Cited by 5Prosthetics and Rehabilitation RoboticsContext-Aware Activity Recognition SystemsArduino and IoT Applications

An Ankle Joint Flexion and Extension Movement-Monitoring Device Based on Pressure Sensors

Open access
Xu, Chunying, Zhou, Yu, Ji, Jian, Wei, Chuliang·2023·Micromachines

Abstract

Ankle joint flexion and extension movements play an important role in the rehabilitation training of patients who have been injured or bedridden for a long time before and after surgery. Accurately guiding patients to perform ankle flexion and extension movements can significantly reduce deep vein thromboembolism. Currently, most ankle rehabilitation devices focus on assisting patients with ankle flexion and extension movements, and there is a lack of devices for effectively monitoring these movements. In this study, we designed an ankle joint flexion and extension movement-monitoring device based on a pressure sensor. It was composed of an STM32 microcontroller, a pressure sensor, an HX711A/D conversion chip, and an ESP8266 WiFi communication module. The value of the force and the effective number of ankle joint flexion and extension movements were obtained. An experimental device was designed to verify the accuracy of the system. The maximum average error was 0.068 N; the maximum average relative error was 1.7%; the maximum mean-squared error was 0.00464 N. The results indicated that the monitoring device had a high accuracy and could effectively monitor the force of ankle flexion and extension movements, ultimately ensuring that the patient could effectively monitor and grasp the active ankle pump movement.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/mi14122141

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Xu, C., Zhou, Y., Ji, J., & Wei, C.
Affiliations
  • Shantou University (CN)
  • Zhejiang Provincial Institute of Marine Development and Research, Zhoushan 316100, China
Corresponding author
Wei, Chuliang
Venue
Micromachines
Publisher
MDPI AG
Published
2023-11-22
Volume
14
Issue
12
Pages
2141
ISSN
2072-666X (ISSN-L)
OpenAlex
W4388899131
Cited by
5
References
22
Citations by year
2026: 2 · 2025: 2 · 2024: 1
FWCI
0.39
Type
journal article
Language
en
Open access
Locations
  • Micromachines (publishedVersion, cc-by)
  • Preprints.org (acceptedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Zhoushan Science and Technology Plan Project (2022C61002)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Arduino and IoT Applications
Keywords
motion monitoring, pressure sensors, ankle rehabilitation, deep vein thrombosis prevention, force measurement, STM32 microcontroller, rehabilitation devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review