CoChat
Cited by 217

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Rapid Fabrication of a Flexible and Transparent Ag Nanocubes@PDMS Film as a SERS Substrate with High Performance

Li, Limin, Chin, Wee Shong · 2020 · ACS Applied Materials & Interfaces

Abstract

Flexible and transparent surface-enhanced Raman scattering (SERS) substrates have long been sought-after for nondestructive detection of analytes on nonplanar surfaces, but there is still a lack of one convenient and robust way to fabricate such SERS substrates rapidly. Herein, we demonstrate the fabrication of a high-performance SERS substrate consisting of plasmonic Ag nanocube (Ag NC) arrays anchored onto a flexible transparent poly(dimethylsiloxane) (PDMS) membrane. Through a simple organic/water interfacial self-assembly method, arrays of presynthesized Ag NCs are obtained and directly retrieved onto the PDMS membrane without the aid of rigid substrates (e.g., Si wafers or glass slides). The plasmonic Ag NC arrays can produce strong electromagnetic enhancement, achieving high SERS enhancement factor (∼3.43 × 10 6 ) and ideal detection capability for methylene blue (MB) and Rhodamine 6G (R6G) at respective trace amounts of 10 –10 and 10 –9 M. Moreover, without the need to transfer from substrate to substrate, the regular Ag NC arrays are kept intact, thereby yielding a good reproducibility (RSD ∼12%). We demonstrate further that our as-fabricated SERS substrate displays ideal selectivity toward different kinds of analyte molecules (R6G, crystal violet (CV), and MB) based on principal component analysis. The PDMS membrane owns excellent transparency and flexibility; thus, the substrate enables the conformal contact with nonplanar surfaces and allows the penetration of a laser to reach the analytes from the reverse side of the substrate. This thus facilitates in situ SERS detection of trace residual crystal violet on fish skin, with limit of detection (LOD) reaching 0.6 ppm. This fabrication method reported here is economical and easily implemented. The robust Ag NCs@PDMS could be readily prepared and stored to meet diverse SERS sensing applications, especially for in situ detection of analytes on irregular nonplanar surfaces.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.0c07178

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Li, L., & Chin, W. S.
Venue
ACS Applied Materials & Interfaces
Published
2020-07-23
Volume
12
Issue
33
Pages
37538-37548
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W3044604386
Cited by
217
References
1
FWCI
18.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.