The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Highly Sensitive and Selective Uranium Detection in Natural Water Systems Using a Luminescent Mesoporous Metal–Organic Framework Equipped with Abundant Lewis Basic Sites: A Combined Batch, X-ray Absorption Spectroscopy, and First Principles Simulation Investigation
Abstract
Uranium is not only a strategic resource for the nuclear industry but also a global contaminant with high toxicity. Although several strategies have been established for detecting uranyl ions in water, searching for new uranium sensor material with great sensitivity, selectivity, and stability remains a challenge. We introduce here a hydrolytically stable mesoporous terbium(III)-based MOF material compound 1, whose channels are as large as 27 Å × 23 Å and are equipped with abundant exposed Lewis basic sites, the luminescence intensity of which can be efficiently and selectively quenched by uranyl ions. The detection limit in deionized water reaches 0.9 μg/L, far below the maximum contamination standard of 30 μg/L in drinking water defined by the United States Environmental Protection Agency, making compound 1 currently the only MOF material that can achieve this goal. More importantly, this material exhibits great capability in detecting uranyl ions in natural water systems such as lake water and seawater with pH being adjusted to 4, where huge excesses of competing ions are present. The uranyl detection limits in Dushu Lake water and in seawater were calculated to be 14.0 and 3.5 μg/L, respectively. This great detection capability originates from the selective binding of uranyl ions onto the Lewis basic sites of the MOF material, as demonstrated by synchrotron radiation extended X-ray adsorption fine structure, X-ray adsorption near edge structure, and first principles calculations, further leading to an effective energy transfer between the uranyl ions and the MOF skeleton.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Density-functional thermochemistry. III. The role of exact exchange
Becke, A. D. (1993) · The Journal of Chemical Physics · doi:10.1063/1.464913 · Cited by 103,767
Lee, C., Yang, W., & Parr, R. G. (1988) · Physical Review B · doi:10.1103/physrevb.37.785 · Cited by 100,874
Grimme, S., Antony, J., Ehrlich, S., & Krieg, H. (2010) · The Journal of Chemical Physics · doi:10.1063/1.3382344 · Cited by 59,686
Zhao, Y., & Truhlar, D. G. (2008) · Theoretical Chemistry Accounts · doi:10.1007/s00214-007-0310-x · Cited by 30,302
Marenich, A. V., Cramer, C. J., & Truhlar, D. G. (2009) · The Journal of Physical Chemistry B · doi:10.1021/jp810292n · Cited by 17,843
ATHENA,ARTEMIS,HEPHAESTUS: data analysis for X-ray absorption spectroscopy using IFEFFIT
Ravel, B., & Newville, M. (2005) · Journal of Synchrotron Radiation · doi:10.1107/s0909049505012719 · Cited by 16,965
Hehre, W. J., Ditchfield, R., & Pople, J. A. (1972) · The Journal of Chemical Physics · doi:10.1063/1.1677527 · Cited by 15,855
Contracted Gaussian basis sets for molecular calculations. I. Second row atoms, Z=11–18
McLean, A. D., & Chandler, G. S. (1980) · The Journal of Chemical Physics · doi:10.1063/1.438980 · Cited by 9,798
Clark, T., Chandrasekhar, J., Spitznagel, G. W., & Schleyer, P. V. R. (1983) · Journal of Computational Chemistry · doi:10.1002/jcc.540040303 · Cited by 7,224
Metal–Organic Framework Materials as Chemical Sensors
Kreno, L. E., Leong, K., Farha, O. K., Allendorf, M., Van Duyne, R. P., & Hupp, J. T. (2012) · Chemical Reviews · doi:10.1021/cr200324t · Cited by 7,136
Cited by
Metal–Organic Frameworks for Food Safety
Wang, P.-L., Xie, L.-H., Joseph, E. A., Li, J.-R., Su, X.-O., & Zhou, H.-C. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00257 · Cited by 533
Synthesis of novel nanomaterials and their application in efficient removal of radionuclides
Wang, X., Chen, L., Wang, L., Fan, Q., Pan, D., Li, J., Chi, F., Xie, Y., Yu, S., Xiao, C., et al. (2019) · Science China Chemistry · doi:10.1007/s11426-019-9492-4 · Cited by 365
Self-citationChen, W.-M., Meng, X.-L., Zhuang, G.-L., Wang, Z., Kurmoo, M., Zhao, Q.-Q., Wang, X.-P., Shan, B., Tung, C.-H., & Sun, D. (2017) · Journal of Materials Chemistry A · doi:10.1039/c7ta01546a · Cited by 336
Adsorption of diclofenac from aqueous solution using UiO-66-type metal-organic frameworks
Zhuang, S., Cheng, R., & Wang, J. (2019) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.11.150 · Cited by 325
Self-citation
Metadata
- Authors
- Liu, W., Dai, X., Bai, Z., Wang, Y., Yang, Z., Zhang, L., Xu, L., Chen, L., Li, Y., Gui, D., Diwu, J., Wang, J., Zhou, R., Chai, Z., & Wang, S.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-03-17
- Volume
- 51
- Issue
- 7
- Pages
- 3911-3921
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2593524057
- Cited by
- 420
- References
- 42
- FWCI
- 19.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Sensitive and Selective Uranium Detection in Natural Water Systems Using a Luminescent Mesoporous Metal–Organic Framework Equipped with Abundant Lewis Basic Sites: A Combined Batch, X-ray Absorption Spectroscopy, and First Principles Simulation Investigation. https://app.cochat.ai/papers/10.1021/acs.est.6b06305
- The paper
- Liu, W., Dai, X., Bai, Z., Wang, Y., Yang, Z., Zhang, L., Xu, L., Chen, L., Li, Y., Gui, D., Diwu, J., Wang, J., Zhou, R., Chai, Z., & Wang, S. (2017). Highly Sensitive and Selective Uranium Detection in Natural Water Systems Using a Luminescent Mesoporous Metal–Organic Framework Equipped with Abundant Lewis Basic Sites: A Combined Batch, X-ray Absorption Spectroscopy, and First Principles Simulation Investigation. Environmental Science & Technology. https://doi.org/10.1021/acs.est.6b06305
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.