Antimicrobial Wound Dressings against Fluorescent and Methicillin-Sensitive Intracellular Pathogenic Bacteria

Open access
Garcia-Salinas, Sara, Gámez, Enrique, Landa, Guillermo, Arruebo, Manuel, Irusta, Silvia, Mendoza, Gracia·2020·ACS Applied Materials & Interfaces

Abstract

There is limited evidence indicating that drug-eluting dressings are clinically more effective than simple conventional dressings. To shed light on this concern, we have performed evidence-based research to evaluate the antimicrobial action of thymol (THY)-loaded antimicrobial dressings having antibiofilm forming ability, able to eradicate intracellular and extracellular pathogenic bacteria. We have used four different Staphylococcus aureus strains, including the ATCC 25923 strain, the Newman strain (methicillin-sensitive strain, MSSA) expressing the coral green fluorescent protein from the vector pCN47, and two clinical reference strains, Newman-(MSSA) and USA300-(methicillin-resistant strain), as traceable models of pathogenic bacteria commonly infecting skin and soft tissues. Compared to non-loaded dressings, THY-loaded polycaprolactone-based electrospun dressings were also able to eliminate pathogenic bacteria in coculture models based on infected murine macrophages. In addition, by using confocal microscopy and the conventional microdilution plating method, we corroborated the successful ability of THY in preventing also biofilm formation. Herein, we demonstrated that the use of wound dressings loaded with the natural monoterpenoid phenol derivative THY are able to eliminate biofilm formation and intracellular methicillin-sensitive S aureus more efficiently than with their corresponding THY-free counterparts.

Checked 2026-11-15 · 1 reference not checked yet

Overview

CoChat Summary

TL;DR

Thymol-loaded polycaprolactone electrospun wound dressings eliminated planktonic, biofilm, and intracellular methicillin-sensitive *Staphylococcus aureus* more effectively than THY-free PCL controls, including in infected J774 macrophage co-cultures. The dressings also reduced biofilm formation/eradication, while showing dose-dependent cytotoxicity to macrophages that was mitigated by short contact times.

Key findings

  • THY-loaded PCL fibers had mean diameters of 794 ± 96 nm vs 779 ± 86 nm for PCL; THY loading was 8.2 ± 0.9 wt.% with encapsulation efficiency 40.8 ± 4.6 wt.%; 30% of encapsulated THY was released in the first hour, and Peppas–Sahlin fitting gave R² = 0.993 with Fickian diffusion predominant (K1 >> K2).
  • Against cGFP-expressing *S. aureus*, free THY had MIC 0.05 mg/mL and MBC 0.15 mg/mL; 10 mg PCL-THY reached MIC, reducing growth from 10⁹ to 10⁶ CFU/mL, and 12 mg PCL-THY reached MBC in agar (0.1 mg/mL THY released in 24 h) against 10⁵ CFU.
  • Antibiofilm activity: 5 mg PCL-THY for 24 h reduced bacterial attachment, and 7 mg eliminated already formed biofilms; for ATCC 25923, 10 mg inhibited growth to 10⁷ CFU/mL and 30 mg completely eliminated biofilm, while clinical Newman-MSSA and USA300-MRSA were significantly reduced at 30 mg to 10⁴ and 10⁸ CFU/mL, respectively, vs ~10¹⁰ CFU/mL for THY-free controls.
  • Cytotoxicity: 5 mg PCL-THY (0.06 mg/mL THY) gave 80% J774 macrophage viability after 24 h (non-cytotoxic), while 7 mg gave 50% growth inhibition (0.09 mg/mL THY); 10 and 12 mg for 1 h gave >70% viability (0.12 and 0.14 mg/mL THY). In co-culture, 5–7 mg for 24 h and 10–12 mg for 1 h reduced intracellular bacteria, with 12 mg for 1 h totally reducing bacteria.

