05.063
- Seven, 2013, Impedimetric biosensor for cancer cell detection, Electrochem. Commun., 37, 36, 10.1016/j.elecom.2013.10.003 · doi:10.1016/j.elecom.2013.10.003
- Chowdhury, 2012, Label free polyaniline based impedimetric biosensor for detection of E. coli O157: H7 Bacteria, Sens. Actuators B Chem., 171, 916, 10.1016/j.snb.2012.06.004 · doi:10.1016/j.snb.2012.06.004
- Shirsat, 2007, Amperometric glucose biosensor on layer bylayer assembled carbon nanotube and Polypyrrole multilayer film, Electroanalysis, 20, 150, 10.1002/elan.200704028 · doi:10.1002/elan.200704028
- Jakhar, 2018, Preparation, characterization and application of urease nanoparticles for construction of an improved potentiometric urea biosensor, Biosens. Bioelectron., 100, 242, 10.1016/j.bios.2017.09.005 · doi:10.1016/j.bios.2017.09.005
- Singh, 2021, Promising photocatalytic degradation of methyl orange dye via sol-gel synthesized Ag–CdS@ Pr-TiO2 core/shell nanoparticles, Phys. B Condens. Matter, 616, 413121, 10.1016/j.physb.2021.413121 · doi:10.1016/j.physb.2021.413121
- Chung, 2013, Investigations of flexible Ag/AgCl nanocomposite polymer electrodes for suitability in tissue electrical impedance scanning (EIS), J. Electrochem. Soc., 161, B3071, 10.1149/2.018402jes · doi:10.1149/2.018402jes
- Singh, A., Arya, S., Khanuja, M., Hafiz, A.K., Datt, R., Gupta, V., and Khosla, A. (2020). Eu doped NaYF 4@ Er: TiO 2 nanoparticles for tunable ultraviolet light based anti-counterfeiting applications. Microsyst. Technol., 1–10. · doi:10.1007/s00542-019-04734-3
- Choi, 1998, Evaluation of two types of biosensors for immunoassay of botulinum toxin, J. Biochem. Mol. Biol., 31, 101
- Gaffar, 2017, Voltammetric DNA biosensor using gold electrode modified by self assembled monolayer of Thiol for detection of mycobacterium tuberculosis, Procedia Technol., 27, 74, 10.1016/j.protcy.2017.04.034 · doi:10.1016/j.protcy.2017.04.034
- Jamal, 2018, A non enzymatic glutamate sensor based on nickel oxide nanoparticle, Microsyst. Technol., 24, 4217, 10.1007/s00542-018-3724-6 · doi:10.1007/s00542-018-3724-6
- Wang, 2017, Detection of extremely low concentration waterborne pathogen using a multiplexing selfreferencing SERS microfluidic biosensor, J. Biol. Eng., 11, 9, 10.1186/s13036-017-0051-x · doi:10.1186/s13036-017-0051-x
- Olano, 2015, The influence of sky conditions on the standardized calibration of pyranometers and on the measurement of global solar irradiation, Sol. Energy, 121, 116, 10.1016/j.solener.2015.07.031 · doi:10.1016/j.solener.2015.07.031
- Massah, 2013, An artificial neural network approach to identify fungal diseases of cucumber (Cucumis sativus L.) plants using digital image processing, Arch. Phytopathol. Plant Protect., 46, 1580, 10.1080/03235408.2013.772321 · doi:10.1080/03235408.2013.772321
- Bailer, C., Habtegebrial, T., Varanasi, K., and Stricker, D. (2018). Fast Feature Extraction with CNNs with Pooling Layers. arXiv.
- Lipton, Z.C., Berkowitz, J., and Elkan, C. (2015). A critical review of recurrent neural networks for sequence learning. arXiv.
- Williams, J.D., and Zweig, G. (2016). End-to-end lstm-based dialog control optimized with supervised and reinforcement learning. arXiv.
Metadata
- Authors
- Singh, A., Sharma, A., Ahmed, A., Sundramoorthy, A. K., Furukawa, H., Arya, S., & Khosla, A.
- Venue
- Biosensors
- Publisher
- MDPI AG
- Published
- 2021-09-14
- Volume
- 11
- Issue
- 9
- Pages
- 336
- ISSN
- 2079-6374 (ISSN-L)
- OpenAlex
- W3200063015
- Cited by
- 579
- References
- 117
- FWCI
- 23.26
- Type
- journal article
- Language
- en
- Open access
- gold
- Funders
- Japan Society for the Promotion of Science (JP17H01224, JP18H0547, JP19H01122)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recent Advances in Electrochemical Biosensors: Applications, Challenges, and Future Scope. https://app.cochat.ai/papers/10.3390/bios11090336
- The paper
- Singh, A., Sharma, A., Ahmed, A., Sundramoorthy, A. K., Furukawa, H., Arya, S., & Khosla, A. (2021). Recent Advances in Electrochemical Biosensors: Applications, Challenges, and Future Scope. Biosensors. https://doi.org/10.3390/bios11090336
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.