Assessment of Gold Nanoparticle-Mediated-Enhanced Hyperthermia Using MR-Guided High-Intensity Focused Ultrasound Ablation Procedure
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
High-intensity focused ultrasound (HIFU) has gained increasing popularity as a noninvasive therapeutic procedure to treat solid tumors. However, collateral damage due to the use of high acoustic powers during HIFU procedures remains a challenge. The objective of this study is to assess the utility of using gold nanoparticles (gNPs) during HIFU procedures to locally enhance heating at low powers, thereby reducing the likelihood of collateral damage. Phantoms containing tissue-mimicking material (TMM) and physiologically relevant concentrations (0%, 0.0625%, and 0.125%) of gNPs were fabricated. Sonications at acoustic powers of 10, 15, and 20 W were performed for a duration of 16 s using an MR-HIFU system. Temperature rises and lesion volumes were calculated and compared for phantoms with and without gNPs. For an acoustic power of 10 W, the maximum temperature rise increased by 32% and 43% for gNPs concentrations of 0.0625% and 0.125%, respectively, when compared to the 0% gNPs concentration. For the power of 15 W, a lesion volume of 0, 44.5 ± 7, and 63.4 ± 32 mm 3 was calculated for the gNPs concentration of 0%, 0.0625%, and 0.125%, respectively. For a power of 20 W, it was found that the lesion volume doubled and tripled for concentrations of 0.0625% and 0.125% gNPs, respectively, when compared to the concentration of 0% gNPs. We conclude that gNPs have the potential to locally enhance the heating and reduce damage to healthy tissue during tumor ablation using HIFU.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exploiting the enhanced permeability and retention effect for tumor targeting
Iyer, A. K., Khaled, G., Fang, J., & Maeda, H. (2006) · Drug Discovery Today · doi:10.1016/j.drudis.2006.07.005 · Cited by 1,846
Cited by
Zhang, C., Yan, K., Fu, C., Peng, H., Hawker, C. J., & Whittaker, A. K. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00632 · Cited by 493
Synthesis and Biomedical Applications of Multifunctional Nanoparticles
Kim, D., Shin, K., Kwon, S. G., & Hyeon, T. (2018) · Advanced Materials · doi:10.1002/adma.201802309 · Cited by 317
Advanced Nanotechnology Leading the Way to Multimodal Imaging‐Guided Precision Surgical Therapy
Wang, C., Fan, W., Zhang, Z., Wen, Y., Xiong, L., & Chen, X. (2019) · Advanced Materials · doi:10.1002/adma.201904329 · Cited by 213
Li, S., Tan, L., & Meng, X. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201908924 · Cited by 193
Chen, Y., Du, M., Yuan, Z., Chen, Z., & Yan, F. (2022) · Nature Communications · doi:10.1038/s41467-022-31932-x · Cited by 189
“In contrast, ultrasound has many advantages in noninvasiveness, safety and tissue penetration 22 – 24 .”
Background
Metadata
- Authors
- Devarakonda, S. B., Myers, M. R., Lanier, M., Dumoulin, C., & Banerjee, R. K.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-03-16
- Volume
- 17
- Issue
- 4
- Pages
- 2532-2538
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2595628435
- Cited by
- 85
- References
- 1
- FWCI
- 4.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.