The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Dual-Responsive Polymer Coated Superparamagnetic Nanoparticle for Targeted Drug Delivery and Hyperthermia Treatment
Abstract
In this work, we have prepared water-soluble superparamgnetic iron oxide nanoparticles (SPIONs) coated with a dual responsive polymer for targeted delivery of anticancer hydrophobic drug (curcumin) and hyperthermia treatment. Herein, superparamagnetic mixed spinel (MnFe2O4) was used as a core material (15-20 nm) and modified with carboxymethyl cellulose (water-soluble component), folic acid (tagging agent), and dual responsive polymer (poly-N isopropylacrylamide-co-poly glutamic acid) by microwave radiation. Lower critical solution temperature (LCST) of the thermoresponsive copolymer was observed to be around 40 °C, which is appropriate for drug delivery. The polymer-SPIONs show high drug loading capacity (89%) with efficient and fast drug release at the desired pH (5.5) and temperature (40 °C) conditions. Along with this, the SPIONs show a very fast increase in temperature (45 °C in 2 min) when interacting with an external magnetic field, which is an effective and appropriate temperature for the localized hyperthermia treatment of cancer cells. The cytocompatibility of the curcumin loaded SPIONs was studied by the methyl thiazol tetrazolium bromide (MTT) assay, and cells were imaged by fluorescence microscopy. To explore the targeting behavior of curcumin loaded SPIONs, a simple magnetic capturing system (simulating a blood vessel) was constructed and it was found that ∼99% of the nanoparticle accumulated around the magnet in 2 min by traveling a distance of 30 cm. Along with this, to explore an entirely different aspect of the responsive polymer, its antibacterial activity toward an E. coli strain was also studied. It was found that responsive polymer is not harmful for normal or cancer cells but shows a good antibacterial property.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New directions in thermoresponsive polymers
Roy, D., Brooks, W. L. A., & Sumerlin, B. S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35499g · Cited by 1,311
Cited by
The antimicrobial activity of nanoparticles: present situation and prospects for the future
Wang, L., Hu, C., & Shao, L. (2017) · International Journal of Nanomedicine · doi:10.2147/ijn.s121956 · Cited by 4,062
Smart nanocarrier-based drug delivery systems for cancer therapy and toxicity studies: A review
Hossen, S., Hossain, M. K., Basher, M. K., Mia, M. N. H., Rahman, M. T., & Uddin, M. J. (2019) · Journal of Advanced Research · doi:10.1016/j.jare.2018.06.005 · Cited by 998
Ramasamy, T., Ruttala, H. B., Gupta, B., Poudel, B. K., Choi, H.-G., Yong, C. S., & Kim, J. O. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.04.043 · Cited by 373
Use of magnetic fields and nanoparticles to trigger drug release and improve tumor targeting
Liu, J. F., Jang, B., Issadore, D., & Tsourkas, A. (2019) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1571 · Cited by 265
Surface functionalized magnetic nanoparticles for targeted cancer therapy and diagnosis
Saifullah, S., Ali, I., Kawish, M., El-Shabasy, R. M., Chen, L., & El-Seedi, H. R. (2020) · Metal Nanoparticles for Drug Delivery and Diagnostic Applications · doi:10.1016/b978-0-12-816960-5.00012-4 · Cited by 13
Metadata
- Authors
- Patra, S., Roy, E., Karfa, P., Kumar, S., Madhuri, R., & Sharma, P. K.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-04-20
- Volume
- 7
- Issue
- 17
- Pages
- 9235-9246
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2316869454
- Cited by
- 160
- References
- 1
- FWCI
- 10.47
- Type
- journal article
- Language
- en
- Status
- Retracted
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.