The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
3D Printing of Highly Sensitive and Large-Measurement-Range Flexible Pressure Sensors with a Positive Piezoresistive Effect
Abstract
Piezoresistive composite-based flexible pressure sensors often suffer from a trade-off between the sensitivity and measurement range. Moreover, the sensitivity or measurement range is theoretically limited owing to the negative piezoresistive coefficient, resulting in resistance variation below 100%. Here, flexible pressure sensors were fabricated using the three-dimensional (3D) printing technique to improve both the sensitivity and sensing range through the positive piezoresistive effect. With the addition of carbon nanotubes (CNTs) and fumed silica nanoparticles (SiNPs) as a conductive filler and rheology modifier, respectively, the viscoelastic silicone rubber solution converted to a printable gel ink. Soft and porous composites (SPCs) were then directly printed in air at room temperature. The sensitivity and sensing range of the SPC-based pressure sensor can be simultaneously tuned by adjusting the conducting CNT and insulating SiNP contents. By optimizing the density of the CNT conductive network in the matrix, positive piezoresistive sensitivity (+0.096 kPa –1 ) and a large linear sensing range (0–175 kPa) were obtained. To demonstrate potential applications, the completely soft SPC-based sensor was successfully used in grasp sensing and gait monitoring systems. The 3D printed sensors were also assembled as a smart artificial sensory array to map the pressure distribution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trung, T. Q., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504244 · Cited by 2,160
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
A flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres
Pang, C., Lee, G.-Y., Kim, T.-I., Kim, S. M., Kim, H. N., Ahn, S.-H., & Suh, K.-Y. (2012) · Nature Materials · doi:10.1038/nmat3380 · Cited by 1,695
Park, J., Lee, Y., Hong, J., Ha, M., Jung, Y.-D., Lim, H., Kim, S. Y., & Ko, H. (2014) · ACS Nano · doi:10.1021/nn500441k · Cited by 915
Pang, Y., Tian, H., Tao, L., Li, Y., Wang, X., Deng, N., Yang, Y., & Ren, T.-L. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b08172 · Cited by 456
Cited by
Fiber/Yarn and Textile-Based Piezoresistive Pressure Sensors
Yang, Y., Liu, Y., & Yin, R. (2025) · Advanced Fiber Materials · doi:10.1007/s42765-024-00479-5 · Cited by 110
“…sophisticated microstructures, such as bridge-cell micro-structured conductive coatings [33], or directly 3D printing cellular composites with crossing filaments that have tunable piezoresistivity (positive or negative) due to the joint effect of contact resistance and bulk resistance change [167].”
Sharma, A., Ansari, M. Z., & Cho, C. (2022) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2022.113934 · Cited by 95
Metadata
- Authors
- Tang, Z., Jia, S., Zhou, C., & Li, B.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-05-29
- Volume
- 12
- Issue
- 25
- Pages
- 28669-28680
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W3029425478
- Cited by
- 215
- References
- 5
- FWCI
- 8.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.