CoChat

Oxygen-Vacancy-Enhanced Peroxidase-like Activity of Reduced Co3O4 Nanocomposites for the Colorimetric Detection of H2O2 and Glucose

Lu, Jitao, Zhang, Haowen, Li, Sheng, Guo, Shanshan, Shen, Li, Zhou, Tingting, Zhong, Hua, Wu, Lu, Meng, Qingguo, Zhang, Yuexing · 2020 · Inorganic Chemistry
Cited by 192

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Colorimetric assays have drawn increasing research interest with respect to the quantitative detection of hydrogen peroxide (H 2 O 2 ) based on artificial enzymes because of their advantages with respect to natural enzymes, including design flexibility, low cost, and high stability. Regardless, the majority of the artificial enzymes exhibit low affinity to H 2 O 2 with large Michaelis–Menten constants ( K m ). This indicates that the catalytic oxidation of 3,3′,5,5′-tetramethylbenzidine (TMB) to blue-colored oxTMB requires a high H 2 O 2 concentration, hindering the sensitivity of the colorimetric assay. To address this problem, novel reduced Co 3 O 4 nanoparticles (R-Co 3 O 4 ) have been synthesized in this study via a step-by-step procedure using ZIF-67 as the precursor. R-Co 3 O 4 exhibits a considerably enhanced peroxidase-like activity when compared with that exhibited by pristine Co 3 O 4 (P-Co 3 O 4 ). The catalytic process in the case of R-Co 3 O 4 occurs in accordance with the typical Michaelis–Menten equation, and the affinity of R-Co 3 O 4 to H 2 O 2 is apparently higher than that of P-Co 3 O 4 . Furthermore, the density functional theory calculations revealed that the introduction of oxygen vacancies to R-Co 3 O 4 enhances its H 2 O 2 adsorption ability and facilitates the decomposition of H 2 O 2 to produce ·OH radicals, resulting in improved peroxidase-like activity. A simple and convenient colorimetric assay has been established based on the excellent peroxidase-like activity of R-Co 3 O 4 for detecting H 2 O 2 in concentrations of 1–30 μM with a detection limit of 4.3 × 10 –7 mol/L (S/N = 3). Furthermore, the R-Co 3 O 4 -based colorimetric method was successfully applied to glucose detection in human serum samples, demonstrating its potential for application in complex biological systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.inorgchem.9b03512

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Lu, J., Zhang, H., Li, S., Guo, S., Shen, L., Zhou, T., Zhong, H., Wu, L., Meng, Q., & Zhang, Y.
Venue
Inorganic Chemistry
Published
2020-02-11
Volume
59
Issue
5
Pages
3152-3159
ISSN
  • 0020-1669 (ISSN-L)
  • 1520-510X
OpenAlex
W3006523249
Cited by
192
References
2
FWCI
8.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.