The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Wearable Pressure Sensor Array with Layer-by-Layer Assembled MXene Nanosheets/Ag Nanoflowers for Motion Monitoring and Human–Machine Interfaces
Abstract
Recently, wearable sensors and electronic skin systems have become prevalent, which can be employed to detect the movement status and physiological signals of wearers. Here, a pressure sensor composed of mesh-like micro-convex structure polydimethylsiloxane (PDMS), MXene nanosheet/Ag nanoflower (AgNF) films, and flexible interdigital electrodes was designed by layer-by-layer (LBL) assembly. The unique microstructure of PDMS effectively increases the contact area and improves sensitivity. Moreover, AgNFs were introduced into the MXene as a “bridge,” and the synergistic effect of the two further enhanced the performance of the sensor. The pressure sensor has high sensitivity (191.3 kPa –1 ), good stability (18,000 cycles), fast response/recovery time (80 ms/90 ms), and low detection limit (8 Pa), so it can be used for all-round monitoring of the human body. Sensing arrays were integrated with a wireless transmitter as an intelligent artificial electronic skin for spatial pressure mapping and human–computer interaction sensing. Moreover, we develop a smart glove by a simple method, combining it with a 3D model for wireless accurate detection of hand poses. This provides ideas for hand somatosensory detection technology, leading to health monitoring, intelligent rehabilitation training, and personalized medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metallic Ti3C2T x MXene Gas Sensors with Ultrahigh Signal-to-Noise Ratio
Kim, S. J., Koh, H.-J., Ren, C. E., Kwon, O., Maleski, K., Cho, S.-Y., Anasori, B., Kim, C.-K., Choi, Y.-K., Kim, J., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07460 · Cited by 1,699
Cited by
Recent Advances in Flexible Pressure Sensors Based on MXene Materials
Qin, R., Nong, J., Wang, K., Liu, Y., Zhou, S., Hu, M., Zhao, H., & Shan, G. (2024) · Advanced Materials · doi:10.1002/adma.202312761 · Cited by 416
MXenes for wearable pressure sensing: Progress and prospects in human motion detection
Kong, X., Fan, C., Liao, K., Zhang, W., & Xiong, H. (2025) · Alexandria Engineering Journal · doi:10.1016/j.aej.2025.01.086 · Cited by 7
An Ankle Joint Flexion and Extension Movement-Monitoring Device Based on Pressure Sensors
Xu, C., Zhou, Y., Ji, J., & Wei, C. (2023) · Micromachines · doi:10.3390/mi14122141 · Cited by 5
Metadata
- Authors
- Zhang, H., Zhang, D., Zhang, B., Wang, D., & Tang, M.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2022-10-25
- Volume
- 14
- Issue
- 43
- Pages
- 48907-48916
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W4307201166
- Cited by
- 182
- References
- 1
- FWCI
- 11.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wearable Pressure Sensor Array with Layer-by-Layer Assembled MXene Nanosheets/Ag Nanoflowers for Motion Monitoring and Human–Machine Interfaces. https://app.cochat.ai/papers/10.1021/acsami.2c14863
- The paper
- Zhang, H., Zhang, D., Zhang, B., Wang, D., & Tang, M. (2022). Wearable Pressure Sensor Array with Layer-by-Layer Assembled MXene Nanosheets/Ag Nanoflowers for Motion Monitoring and Human–Machine Interfaces. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.2c14863
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.