Abstract
Four different glycerol-based deep eutectic solvents (DESs) were tested as extracting agents for the separation of the azeotropic mixture {methyl ethyl ketone + ethanol} via liquid–liquid extraction. The selected DESs for this work were: glycerol/choline chloride with molar ratios (4:1) and (2:1), and glycerol/tetramethylammonium chloride with molar ratios (4:1) and (2:1). The selected DESs have been characterized by measuring the density and the viscosity at different temperatures. The liquid–liquid equilibria data of the ternary systems {methyl ethyl ketone + ethanol + DES} were experimentally determined at T /K = 298.15 and atmospheric pressure. The extraction efficiencies of the selected DESs were analyzed by determining the solute distribution coefficients and the selectivity values, which were calculated from the experimental results. The extraction performance of the DESs was compared to the extraction data of pure glycerol. The integrity of the DESs after recovery was also studied. Finally, the experimental LLE data were regressed using the nonrandom two liquid (NRTL) model. It was found that the addition of a hydrogen bond acceptor to glycerol, and therefore, the formation of a deep eutectic solvent, improves the extraction efficiency of this mixture via liquid–liquid extraction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Natural deep eutectic solvents as new potential media for green technology
Dai, Y., van Spronsen, J., Witkamp, G.-J., Verpoorte, R., & Choi, Y. H. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.12.019 · Cited by 2,694
Low-transition-temperature mixtures (LTTMs): A new generation of designer solvents
Francisco, M., van den Bruinhorst, A., & Kroon, M. C. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201207548 · Cited by 1,378
Self-citationFrancisco, M., van den Bruinhorst, A., & Kroon, M. C. (2012) · Green Chemistry · doi:10.1039/c2gc35660k · Cited by 814
Self-citationIonic liquids and deep eutectic mixtures: Sustainable solvents for extraction processes
Pena‐Pereira, F., & Namieśnik, J. (2014) · ChemSusChem · doi:10.1002/cssc.201301192 · Cited by 432
Cited by
Extraction of polyphenolic antioxidants from orange peel waste using deep eutectic solvents
Ozturk, B., Parkinson, C., & Gonzalez-Miquel, M. (2018) · Separation and Purification Technology · doi:10.1016/j.seppur.2018.05.052 · Cited by 542
Database of deep eutectic solvents and their physical properties: A review
Omar, K. A., & Sadeghi, R. (2023) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2023.121899 · Cited by 282
Lapeña, D., Lomba, L., Artal, M., Lafuente, C., & Giner, B. (2019) · The Journal of Chemical Thermodynamics · doi:10.1016/j.jct.2018.07.031 · Cited by 129
Kaur, P., Rajani, N., Kumawat, P., Singh, N., & Kushwaha, J. P. (2018) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2017.12.013 · Cited by 78
Metadata
- Authors
- Rodriguez, N. R., Ferre Guell, J., & Kroon, M. C.
- Venue
- Journal of Chemical & Engineering Data
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-01-27
- Volume
- 61
- Issue
- 2
- Pages
- 865-872
- ISSN
- 0021-9568 (ISSN-L)
- 1520-5134
- OpenAlex
- W2267636442
- Cited by
- 67
- References
- 4
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.