Fast, Background-Free DNA-PAINT Imaging Using FRET-Based Probes
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
DNA point accumulation in nanoscale topography (DNA-PAINT) enables super-resolution microscopy by harnessing the predictable, transient hybridization between short dye-labeled "imager" and complementary target-bound "docking" strands. DNA-PAINT microscopy allows sub-5 nm spatial resolution, spectrally unlimited multiplexing, and quantitative image analysis. However, these abilities come at the cost of nonfluorogenic imager strands, also emitting fluorescence when not bound to their docking strands. This has thus far prevented rapid image acquisition with DNA-PAINT, as the blinking rate of probes is limited by an upper-bound of imager strand concentrations, which in turn is dictated by the necessity to facilitate the detection of single-molecule binding events over the background of unbound, freely diffusing probes. To overcome this limitation and enable fast, background-free DNA-PAINT microscopy, we here introduce FRET-based imaging probes, alleviating the concentration-limit of imager strands and speeding up image acquisition by several orders of magnitude. We assay two approaches for FRET-based DNA-PAINT (or FRET-PAINT) using either fixed or transient acceptor dyes in combination with transiently binding donor-labeled DNA strands and achieve high-quality super-resolution imaging on DNA origami structures in a few tens of seconds. Finally, we also demonstrate the applicability of FRET-PAINT in a cellular environment by performing super-resolution imaging of microtubules in under 30 s. FRET-PAINT combines the advantages of conventional DNA-PAINT with fast image acquisition times, facilitating the potential study of dynamic processes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Super-resolution microscopy with DNA-PAINT
Schnitzbauer, J., Strauss, M. T., Schlichthaerle, T., Schueder, F., & Jungmann, R. (2017) · Nature Protocols · doi:10.1038/nprot.2017.024 · Cited by 1,047
Self-citation
Cited by
Single-molecule localization microscopy
Lelek, M., Gyparaki, M. T., Beliu, G., Schueder, F., Griffié, J., Manley, S., Jungmann, R., Sauer, M., Lakadamyali, M., & Zimmer, C. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00038-x · Cited by 954
Self-citationSwitchable Fluorophores for Single-Molecule Localization Microscopy
Li, H., & Vaughan, J. C. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00767 · Cited by 319
Lerner, E., Barth, A., Hendrix, J., Ambrose, B., Birkedal, V., Blanchard, S. C., Börner, R., Sung Chung, H., Cordes, T., Craggs, T. D., et al. (2021) · eLife · doi:10.7554/elife.60416 · Cited by 296
Fluorescent Nanoparticles for Super-Resolution Imaging
Li, W., Kaminski Schierle, G. S., Lei, B., Liu, Y., & Kaminski, C. F. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00050 · Cited by 278
FÖrster resonance energy transfer (FRET)-based biosensors for biological applications
Zhang, X., Hu, Y., Yang, X., Tang, Y., Han, S., Kang, A., Deng, H., Chi, Y., Zhu, D., & Lu, Y. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.05.019 · Cited by 234
FRET Based Biosensor: Principle Applications Recent Advances and Challenges
Verma, A. K., Noumani, A., Yadav, A. K., & Solanki, P. R. (2023) · Diagnostics · doi:10.3390/diagnostics13081375 · Cited by 202
Super-resolution microscopy as a powerful tool to study complex synthetic materials
Pujals, S., Feiner-Gracia, N., Delcanale, P., Voets, I., & Albertazzi, L. (2019) · Nature Reviews Chemistry · doi:10.1038/s41570-018-0070-2 · Cited by 197
Förster resonance energy transfer (FRET) and applications thereof
Kaur, A., Kaur, P., & Ahuja, S. (2020) · Analytical Methods · doi:10.1039/d0ay01961e · Cited by 180
Seeing beyond the limit: A guide to choosing the right super-resolution microscopy technique
Valli, J., Garcia-Burgos, A., Rooney, L. M., Vale de Melo e Oliveira, B., Duncan, R. R., & Rickman, C. (2021) · Journal of Biological Chemistry · doi:10.1016/j.jbc.2021.100791 · Cited by 159
“Newer applications of smFRET use quantum dot–based FRET nanosensors (104, 105) or SMLMlike blinking methods such as photoactivatable (106) or PAINT-based FRET probes (107, 108) to enable single molecule–level detection.”
MethodDanial, J. S. H., Lam, J. Y. L., Wu, Y., Woolley, M., Dimou, E., Cheetham, M. R., Emin, D., & Klenerman, D. (2022) · Nature Protocols · doi:10.1038/s41596-022-00730-6 · Cited by 40
Can DyeCycling break the photobleaching limit in single-molecule FRET?
Vermeer, B., & Schmid, S. (2022) · Nano Research · doi:10.1007/s12274-022-4420-5 · Cited by 25
Metadata
- Authors
- Auer, A., Strauss, M. T., Schlichthaerle, T., & Jungmann, R.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-09-21
- Volume
- 17
- Issue
- 10
- Pages
- 6428-6434
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2751401708
- Cited by
- 129
- References
- 2
- FWCI
- 4.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.