Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 172

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

MXene-Coated Air-Permeable Pressure-Sensing Fabric for Smart Wear

Liu, Rui, Li, Jianmin, Li, Meng, Zhang, Qinghong, Shi, Guoying, Li, Yaogang, Hou, Chengyi, Wang, Hongzhi·2020·ACS Applied Materials & Interfaces

Abstract

Abstract Considering the fast development of wearable electronics and soft robotics, pressure sensors with high sensitivity, durability, and washability are of great importance. However, the surface modification of fabrics with high-sensitivity active materials requires that issues associated with poor interface adhesion and stability are resolved. In this study, we explored the key factors for firmly bonding MXene to fabric substrates to fabricate wearable and washable pressure sensing fabric. The interactions between MXene and various fabrics were elucidated by investigating the adsorption and binding capacities. The natural rough surface of cotton fibers also promoted the firm adsorption of MXene. As a result, MXene was difficult to detach, even with mechanical washing and ultrasonic treatment. Further, the abundant functional groups on the MXene surface were conducive to interfacial interactions with cotton fibers. An increase in the amount of fluorine-containing functional groups also improved the hydrophobicity of the fabric surface. The good force-sensitive resistance of MXene-coated cotton allowed this pressure-sensing fabric to function as a flexible pressure sensor, which showed a high gauge factor (7.67 kPa–1), a rapid response and relaxation speed (<35 ms), excellent stability (>2000 cycles), and good washing durability. Further, the as-fabricated flexible pressure sensor was demonstrated as a wearable human–machine interface that supported multitouch interactions and exhibited a rapid response. Thus, this work provides a new approach for developing next-generation high-sensitivity wearable pressure sensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.0c11715

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 172

Metadata

Authors
Liu, R., Li, J., Li, M., Zhang, Q., Shi, G., Li, Y., Hou, C., & Wang, H.
Venue
ACS Applied Materials & Interfaces
Published
2020-09-21
Volume
12
Issue
41
Pages
46446-46454
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W3087711394
Cited by
172
References
5
FWCI
7.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MXene-Coated Air-Permeable Pressure-Sensing Fabric for Smart Wear. https://app.cochat.ai/papers/10.1021/acsami.0c11715
The paper
Liu, R., Li, J., Li, M., Zhang, Q., Shi, G., Li, Y., Hou, C., & Wang, H. (2020). MXene-Coated Air-Permeable Pressure-Sensing Fabric for Smart Wear. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.0c11715

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.