Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 358

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

MnO2-Nanosheet-Modified Upconversion Nanosystem for Sensitive Turn-On Fluorescence Detection of H2O2and Glucose in Blood

Yuan, Jing, Cen, Yao, Kong, Xiang-Juan, Wu, Shuang, Liu, Chen-Liwei, Yu, Ru-Qin, Chu, Xia·2015·ACS Applied Materials & Interfaces

Abstract

Blood glucose monitoring has attracted extensive attention because diabetes mellitus is a worldwide public health problem. Here, we reported an upconversion fluorescence detection method based on manganese dioxide (MnO2)-nanosheet-modified upconversion nanoparticles (UCNPs) for rapid, sensitive detection of glucose levels in human serum and whole blood. In this strategy, MnO2 nanosheets on the UCNP surface serve as a quencher. UCNP fluorescence can make a recovery by the addition of H2O2, which can reduce MnO2 to Mn(2+), and the glucose can thus be monitored based on the enzymatic conversion of glucose by glucose oxidase to generate H2O2. Because of the nonautofluorescent assays offered by UCNPs, the developed method has been applied to monitor glucose levels in human serum and whole blood samples with satisfactory results. The proposed approach holds great potential for diabetes mellitus research and clinical diagnosis. Meanwhile, this nanosystem is also generalizable and can be easily expanded to the detection of various H2O2-involved analytes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.5b02188

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 358

Metadata

Authors
Yuan, J., Cen, Y., Kong, X.-J., Wu, S., Liu, C.-L., Yu, R.-Q., & Chu, X.
Venue
ACS Applied Materials & Interfaces
Published
2015-05-07
Volume
7
Issue
19
Pages
10548-10555
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2329427351
Cited by
358
References
1
FWCI
15.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.