The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Highly Wearable, Breathable, and Washable Sensing Textile for Human Motion and Pulse Monitoring
Abstract
At present, pressure sensor textiles are of great significance in the area of wearable electronics, especially for making smart or intelligent textiles. However, the design of these textile-based devices with sensitive ability, simple fabrication, and low cost is still challenging. In this study, we developed a triboelectric sensing textile constructed with core–shell yarns. Nylon filament and polytetrafluoroethylene filament were selected as the positive and negative layers, respectively, in the woven structure while the built-in helical stainless steel yarn was serving as the inner electrode layer. The sensitivity of the sensing textile can reach up to 1.33 V·kPa –1 and 0.32 V·kPa –1 in the pressure range of 1.95–3.13 kPa and 3.20–4.61 kPa, respectively. This sensing textile presented good mechanical stability and sensing capability even after 4200 cycles of continuous operation or after 4 h continuous water washing. Benefiting from the favorable merits of being highly flexible, breathable, lightweight, and even dyeable, the fabricated device was capable of being placed on any desired body parts for quantifying the dynamic human motions. It can be effectively used to measure and monitor various human movements associated with different joints, such as the hand, elbow, knee, and underarm. Moreover, the sensing textile was able to capture real-time pulse signals and reflect the current health status for human beings. This study affords an innovative and promising track for multifunctional pressure sensor textiles with wide applications in smart textiles and personalized healthcare.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Movement toward a novel activity monitoring device
Montgomery-Downs, H. E., Insana, S. P., & Bond, J. A. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0585-y · Cited by 301
Cited by
Luo, J., Gao, S., Luo, H., Wang, L., Huang, X., Guo, Z., Lai, X., Lin, L., Li, R. K. Y., & Gao, J. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.126898 · Cited by 483
Liu, X., Miao, J., Fan, Q., Zhang, W., Zuo, X., Tian, M., Zhu, S., Zhang, X., & Qu, L. (2022) · Advanced Fiber Materials · doi:10.1007/s42765-021-00126-3 · Cited by 350
Wearable Soft Technologies for Haptic Sensing and Feedback
Yin, J., Hinchet, R., Shea, H., & Majidi, C. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202007428 · Cited by 325
Design, manufacturing and applications of wearable triboelectric nanogenerators
Wang, H., Han, M., Song, Y., & Zhang, H. (2021) · Nano Energy · doi:10.1016/j.nanoen.2020.105627 · Cited by 179
Metadata
- Authors
- Lou, M., Abdalla, I., Zhu, M., Wei, X., Yu, J., Li, Z., & Ding, B.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-04-10
- Volume
- 12
- Issue
- 17
- Pages
- 19965-19973
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W3015602432
- Cited by
- 173
- References
- 1
- FWCI
- 8.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Wearable, Breathable, and Washable Sensing Textile for Human Motion and Pulse Monitoring. https://app.cochat.ai/papers/10.1021/acsami.0c03670
- The paper
- Lou, M., Abdalla, I., Zhu, M., Wei, X., Yu, J., Li, Z., & Ding, B. (2020). Highly Wearable, Breathable, and Washable Sensing Textile for Human Motion and Pulse Monitoring. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.0c03670
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.