Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 244

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

MXene Titanium Carbide-based Biosensor: Strong Dependence of Exfoliation Method on Performance

Chia, Hui Ling, Mayorga-Martinez, Carmen C., Antonatos, Nikolas, Sofer, Zdeněk, Gonzalez-Julian, Jesus J., Webster, Richard D., Pumera, Martin·2020·Analytical Chemistry

Abstract

Transition metal carbides, known as MXenes, are generated via the selective etching of “A” layers from their layered, ternary parent compounds, MAX phases, where M corresponds to early d -transition metal, A being a main group sp -element from either Group 13 or 14 and carbon or nitrogen being denoted by X. MXenes are being recognized as a new and uprising class of 2D materials with extraordinary physical and electrochemical properties. The huge specific surface area and outstanding electrical conductivity of MXenes, make them ideal candidates for sensing and energy applications. Herein, we demonstrated the successful incorporation of pristine MXene, Ti 3 C 2 produced via HF etching and subsequent delamination with TBAOH, as a transducer platform toward the development of a second generation electrochemical glucose biosensor. Chronoamperometric studies demonstrate that the proposed biosensing system exhibits high selectivity and excellent electrocatalytic activity toward the detection of glucose, spanning over wide linear ranges of 50–27 750 μM and possess a low limit of detection of 23.0 μM. The findings reported in this study conceptually proves the probable applications of pristine MXenes toward the field of biosensors and pave ways for the future developments of highly selective and sensitive electrochemical biosensors for biomedical and food sampling applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.9b03634

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 244

Metadata

Authors
Chia, H. L., Mayorga-Martinez, C. C., Antonatos, N., Sofer, Z., Gonzalez-Julian, J. J., Webster, R. D., & Pumera, M.
Venue
Analytical Chemistry
Published
2020-01-24
Volume
92
Issue
3
Pages
2452-2459
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W3001125547
Cited by
244
References
3
FWCI
12.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MXene Titanium Carbide-based Biosensor: Strong Dependence of Exfoliation Method on Performance. https://app.cochat.ai/papers/10.1021/acs.analchem.9b03634
The paper
Chia, H. L., Mayorga-Martinez, C. C., Antonatos, N., Sofer, Z., Gonzalez-Julian, J. J., Webster, R. D., & Pumera, M. (2020). MXene Titanium Carbide-based Biosensor: Strong Dependence of Exfoliation Method on Performance. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.9b03634

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.