High Density Individually Addressable Nanowire Arrays Record Intracellular Activity from Primary Rodent and Human Stem Cell Derived Neurons
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We report a new hybrid integration scheme that offers for the first time a nanowire-on-lead approach, which enables independent electrical addressability, is scalable, and has superior spatial resolution in vertical nanowire arrays. The fabrication of these nanowire arrays is demonstrated to be scalable down to submicrometer site-to-site spacing and can be combined with standard integrated circuit fabrication technologies. We utilize these arrays to perform electrophysiological recordings from mouse and rat primary neurons and human induced pluripotent stem cell (hiPSC)-derived neurons, which revealed high signal-to-noise ratios and sensitivity to subthreshold postsynaptic potentials (PSPs). We measured electrical activity from rodent neurons from 8 days in vitro (DIV) to 14 DIV and from hiPSC-derived neurons at 6 weeks in vitro post culture with signal amplitudes up to 99 mV. Overall, our platform paves the way for longitudinal electrophysiological experiments on synaptic activity in human iPSC based disease models of neuronal networks, critical for understanding the mechanisms of neurological diseases and for developing drugs to treat them.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multi-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
Patolsky, F., Timko, B. P., Yu, G., Fang, Y., Greytak, A. B., Zheng, G., & Lieber, C. M. (2006) · Science · doi:10.1126/science.1128640 · Cited by 832
Distal Initiation and Active Propagation of Action Potentials in Interneuron Dendrites
Martina, M., Vida, I., & Jonas, P. (2000) · Science · doi:10.1126/science.287.5451.295 · Cited by 375
Cited by
A nanoelectrode array for obtaining intracellular recordings from thousands of connected neurons
Abbott, J., Ye, T., Krenek, K., Gertner, R. S., Ban, S., Kim, Y., Qin, L., Wu, W., Park, H., & Ham, D. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0455-7 · Cited by 272
Bioinspired bio-voltage memristors
Fu, T., Liu, X., Gao, H., Ward, J. E., Liu, X., Yin, B., Wang, Z., Zhuo, Y., Walker, D. J. F., Joshua Yang, J., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-15759-y · Cited by 257
Metadata
- Authors
- Liu, R., Chen, R., Elthakeb, A. T., Lee, S. H., Hinckley, S., Khraiche, M. L., Scott, J., Pre, D., Hwang, Y., Tanaka, A., Ro, Y. G., Matsushita, A. K., Dai, X., Soci, C., Biesmans, S., James, A., Nogan, J., Jungjohann, K. L., Pete, D. V., Webb, D. B., Zou, Y., Bang, A. G., & Dayeh, S. A.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-04-10
- Volume
- 17
- Issue
- 5
- Pages
- 2757-2764
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2605023718
- Cited by
- 176
- References
- 3
- FWCI
- 6.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High Density Individually Addressable Nanowire Arrays Record Intracellular Activity from Primary Rodent and Human Stem Cell Derived Neurons. https://app.cochat.ai/papers/10.1021/acs.nanolett.6b04752
- The paper
- Liu, R., Chen, R., Elthakeb, A. T., Lee, S. H., Hinckley, S., Khraiche, M. L., Scott, J., Pre, D., Hwang, Y., Tanaka, A., Ro, Y. G., Matsushita, A. K., Dai, X., Soci, C., Biesmans, S., James, A., Nogan, J., Jungjohann, K. L., Pete, D. V., . . . Dayeh, S. A. (2017). High Density Individually Addressable Nanowire Arrays Record Intracellular Activity from Primary Rodent and Human Stem Cell Derived Neurons. Nano Letters. https://doi.org/10.1021/acs.nanolett.6b04752
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.