The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Role of Ferrate(IV) and Ferrate(V) in Activating Ferrate(VI) by Calcium Sulfite for Enhanced Oxidation of Organic Contaminants
Abstract
Although the Fe(VI)–sulfite process has shown great potential for the rapid removal of organic contaminants, the major active oxidants (Fe(IV)/Fe(V) versus SO 4 •– / • OH) involved in this process are still under debate. By employing sparingly soluble CaSO 3 as a slow-releasing source of SO 3 2–, this study evaluated the oxidation performance of the Fe(VI)–CaSO 3 process and identified the active oxidants involved in this process. The process exhibited efficient oxidation of a variety of compounds, including antibiotics, pharmaceuticals, and pesticides, at rates that were 6.1–173.7-fold faster than those measured for Fe(VI) alone, depending on pH, CaSO 3 dosage, and the properties of organic contaminants. Many lines of evidence verified that neither SO 4 •– nor • OH was the active species in the Fe(VI)–CaSO 3 process. The accelerating effect of CaSO 3 was ascribed to the direct generation of Fe(IV)/Fe(V) species from the reaction of Fe(VI) with soluble SO 3 2– via one-electron steps as well as the indirect generation of Fe(IV)/Fe(V) species from the self-decay of Fe(VI) and Fe(VI) reaction with H 2 O 2, which could be catalyzed by uncomplexed Fe(III). Besides, the Fe(VI)–CaSO 3 process exhibited satisfactory removal of organic contaminants in real water, and inorganic anions showed negligible effects on organic contaminant decomposition in this process. Thus, the Fe(VI)–CaSO 3 process with Fe(IV)/Fe(V) as reactive oxidants may be a promising method for abating various micropollutants in water treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Buxton, G. V., Greenstock, C. L., Helman, W. P., & Ross, A. B. (1988) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555805 · Cited by 12,332
Yang, Y., Lu, X., Jiang, J., Ma, J., Liu, G., Cao, Y., Liu, W., Li, J., Pang, S., Kong, X., et al. (2017) · Water Research · doi:10.1016/j.watres.2017.03.054 · Cited by 637
Forrester, A. R., & Hepburn, S. P. (1971) · Journal of the Chemical Society C: Organic · doi:10.1039/j39710000701 · Cited by 77
Cited by
Zong, Y., Shao, Y., Zeng, Y., Shao, B., Xu, L., Zhao, Z., Liu, W., & Wu, D. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.1c00375 · Cited by 499
Self-citationSulfite-based advanced oxidation and reduction processes for water treatment
Wu, S., Shen, L., Lin, Y., Yin, K., & Yang, C. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.128872 · Cited by 382
Li, Y., Yang, T., Qiu, S., Lin, W., Yan, J., Fan, S., & Zhou, Q. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.124382 · Cited by 365
Huang, B., Wu, Z., Wang, X., Song, X., Zhou, H., Zhang, H., Zhou, P., Liu, W., Xiong, Z., & Lai, B. (2023) · Environmental Science & Technology · doi:10.1021/acs.est.3c05509 · Cited by 281
Metadata
- Authors
- Shao, B., Dong, H., Sun, B., & Guan, X.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-12-20
- Volume
- 53
- Issue
- 2
- Pages
- 894-902
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2906035730
- Cited by
- 393
- References
- 3
- FWCI
- 9.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Role of Ferrate(IV) and Ferrate(V) in Activating Ferrate(VI) by Calcium Sulfite for Enhanced Oxidation of Organic Contaminants. https://app.cochat.ai/papers/10.1021/acs.est.8b04990
- The paper
- Shao, B., Dong, H., Sun, B., & Guan, X. (2019). Role of Ferrate(IV) and Ferrate(V) in Activating Ferrate(VI) by Calcium Sulfite for Enhanced Oxidation of Organic Contaminants. Environmental Science & Technology. https://doi.org/10.1021/acs.est.8b04990
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.