An Ankle Joint Flexion and Extension Movement-Monitoring Device Based on Pressure Sensors
Open accessAbstract
Ankle joint flexion and extension movements play an important role in the rehabilitation training of patients who have been injured or bedridden for a long time before and after surgery. Accurately guiding patients to perform ankle flexion and extension movements can significantly reduce deep vein thromboembolism. Currently, most ankle rehabilitation devices focus on assisting patients with ankle flexion and extension movements, and there is a lack of devices for effectively monitoring these movements. In this study, we designed an ankle joint flexion and extension movement-monitoring device based on a pressure sensor. It was composed of an STM32 microcontroller, a pressure sensor, an HX711A/D conversion chip, and an ESP8266 WiFi communication module. The value of the force and the effective number of ankle joint flexion and extension movements were obtained. An experimental device was designed to verify the accuracy of the system. The maximum average error was 0.068 N; the maximum average relative error was 1.7%; the maximum mean-squared error was 0.00464 N. The results indicated that the monitoring device had a high accuracy and could effectively monitor the force of ankle flexion and extension movements, ultimately ensuring that the patient could effectively monitor and grasp the active ankle pump movement.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
For ankle joint flexion and extension movements, wearable monitoring devices developed for this purpose provide new pathways for lower limb motion intention prediction.
“Similarly, for ankle joint flexion and extension movements, wearable monitoring devices developed for this purpose provide new pathways for lower limb motion intention prediction (Fig. 4d) 86 .”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [86]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Large‐Area All‐Textile Pressure Sensors for Monitoring Human Motion and Physiological Signals
Liu, M., Pu, X., Jiang, C., Liu, T., Huang, X. T., Chen, L., Du, C., Sun, J., Hu, W., & Wang, Z. L. (2017) · Advanced Materials · doi:10.1002/adma.201703700 · Cited by 735 · see citing works
Nanomesh pressure sensor for monitoring finger manipulation without sensory interference
Lee, S., Franklin, S., Hassani, F. A., Yokota, T., Nayeem, M. O. G., Wang, Y., Leib, R., Cheng, G., Franklin, D. W., & Someya, T. (2020) · Science · doi:10.1126/science.abc9735 · Cited by 640 · see citing works
Xiong, Y., Shen, Y., Lan, T., Hu, Y., Zhu, P., Sun, R., & Wong, C. (2020) · Nano Energy · doi:10.1016/j.nanoen.2019.104436 · Cited by 550 · see citing works
Wu, Q. H., Qiao, Y., Guo, R., Naveed, S., Hirtz, T., Li, X., Fu, Y., Wei, Y., Deng, G., Yang, Y., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c03294 · Cited by 275 · see citing works
Yang, P., Shi, Y., Li, S., Tao, X., Liu, Z., Wang, X., Wang, Z. L., & Chen, X. (2022) · ACS Nano · doi:10.1021/acsnano.1c11321 · Cited by 196 · see citing works
MQTT based home automation system using ESP8266
Kodali, R. K., & Soratkal, S. (2016) · IEEE Region Humanitarian Technology Conference · doi:10.1109/r10-htc.2016.7906845 · Cited by 188 · see citing works
Zhang, H., Zhang, D., Zhang, B., et al. (2022) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.2c14863 · Cited by 183 · see citing works
Gerlach, C., Krumm, D., Illing, M., et al. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2392084 · Cited by 152 · see citing works
Flexible pressure sensor with a tunable pressure-detecting range for various human motions
Yang, G., Tian, M., Huang, P., Fu, Y., Li, Y., Fu, Y., Wang, X., Li, Y., Hu, N., & Fu, S. (2020) · Carbon · doi:10.1016/j.carbon.2020.11.066 · Cited by 61 · see citing works
Yu, J., Chen, L., Hou, X., et al. (2021) · Journal of Materiomics · doi:10.1016/j.jmat.2021.10.007 · Cited by 61 · see citing works
Venous haemodynamics after total knee arthroplasty
Westrich, G. H., Specht, L. M., Sharrock, N. E., et al. (1998) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.80b6.8627 · Cited by 48 · see citing works
Measurement of Ankle Joint Movements Using IMUs during Running
Kim, B. H., Hong, S. H., Oh, I., Lee, Y. W., Kee, R. I., & Lee, S. Y. (2021) · Sensors · doi:10.3390/s21124240 · Cited by 33 · see citing works
Shimizu, Y., Kamada, H., Sakane, M., et al. (2017) · Journal of orthopaedic surgery · doi:10.1177/2309499017739477 · Cited by 28 · see citing works
Venous haemodynamics after total knee arthroplasty
Westrich, G. H., Specht, L. M., Sharrock, N. E., et al. (1998) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.80b6.0801057 · Cited by 22 · see citing works
Al-Quraishi, M. S., Ishak, A. J., Ahmad, S. A., & Hasan, M. K. (2015) · Asian Control Conference (ASCC) · doi:10.1109/ascc.2015.7244844 · Cited by 14 · see citing works
The influence of ankle joint movement on knee joint kinesthesia at various movement velocities
Brindle, T. J., Lebiedowska, M. K., Miller, J. L., et al. (2009) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/j.1600-0838.2009.00887.x · Cited by 13 · see citing works
Chattopadhyay, S., Banerjee, M., & Pal, S. (2012) · Sensors & transducers · Cited by 5 · see citing works
Exoskeleton for the Ankle Joint Design and Control System
Zhetenbayev, N., Сергазин, Г., Iliev, T. B., et al. (2022) · International Conference on Communications, Information, Electronic and Energy Systems (CIEES) · doi:10.1109/ciees55704.2022.9990064 · Cited by 5 · see citing works
Control of a Device for Mechanotherapy of the Ankle Joint
Knyazev, A. A., Yatsun, A. S., & Fedorov, A. V. (2023) · Biomedical Engineering · doi:10.1007/s10527-023-10243-5 · Cited by 5 · see citing works
Yoon, J., Oh, J., & An, D.-H. (2014) · Foot & Ankle International · doi:10.1177/1071100714543797 · Cited by 4 · see citing works
Design of a High-Precision Force Sensor Signal Acquisition System Based on HX711
Liu, H., & Li, Y. (2021) · doi:10.1145/3513142.3513186 · Cited by 2 · see citing works
Toda, H., & Kawamoto, H. (2023) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2023.p0556 · Cited by 2 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Chen, S., Peng, C., Yang, B., Lin, J., Zhou, L., Jiang, Z., Liu, Z., Liu, Y., & Tang, L. (2026) · npj Artificial Intelligence · doi:10.1038/s44387-026-00083-5 · Cited by 9 · see citing works
- Authors
- Xu, C., Zhou, Y., Ji, J., & Wei, C.
- Affiliations
- Shantou University (CN)
- Zhejiang Provincial Institute of Marine Development and Research, Zhoushan 316100, China
- Corresponding author
- Wei, Chuliang
- Venue
- Micromachines
- Publisher
- MDPI AG
- Published
- 2023-11-22
- Volume
- 14
- Issue
- 12
- Pages
- 2141
- ISSN
- 2072-666X (ISSN-L)
- PMC
- PMC10744840
- OpenAlex
- W4388899131
- Cited by
- 5
- References
- 22
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 1
- FWCI
- 0.39
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Micromachines (publishedVersion, cc-by)
- Preprints.org (acceptedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Zhoushan Science and Technology Plan Project (2022C61002)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Arduino and IoT Applications
- Keywords
- motion monitoring, pressure sensors, ankle rehabilitation, deep vein thrombosis prevention, force measurement, STM32 microcontroller, rehabilitation devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review