Methods

  • Electrospun PCL and THY-loaded PCL nanofibers were prepared with 20 w/w% THY relative to PCL; characterized by SEM, GC-MS for drug loading, UPLC for release, and Peppas–Sahlin release kinetics.
  • Antimicrobial testing used four *S. aureus* strains (ATCC 25923, cGFP-expressing MSSA, Newman-MSSA, USA300-MRSA) with microdilution MIC/MBC for free THY and ASTM E-2180-18 for patches; biofilm assays used confocal microscopy with Calcofluor White and CFU plating.
  • J774 macrophage cytotoxicity was measured by MTT assay, and an in vitro co-culture infection model with GFP-expressing *S. aureus* was visualized by confocal microscopy; one-way ANOVA with Dunnett’s post-test was used, with significance at p ≤ 0.05.

Limitations

  • Paper-stated caveats: the low encapsulation efficiency (40.8 ± 4.6 wt.%) was attributed to the rotating collector and evaporation of the monoterpenoid phenol derivative; the toxicity mechanism of THY is poorly understood; and free THY vs patch comparisons were confounded by liquid TSB vs solid TSA methods.
  • Evident from the text: all antimicrobial, biofilm, and infection data are in vitro (planktonic, biofilm, J774 co-culture), with no in vivo or clinical validation reported; the dressings showed dose-dependent cytotoxicity to eukaryotic macrophages, requiring short contact times or lower amounts to maintain >70% viability.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1021/acsami.0c17043

Cites

62 of 63 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 0 Not valid · 55 Not checked · 52 Own results and interpretations

44 more claims

Create a free account to see all 107 claims and to verify the 67 references still open.

See all claims — free account
  • It may state two separate claims as one. 35
  • The quote only partly states this claim. 1
  • Probably not a substantial claim. 29

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

2 of 2

Citations

Cites

Show all 62 references

Research works printed but not linked: 2

  1. Adeli-Sardou M., 2018, Biomacromol. J., 4, 46
  2. Cutting K. F., 2005, Ostomy/Wound Manag., 51, 28

Cited by

Metadata

Authors
Garcia-Salinas, S., Gámez, E., Landa, G., Arruebo, M., Irusta, S., & Mendoza, G.
Affiliations
  • Department of Chemical Engineering, Aragon Institute of Nanoscience (INA), University of Zaragoza, Campus Río Ebro-Edificio I+D, C/Mariano Esquillor S/N, 50018 Zaragoza, Spain
  • Universidad de Zaragoza (ES)
Corresponding author
Irusta, Silvia
Venue
ACS Applied Materials & Interfaces
Published
2020-11-04
Volume
12
Issue
46
Pages
51302-51313
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W3095777201
Cited by
19
References
62
Citations by year
2026: 2 · 2025: 2 · 2024: 3 · 2023: 2 · 2022: 5 · 2021: 5
FWCI
2.68
Type
journal article
Language
en
Open access
Locations
  • ACS Applied Materials & Interfaces (publishedVersion)
  • PubMed (publishedVersion)
  • Zaguan (University of Zaragoza Repository) (submittedVersion)
  • DIGITAL.CSIC (Spanish National Research Council (CSIC)) (submittedVersion)
Funders
  • Ministerio de Ciencia, Innovaci?n y Universidades (BES-2015-073735)
  • European Regional Development Fund
  • Ministerio de Econom?a y Competitividad (CTQ2017-84473-R)
  • Instituto de Salud Carlos III (MS19/00092)
Topics
  • Health Sciences › Medicine › Surgery › Wound Healing and Treatments
  • Life Sciences › Immunology and Microbiology › Applied Microbiology and Biotechnology › Antimicrobial agents and applications
  • Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
Keywords
antimicrobial dressings, thymol, Staphylococcus aureus, methicillin-susceptible Staphylococcus aureus, methicillin-resistant Staphylococcus aureus, biofilm formation, intracellular bacteria, infected macrophages, skin and soft tissue infections
MeSH terms
Animals, Anti-Bacterial Agents, Bandages, Cell Line, Macrophages, Methicillin, Microbial Sensitivity Tests, Polyesters, Staphylococcus aureus, Thymol, Biofilms, Microscopy, Confocal, Mice

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-15, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-15 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.