Solvent-Free CO2 Capture Using Membrane Capacitive Deionization
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Capture of CO 2, originating from both fossil fuels, such as coal combustion, and from renewables, such as biogas, appears to be one of the greatest technological challenges of this century. In this study, we show that membrane capacitive deionization (MCDI) can be used to capture CO 2 as bicarbonate and carbonate ions produced from the reaction of CO 2 with water. This novel approach allows capturing CO 2 at room temperature and atmospheric pressure without the use of chemicals. In this process, the adsorption and desorption of bicarbonate ions from the deionized water solution drive the CO 2 (g) absorption–desorption from the gas phase. In this work, the effects of the current density and the CO 2 partial pressure were studied. We found that between 55 and 75% of the electrical charge of the capacitive electrodes can be directly used to absorb CO 2 gas. The energy requirement of such a system was found to be ≈40 kJ mol –1 at 15% CO 2 and could be further improved by reducing the ohmic and non-ohmic energy losses of the MCDI cell.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reducing the Cost of CO 2 Capture from Flue Gases Using Pressure Swing Adsorption
Ho, M. T., Allinson, G. W., & Wiley, D. E. (2008) · Industrial & Engineering Chemistry Research · doi:10.1021/ie070831e · Cited by 566
One-step electrosynthesis of ethylene and ethanol from CO2 in an alkaline electrolyzer
Ma, S., Sadakiyo, M., Luo, R., Heima, M., Yamauchi, M., & Kenis, P. J. A. (2016) · Journal of Power Sources · doi:10.1016/j.jpowsour.2015.09.124 · Cited by 488
Kas, R., Kortlever, R., Yılmaz, H., Koper, M. T. M., & Mul, G. (2015) · ChemElectroChem · doi:10.1002/celc.201402373 · Cited by 464
Nitrogen-Based Catalysts for the Electrochemical Reduction of CO 2 to CO
Tornow, C. E., Thorson, M. R., Ma, S., Gewirth, A. A., & Kenis, P. J. A. (2012) · Journal of the American Chemical Society · doi:10.1021/ja308217w · Cited by 190
Cited by
Direct air capture: process technology, techno-economic and socio-political challenges
Erans, M., Sanz-Pérez, E. S., Hanak, D. P., Clulow, Z., Reiner, D. M., & Mutch, G. A. (2022) · Energy & Environmental Science · doi:10.1039/d1ee03523a · Cited by 688
Sorbents for the Direct Capture of CO 2 from Ambient Air
Shi, X., Xiao, H., Azarabadi, H., Song, J., Wu, X., Chen, X., & Lackner, K. S. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201906756 · Cited by 679
Electrochemical carbon dioxide capture to close the carbon cycle
Sharifian, R., Wagterveld, R. M., Digdaya, I. A., Xiang, C., & Vermaas, D. A. (2021) · Energy & Environmental Science · doi:10.1039/d0ee03382k · Cited by 514
Various cell architectures of capacitive deionization: Recent advances and future trends
Tang, W., Liang, J., He, D., Gong, J., Tang, L., Liu, Z., Wang, D., & Zeng, G. (2019) · Water Research · doi:10.1016/j.watres.2018.11.064 · Cited by 461
Zhang, C., Ma, J., Wu, L., Sun, J., Wang, L., Li, T., & Waite, T. D. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.0c06552 · Cited by 323
Metadata
- Authors
- Legrand, L., Schaetzle, O., de Kler, R. C. F., & Hamelers, H. V. M.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-07-11
- Volume
- 52
- Issue
- 16
- Pages
- 9478-9485
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2863484248
- Cited by
- 106
- References
- 4
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Solvent-Free CO2 Capture Using Membrane Capacitive Deionization. https://app.cochat.ai/papers/10.1021/acs.est.8b00980
- The paper
- Legrand, L., Schaetzle, O., de Kler, R. C. F., & Hamelers, H. V. M. (2018). Solvent-Free CO2 Capture Using Membrane Capacitive Deionization. Environmental Science & Technology. https://doi.org/10.1021/acs.est.8b00980
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.