The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
MXene Titanium Carbide-based Biosensor: Strong Dependence of Exfoliation Method on Performance
Abstract
Transition metal carbides, known as MXenes, are generated via the selective etching of “A” layers from their layered, ternary parent compounds, MAX phases, where M corresponds to early d -transition metal, A being a main group sp -element from either Group 13 or 14 and carbon or nitrogen being denoted by X. MXenes are being recognized as a new and uprising class of 2D materials with extraordinary physical and electrochemical properties. The huge specific surface area and outstanding electrical conductivity of MXenes, make them ideal candidates for sensing and energy applications. Herein, we demonstrated the successful incorporation of pristine MXene, Ti 3 C 2 produced via HF etching and subsequent delamination with TBAOH, as a transducer platform toward the development of a second generation electrochemical glucose biosensor. Chronoamperometric studies demonstrate that the proposed biosensing system exhibits high selectivity and excellent electrocatalytic activity toward the detection of glucose, spanning over wide linear ranges of 50–27 750 μM and possess a low limit of detection of 23.0 μM. The findings reported in this study conceptually proves the probable applications of pristine MXenes toward the field of biosensors and pave ways for the future developments of highly selective and sensitive electrochemical biosensors for biomedical and food sampling applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Emerging Risk Factors Collaboration (2010) · The Lancet · doi:10.1016/s0140-6736(10)60484-9 · Cited by 5,125
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137
Cited by
Ti3C2TX MXene for Sensing Applications: Recent Progress, Design Principles, and Future Perspectives
Pei, Y., Zhang, X., Hui, Z., Zhou, J., Huang, X., Sun, G., & Huang, W. (2021) · ACS Nano · doi:10.1021/acsnano.1c00248 · Cited by 799
Manickam, P., Mariappan, S. A., Murugesan, S. M., Hansda, S., Kaushik, A., Shinde, R., & Thipperudraswamy, S. P. (2022) · Biosensors · doi:10.3390/bios12080562 · Cited by 637
Two-dimensional materials in biomedical, biosensing and sensing applications
Rohaizad, N., Mayorga-Martinez, C. C., Fojtů, M., Latiff, N. M., & Pumera, M. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00150c · Cited by 506
Self-citationSensing with MXenes: Progress and Prospects
Ho, D. H., Choi, Y. Y., Jo, S. B., Myoung, J., & Cho, J. H. (2021) · Advanced Materials · doi:10.1002/adma.202005846 · Cited by 482
Surface functionalization of MXenes
Mozafari, M., & Soroush, M. (2021) · Materials Advances · doi:10.1039/d1ma00625h · Cited by 395
Metadata
- Authors
- Chia, H. L., Mayorga-Martinez, C. C., Antonatos, N., Sofer, Z., Gonzalez-Julian, J. J., Webster, R. D., & Pumera, M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-01-24
- Volume
- 92
- Issue
- 3
- Pages
- 2452-2459
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W3001125547
- Cited by
- 244
- References
- 3
- FWCI
- 12.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MXene Titanium Carbide-based Biosensor: Strong Dependence of Exfoliation Method on Performance. https://app.cochat.ai/papers/10.1021/acs.analchem.9b03634
- The paper
- Chia, H. L., Mayorga-Martinez, C. C., Antonatos, N., Sofer, Z., Gonzalez-Julian, J. J., Webster, R. D., & Pumera, M. (2020). MXene Titanium Carbide-based Biosensor: Strong Dependence of Exfoliation Method on Performance. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.9b03634
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.