Cited by 2,042Advanced Sensor and Energy Harvesting MaterialsOrganic Electronics and PhotovoltaicsConducting polymers and applications

Flexible polymer transistors with high pressure sensitivity for application in electronic skin and health monitoring

Open access
Schwartz, Gregor, Tee, Benjamin C.-K., Mei, Jianguo, Appleton, Anthony L., Kim, Do Hwan, Wang, Huiliang, Bao, Zhenan·2013·Nature Communications

Abstract

Flexible pressure sensors are essential parts of an electronic skin to allow future biomedical prostheses and robots to naturally interact with humans and the environment. Mobile biomonitoring in long-term medical diagnostics is another attractive application for these sensors. Here we report the fabrication of flexible pressure-sensitive organic thin film transistors with a maximum sensitivity of 8.4 kPa(-1), a fast response time of <10 ms, high stability over >15,000 cycles and a low power consumption of <1 mW. The combination of a microstructured polydimethylsiloxane dielectric and the high-mobility semiconducting polyisoindigobithiophene-siloxane in a monolithic transistor design enabled us to operate the devices in the subthreshold regime, where the capacitance change upon compression of the dielectric is strongly amplified. We demonstrate that our sensors can be used for non-invasive, high fidelity, continuous radial artery pulse wave monitoring, which may lead to the use of flexible pressure sensors in mobile health monitoring and remote diagnostics in cardiovascular medicine.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/ncomms2832

Cites

48 of 48 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Capacitive integration uses pressure-sensitive capacitors directly as gate capacitors, translating capacitance change into drain current variation in FET-based devices.

    “As shown in Figure 4I, capacitive integration uses primarily pressure-sensitive capacitors directly as gate capacitors, where the change in capacitance is translated into a variation in drain current in the field-effect transistor (FET)-based device.[102,130–132]”

    From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [130]

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z.
Affiliations
  • Stanford University (US)
  • Soongsil University (KR)
Corresponding author
Bao, Zhenan
Venue
Nature Communications
Published
2013-05-14
Volume
4
Issue
1
Pages
1859-1859
ISSN
2041-1723 (ISSN-L)
OpenAlex
W2069137854
Cited by
2,042
References
48
Citations by year
2026: 52 · 2025: 114 · 2024: 118 · 2023: 139 · 2022: 168 · 2021: 207 · 2020: 200 · 2019: 258 · 2018: 224 · 2017: 200 · 2016: 149 · 2015: 118 · 2014: 79 · 2013: 15
FWCI
66.44
Type
journal article
Language
en
Open access
Locations
  • Nature Communications (publishedVersion)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
Funders
  • National Science Foundation (1101901)
  • Camille and Henry Dreyfus Foundation
  • Deutsche Forschungsgemeinschaft
  • Division of Electrical, Communications and Cyber Systems
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Organic Electronics and Photovoltaics
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
Keywords
flexible pressure sensors, organic thin-film transistors, electronic skin, subthreshold operation, health monitoring, low power consumption, cycling stability
MeSH terms
Adult, Electronics, Medical, Equipment and Supplies, Equipment Design, Health, Humans, Microscopy, Electron, Scanning, Monitoring, Physiologic, Polymers, Pressure, Pulse, Time Factors, Transistors, Electronic, Radial Artery, Pliability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review