The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Measuring Personal Exposure to Organophosphate Flame Retardants Using Silicone Wristbands and Hand Wipes
Open accessAbstract
Organophosphate flame retardants (PFRs) are widely used as replacements for polybrominated diphenyl ethers in consumer products. With high detection in indoor environments and increasing toxicological evidence suggesting a potential for adverse health effects, there is a growing need for reliable exposure metrics to examine individual exposures to PFRs. Silicone wristbands have been used as passive air samplers for quantifying exposure in the general population and occupational exposure to polycyclic aromatic hydrocarbons. Here we investigated the utility of silicone wristbands in measuring exposure and internal dose of PFRs through measurement of urinary metabolite concentrations. Wristbands were also compared to hand wipes as metrics of exposure. Participants wore wristbands for 5 consecutive days and collected first morning void urine samples on 3 alternating days. Urine samples were pooled across 3 days and analyzed for metabolites of the following PFRs: tris(1,3-dichloroisopropyl) phosphate (TDCIPP), tris(1-chloro-2-isopropyl) phosphate (TCIPP), triphenyl phosphate (TPHP), and monosubstituted isopropylated triaryl phosphate (mono-ITP). All four PFRs and their urinary metabolites were ubiquitously detected. Correlations between TDCIPP and TCIPP and their corresponding urinary metabolites were highly significant on the wristbands (rs = 0.5-0.65, p < 0.001), which suggest that wristbands can serve as strong predictors of cumulative, 5-day exposure and may be an improved metric compared to hand wipes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SVOC exposure indoors: fresh look at dermal pathways: SVOC exposure via dermal pathways
Weschler, C. J., & Nazaroff, W. W. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00772.x · Cited by 422
Cited by
Blum, A., Behl, M., Birnbaum, L. S., Diamond, M. L., Phillips, A., Singla, V., Sipes, N. S., Stapleton, H. M., & Venier, M. (2019) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.9b00582 · Cited by 651
Self-citationRock, K. D., St Armour, G., Horman, B., Phillips, A., Ruis, M., Stewart, A. K., Jima, D., Muddiman, D. C., Stapleton, H. M., & Patisaul, H. B. (2020) · Toxicological Sciences · doi:10.1093/toxsci/kfaa046 · Cited by 69
Self-citationPersonal exposure to polycyclic aromatic hydrocarbons in Appalachian mining communities
Hendryx, M., Wang, S., Romanak, K. A., Salamova, A., & Venier, M. (2020) · Environmental Pollution · doi:10.1016/j.envpol.2019.113501 · Cited by 43
Metadata
- Authors
- Hammel, S. C., Hoffman, K., Webster, T. F., Anderson, K. A., & Stapleton, H. M.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-03-31
- Volume
- 50
- Issue
- 8
- Pages
- 4483-4491
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2299077788
- Cited by
- 217
- References
- 1
- FWCI
- 15.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measuring Personal Exposure to Organophosphate Flame Retardants Using Silicone Wristbands and Hand Wipes. https://app.cochat.ai/papers/10.1021/acs.est.6b00030
- The paper
- Hammel, S. C., Hoffman, K., Webster, T. F., Anderson, K. A., & Stapleton, H. M. (2016). Measuring Personal Exposure to Organophosphate Flame Retardants Using Silicone Wristbands and Hand Wipes. Environmental Science & Technology. https://doi.org/10.1021/acs.est.6b00030
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.