CoChat

Movement toward a novel activity monitoring device

Montgomery-Downs, Hawley E., Insana, Salvatore P., Bond, Jonathan A. · 2012 · Sleep and Breathing

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Purpose Although polysomnography is necessary for diagnosis of most sleep disorders, it is also expensive, time-consuming, intrusive, and interferes with sleep. Field-based activity monitoring is increasingly used as an alternative measure that can be used to answer certain clinical and research questions. The purpose of this study was to evaluate the reliability and validity of a novel activity monitoring device (Fitbit) compared to both polysomnography and standard actigraphy (Actiwatch-64). Methods To test validity, simultaneous Fitbit and actigraph were worn during standard overnight polysomnography by 24 healthy adults at the West Virginia University sleep research laboratory. To test inter-Fitbit reliability, three participants also wore two of the Fitbit devices overnight at home. Results Fitbit showed high intradevice reliability = 96.5-99.1. Fitbit and actigraph differed significantly on recorded total sleep time and sleep efficiency between each other and polysomnography. Bland-Altman plots indicated that both Fitbit and actigraph overestimated sleep efficiency and total sleep time. Sensitivity of both Fitbit and actigraphy for accurately identifying sleep was high within all sleep stages and during arousals; specificity of both Fitbit and actigraph for accurately identifying wake was poor. Specificity of actigraph was higher except for wake before sleep onset; sensitivity of Fitbit was higher in all sleep stages and during arousals. Conclusions The web-based Fitbit…

Overview

Integrity signals

Registry

Crossref · 10.1007/s11325-011-0585-y

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 6 references

Cited by

See all 321

Metadata

Authors
Montgomery-Downs, H. E., Insana, S. P., & Bond, J. A.
Affiliations
West Virginia University (US)
Venue
Sleep and Breathing
Published
2011-10-06
Volume
16
Issue
3
Pages
913-917
ISSN
  • 1520-9512 (ISSN-L)
  • 1522-1709
OpenAlex
W2112783455
Cited by
301
References
6
Citations by year
2026: 3 · 2025: 9 · 2024: 16 · 2023: 10 · 2022: 25 · 2021: 17 · 2020: 29 · 2019: 51 · 2018: 29 · 2017: 33 · 2016: 26 · 2015: 28 · 2014: 16 · 2013: 4 · 2012: 5
FWCI
10.30
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Sleep And Breathing (publishedVersion)
  • PubMed (publishedVersion)
Funders
West Virginia University
Topics
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Circadian rhythm and melatonin
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
Keywords
Fitbit, activity monitoring, actigraphy, polysomnography, sleep efficiency, total sleep time, device reliability, device validity, sleep disorders, wearable devices
MeSH terms
Adult, Arousal, Equipment Design, Female, Humans, Male, Signal Processing, Computer-Assisted, Sleep Wake Disorders, Sleep Stages, Wakefulness, Reproducibility of Results, Polysomnography, Monitoring, Ambulatory, Young Adult, Actigraphy, Accelerometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Movement toward a novel activity monitoring device. https://app.cochat.ai/papers/10.1007/s11325-011-0585-y
The paper
Montgomery-Downs, H. E., Insana, S. P., & Bond, J. A. (2012). Movement toward a novel activity monitoring device. Sleep and Breathing. https://doi.org/10.1007/s11325-011-0585-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.