Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 233

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Ultrasensitive Monolayer MoS2 Field-Effect Transistor Based DNA Sensors for Screening of Down Syndrome

Liu, Jingxia, Chen, Xihua, Wang, Qinqin, Xiao, Mengmeng, Zhong, Donglai, Sun, Wei, Zhang, Guangyu, Zhang, Zhiyong·2019·Nano Letters

Abstract

Field-effect transistor (FET) biosensors based on low-dimensional materials present the advantages of low cost, high speed, small size, and excellent compatibility with integrated circuits (ICs). In this work, we fabricated highly sensitive FET-based DNA biosensors based on chemical vapor deposition (CVD)-grown monolayer MoS 2 films in batches and explored their application in noninvasive prenatal testing (NIPT) for trisomy 21 syndrome. Specifically, MoS 2 was functionalized with gold nanoparticles (Au NPs) of an optimized size and at an ideal density, and then, probe DNAs for the specific capture of target DNAs were immobilized on the nanoparticles. The fabricated FET biosensors are able to reliably detect target DNA fragments (chromosome 21 or 13) with a detection limit below 100 aM, a high response up to 240%, and a high specificity, which satisfy the requirement for the screening of Down syndrome. In addition, a real-time test was conducted to show that the biosensor clearly responds to the target DNA at concentrations as low as 1 fM. Our approach shows the potential for detecting the over-expression of chromosome 21 in the peripheral blood of pregnant women and achieving Down syndrome screening.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.nanolett.8b03818

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 233

Metadata

Authors
Liu, J., Chen, X., Wang, Q., Xiao, M., Zhong, D., Sun, W., Zhang, G., & Zhang, Z.
Venue
Nano Letters
Published
2019-02-13
Volume
19
Issue
3
Pages
1437-1444
ISSN
  • 1530-6984 (ISSN-L)
  • 1530-6992
OpenAlex
W2912956955
Cited by
233
References
3
FWCI
8.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasensitive Monolayer MoS2 Field-Effect Transistor Based DNA Sensors for Screening of Down Syndrome. https://app.cochat.ai/papers/10.1021/acs.nanolett.8b03818
The paper
Liu, J., Chen, X., Wang, Q., Xiao, M., Zhong, D., Sun, W., Zhang, G., & Zhang, Z. (2019). Ultrasensitive Monolayer MoS2 Field-Effect Transistor Based DNA Sensors for Screening of Down Syndrome. Nano Letters. https://doi.org/10.1021/acs.nanolett.8b03818

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.