The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
3D Luminescent Amide-Functionalized Cadmium Tetrazolate Framework for Selective Detection of 2,4,6-Trinitrophenol
Abstract
A new 3D fluorescent amide-functionalized Cd(II)-based metal–organic framework (MOF) with molecular formula [Cd 5 Cl 6 ( L )(H L ) 2 ]·7H 2 O ( 1 ) was synthesized under solvothermal conditions using CdCl 2 ·H 2 O and 4-(1 H -tetrazol-5-yl)- N -[4-(1 H -tetrazol-5-yl)phenyl]benzamide (H 2 L ) in DMF/methanol in the presence of conc. HCl. Single-crystal X-diffraction analysis reveals that the 3D framework structure of 1 is constructed from octahedrally coordinated Cd 2+ ions interconncted by chloride anions and ditopic tetrazolate-based ligand molecules. The phase-purity of the compound was confirmed by X-ray powder diffraction (XRPD) analysis, infrared spectroscopy, and elemental analysis. Thermogravimetric analysis suggests that 1 is thermally stable up to 300 °C. Steady-state fluorescence titration experiments reveal that activated 1 ′ can selectively detect 2,4,6-trinitrophenol (TNP) in the presence of other competing nitroaromatic compounds with a detection limit of 42.84 ppb. Recyclability experiments reveal that 1 ′ retains its initial fluorescence intensity even after several cycles, suggesting high photostability and reusability for long-term sensing applications. The extraordinarily selective fluorescence quenching is assigned to the presence of energy and electron transfer processes as well as the electrostatic interactions of the MOF with TNP. This new 3D amide-functionalized MOF is a potential candidate that can be developed into a highly selective and sensitive sensing device for the in-field detection of TNP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metal-organic framework materials as catalysts
Lee, J., Farha, O. K., Roberts, J., Scheidt, K. A., Nguyen, S. T., & Hupp, J. T. (2009) · Chemical Society Reviews · doi:10.1039/b807080f · Cited by 7,969
Cited by
Metal–organic frameworks: functional luminescent and photonic materials for sensing applications
Lustig, W. P., Mukherjee, S., Rudd, N. D., Desai, A. V., Li, J., & Ghosh, S. K. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00930a · Cited by 3,050
Luminescent sensors based on metal-organic frameworks
Zhang, Y., Yuan, S., Day, G., Wang, X., Yang, X., & Zhou, H.-C. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.06.007 · Cited by 1,255
Liu, J.-Q., Luo, Z.-D., Pan, Y., Kumar Singh, A., Trivedi, M., & Kumar, A. (2020) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2019.213145 · Cited by 508
Linker functionalized metal-organic frameworks
Ali Akbar Razavi, S., & Morsali, A. (2019) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2019.213023 · Cited by 341
Han, Y., Chen, Y., Feng, J., Liu, J., Ma, S., & Chen, X. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04509 · Cited by 295
Metadata
- Authors
- Buragohain, A., Yousufuddin, M., Sarma, M., & Biswas, S.
- Venue
- Crystal Growth & Design
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-01-25
- Volume
- 16
- Issue
- 2
- Pages
- 842-851
- ISSN
- 1528-7483 (ISSN-L)
- 1528-7505
- OpenAlex
- W2233387969
- Cited by
- 193
- References
- 1
- FWCI
- 11.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3D Luminescent Amide-Functionalized Cadmium Tetrazolate Framework for Selective Detection of 2,4,6-Trinitrophenol. https://app.cochat.ai/papers/10.1021/acs.cgd.5b01427
- The paper
- Buragohain, A., Yousufuddin, M., Sarma, M., & Biswas, S. (2016). 3D Luminescent Amide-Functionalized Cadmium Tetrazolate Framework for Selective Detection of 2,4,6-Trinitrophenol. Crystal Growth & Design. https://doi.org/10.1021/acs.cgd.5b01427
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.