CoChat

Simultaneous High-Purity Enantiomeric Resolution of Conglomerates Using Magnetic Substrates

Open access

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

High Resolution Image Download MS PowerPoint Slide Applying magnetic substrates, magnetized perpendicular to the surface, we were able to crystallize from racemic solution pure conglomerates of several molecules. The resolution is based on the spin-dependent charge reorganization (SDCR) effect. By having two surfaces with opposite magnetization, it was possible to simultaneously crystallize on each surface a different enantiomer. The method does not require any seeding or chemical modification and is generally employable to any conglomerate. A system is presented for performing the separation, while the racemic mixture flows between the two magnetic surfaces.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.cgd.1c00093

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Research works printed but not linked: 3

  1. Food and Drug Administration, 1992, Fed. Regist., 57, FR22249
  2. Committee for Proprietary Medical Products, 1993, Working Parties on Quality, Safety and Efficacy of Medicinal Products. Note for Guidance: Investigation of Chiral Active Substances (III/3501/91)
  3. Jacques J., 1994, Enantiomers, Racemates and Resolution

Cited by

See all 24

Metadata

Authors
Bhowmick, D., Sang, Y., Santra, K., Halbauer, M., Capua, E., Paltiel, Y., Naaman, R., & Tassinari, F.
Affiliations
  • Department of Chemical and Biological Physics, Weizmann Institute, Rehovot 76100, Israel
  • Weizmann Institute of Science (IL)
  • Kiralis Ltd., 3 Golda Meir St., Nes-Ziona 7403648, Israel
  • Hebrew University of Jerusalem (IL)
Corresponding author
Tassinari, Francesco
Venue
Crystal Growth & Design
Published
2021-04-21
Volume
21
Issue
5
Pages
2925-2931
ISSN
  • 1528-7483 (ISSN-L)
  • 1528-7505
OpenAlex
W3158616099
Cited by
24
References
22
Citations by year
2026: 4 · 2025: 4 · 2024: 3 · 2023: 7 · 2022: 3 · 2021: 3
FWCI
1.22
Type
journal article
Language
en
Open access
Locations
  • Crystal Growth & Design (publishedVersion, cc-by)
  • IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
Funders
United States-Israel Binational Science Foundation (2018621)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Crystallization and Solubility Studies
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
  • Physical Sciences › Chemistry › Spectroscopy › Molecular spectroscopy and chirality
Keywords
enantiomer resolution, conglomerate, magnetic substrates, simultaneous crystallization, flux surfaces, enantiomer separation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simultaneous High-Purity Enantiomeric Resolution of Conglomerates Using Magnetic Substrates. https://app.cochat.ai/papers/10.1021/acs.cgd.1c00093
The paper
Bhowmick, D., Sang, Y., Santra, K., Halbauer, M., Capua, E., Paltiel, Y., Naaman, R., & Tassinari, F. (2021). Simultaneous High-Purity Enantiomeric Resolution of Conglomerates Using Magnetic Substrates. Crystal Growth & Design. https://doi.org/10.1021/acs.cgd.1c00093

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.