Multiplatform Approach for Plasma Proteomics: Complementarity of Olink Proximity Extension Assay Technology to Mass Spectrometry-Based Protein Profiling
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
The plasma proteome is the ultimate target for biomarker discovery. It stores an endless amount of information on the pathophysiological status of a living organism, which is, however, still difficult to comprehensively access. The high complexity of the plasma proteome can be addressed by either a system-wide and unbiased tool such as mass spectrometry (LC-MS/MS) or a highly sensitive targeted immunoassay such as the proximity extension assay (PEA). To address relevant differences and important shared characteristics, we tested the performance of LC-MS/MS in the data-dependent and data-independent acquisition modes and Olink PEA to measure circulating plasma proteins in 173 human plasma samples from a Southern German population-based cohort. We demonstrated the measurement of more than 300 proteins with both LC-MS/MS approaches applied, mainly including high-abundance plasma proteins. By the use of the PEA technology, we measured 728 plasma proteins, covering a broad dynamic range with high sensitivity down to pg/mL concentrations. Then, we quantified 35 overlapping proteins with all three analytical platforms, verifying the reproducibility of data distributions, measurement correlation, and gender-based differential expression. Our work highlights the limitations and the advantages of both targeted and untargeted approaches and proves their complementary strengths. We demonstrated a significant gain in proteome coverage depth and subsequent biological insight by a combination of platforms-a promising approach for future biomarker and mechanistic studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Initiative on Precision Medicine
Collins, F. S., & Varmus, H. (2015) · New England Journal of Medicine · doi:10.1056/nejmp1500523 · Cited by 5,202
Semi-supervised learning for peptide identification from shotgun proteomics datasets
Käll, L., Canterbury, J. D., Weston, J., Noble, W. S., & MacCoss, M. J. (2007) · Nature Methods · doi:10.1038/nmeth1113 · Cited by 2,424
Genomic atlas of the human plasma proteome
Sun, B. B., Maranville, J. C., Peters, J. E., Stacey, D., Staley, J. R., Blackshaw, J., Burgess, S., Jiang, T., Paige, E., Surendran, P., et al. (2018) · Nature · doi:10.1038/s41586-018-0175-2 · Cited by 2,268
Assarsson, E., Lundberg, M., Holmquist, G., Björkesten, J., Bucht Thorsen, S., Ekman, D., Eriksson, A., Rennel Dickens, E., Ohlsson, S., Edfeldt, G., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0095192 · Cited by 1,874
Revisiting biomarker discovery by plasma proteomics
Geyer, P. E., Holdt, L. M., Teupser, D., & Mann, M. (2017) · Molecular Systems Biology · doi:10.15252/msb.20156297 · Cited by 917
Plasma Proteome Profiling to Assess Human Health and Disease
Geyer, P. E., Kulak, N. A., Pichler, G., Holdt, L. M., Teupser, D., & Mann, M. (2016) · Cell Systems · doi:10.1016/j.cels.2016.02.015 · Cited by 734
Toward an Optimized Workflow for Middle-Down Proteomics
Cristobal, A., Marino, F., Post, H., van den Toorn, H. W. P., Mohammed, S., & Heck, A. J. R. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03756 · Cited by 130
Huth, C., von Toerne, C., Schederecker, F., de las Heras Gala, T., Herder, C., Kronenberg, F., Meisinger, C., Rathmann, W., Koenig, W., Waldenberger, M., et al. (2019) · European Journal of Epidemiology · doi:10.1007/s10654-018-0475-8 · Cited by 56
Self-citationParamasivan, S., Adav, S. S., Ngan, S. C., Dalan, R., Leow, M. K.-S., Ho, H. H., & Sze, S. K. (2020) · Scientific Reports · doi:10.1038/s41598-020-62341-z · Cited by 41
Cited by
Synergistic insights into human health from aptamer- and antibody-based proteomic profiling
Pietzner, M., Wheeler, E., Carrasco-Zanini, J., Kerrison, N. D., Oerton, E., Koprulu, M., Luan, J., Hingorani, A. D., Williams, S. A., Wareham, N. J., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-27164-0 · Cited by 234
Rooney, M. R., Chen, J., Ballantyne, C. M., Hoogeveen, R. C., Tang, O., Grams, M. E., Tin, A., Ndumele, C. E., Zannad, F., Couper, D. J., et al. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvac186 · Cited by 77
Cullen, N. C., Mälarstig, A. N., Stomrud, E., Hansson, O., & Mattsson-Carlgren, N. (2021) · Scientific Reports · doi:10.1038/s41598-021-81705-7 · Cited by 62
Sissala, N., Babačić, H., Leo, I. R., Cao, X., Forshed, J., Eriksson, L. E., Lehtiö, J., Fredolini, C., Åberg, M., & Pernemalm, M. (2025) · Communications Chemistry · doi:10.1038/s42004-025-01753-2 · Cited by 25
Metadata
- Authors
- Petrera, A., von Toerne, C., Behler, J., Huth, C., Thorand, B., Hilgendorff, A., & Hauck, S. M.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-11-30
- Volume
- 20
- Issue
- 1
- Pages
- 751-762
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W3109793670
- Cited by
- 216
- References
- 9
- FWCI
- 7.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.