Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 194

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Fluorescent Graphitic Carbon Nitride-Based Nanozymes with Peroxidase-Like Activities for Ratiometric Biosensing

Wang, Xiaoyu, Qin, Li, Lin, Minjie, Xing, Hang, Wei, Hui·2019·Analytical Chemistry

Abstract

While breakthroughs in peroxidase-like nanozymes for bioanalysis have been made, most of current nanozyme biosensing systems are based on a single signal output. Such sensing systems could be easily influenced by environmental and personal factors. We envision that nanozyme sensing systems with ratiometric signal outputs would provide more reliable and robust sensing performance. Herein, to construct such ratiometric sensing systems, three fluorescent graphitic carbon nitride (C 3 N 4 )-based nanozymes (i.e., C 3 N 4 –Ru, C 3 N 4 –Cu, and C 3 N 4 –hemin) with excellent peroxidase-like activities were prepared. These fluorescent nanozymes emitted a fluorescence at 438 nm when excited at 385 nm. Interestingly, when o -phenylenediamine (OPD) was catalytically oxidized to oxidized OPD (OPDox) in the presence of H 2 O 2 and nanozymes, the OPDox not only emitted an emerging fluorescence at 564 nm but also quenched the fluorescence at 438 nm of the nanozymes. We therefore employed the ratio of the fluorescent intensity at 564 and 438 nm (i.e., F 564 / F 438 ) as the signal output to construct the ratiometric biosensing systems. First, we used the C 3 N 4 –Ru nanozyme to construct the ratiometric H 2 O 2 sensing system, which showed not only the enhanced robustness but also wider linear range and better sensitivity than most reported H 2 O 2 sensors based on nanozymes. Second, with the assistance of glucose oxidase, glucose can be detected by such ratiometric sensing systems. Third, we used three different C 3 N 4 -based nanozymes to construct ratiometric sensor arrays for the detection and discrimination of five phosphates. This study provides new insights for constructing robust nanozyme biosensing systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.9b01884

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 194

Metadata

Authors
Wang, X., Qin, L., Lin, M., Xing, H., & Wei, H.
Venue
Analytical Chemistry
Published
2019-07-18
Volume
91
Issue
16
Pages
10648-10656
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2964034253
Cited by
194
References
2
FWCI
8.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fluorescent Graphitic Carbon Nitride-Based Nanozymes with Peroxidase-Like Activities for Ratiometric Biosensing. https://app.cochat.ai/papers/10.1021/acs.analchem.9b01884
The paper
Wang, X., Qin, L., Lin, M., Xing, H., & Wei, H. (2019). Fluorescent Graphitic Carbon Nitride-Based Nanozymes with Peroxidase-Like Activities for Ratiometric Biosensing. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.9b01884

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.