The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Honeycomb-like Porous Carbon–Cobalt Oxide Nanocomposite for High-Performance Enzymeless Glucose Sensor and Supercapacitor Applications
Abstract
Herein, we report the preparation of Pongam seed shells-derived activated carbon and cobalt oxide (∼2-10 nm) nanocomposite (PSAC/Co3O4) by using a general and facile synthesis strategy. The as-synthesized PSAC/Co3O4 samples were characterized by a variety of physicochemical techniques. The PSAC/Co3O4-modified electrode is employed in two different applications such as high performance nonenzymatic glucose sensor and supercapacitor. Remarkably, the fabricated glucose sensor is exhibited an ultrahigh sensitivity of 34.2 mA mM(-1) cm(-2) with a very low detection limit (21 nM) and long-term durability. The PSAC/Co3O4 modified stainless steel electrode possesses an appreciable specific capacitance and remarkable long-term cycling stability. The obtained results suggest the as-synthesized PSAC/Co3O4 is more suitable for the nonenzymatic glucose sensor and supercapacitor applications outperforming the related carbon based modified electrodes, rendering practical industrial applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
KOH activation of carbon-based materials for energy storage
Wang, J., & Kaskel, S. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm34066f · Cited by 2,726
Energy storage applications of activated carbons: supercapacitors and hydrogen storage
Sevilla, M., & Mokaya, R. (2014) · Energy Environ. Sci. · doi:10.1039/c3ee43525c · Cited by 1,614
Dong, X.-C., Xu, H., Wang, X.-W., Huang, Y.-X., Chan-Park, M. B., Zhang, H., Wang, L.-H., Huang, W., & Chen, P. (2012) · ACS Nano · doi:10.1021/nn300097q · Cited by 1,595
Glucose oxidase: an ideal enzyme
Wilson, R., & Turner, A. P. F. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)87013-f · Cited by 1,350
Synthesis of functionalized 3D hierarchical porous carbon for high-performance supercapacitors
Qie, L., Chen, W., Xu, H., Xiong, X., Jiang, Y., Zou, F., Hu, X., Xin, Y., Zhang, Z., & Huang, Y. (2013) · Energy & Environmental Science · doi:10.1039/c3ee41638k · Cited by 1,147
Rakhi, R. B., Chen, W., Cha, D., & Alshareef, H. N. (2012) · Nano Letters · doi:10.1021/nl300779a · Cited by 816
Sevilla, M., & Fuertes, A. B. (2014) · ACS Nano · doi:10.1021/nn501124h · Cited by 738
Electrospun Co3O4 nanofibers for sensitive and selective glucose detection
Ding, Y., Wang, Y., Su, L., Bellagamba, M., Zhang, H., & Lei, Y. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.07.050 · Cited by 707
Kang, X., Mai, Z., Zou, X., Cai, P., & Mo, J. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2007.01.003 · Cited by 572
Guan, Q., Cheng, J., Wang, B., Ni, W., Gu, G., Li, X., Huang, L., Yang, G., & Nie, F. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am5009369 · Cited by 333
The ternary MnFe2O4/graphene/polyaniline hybrid composite as negative electrode for supercapacitors
Sankar, K. V., & Selvan, R. K. (2014) · Journal of Power Sources · doi:10.1016/j.jpowsour.2014.10.183 · Cited by 243
Madhu, R., Sankar, K. V., Chen, S.-M., & Selvan, R. K. (2014) · RSC Adv. · doi:10.1039/c3ra45089a · Cited by 197
Self-citationCobalt oxide acicular nanorods with high sensitivity for the non-enzymatic detection of glucose
Kung, C.-W., Lin, C.-Y., Lai, Y.-H., Vittal, R., & Ho, K.-C. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.06.033 · Cited by 188
Bharath, G., Madhu, R., Chen, S.-M., Veeramani, V., Balamurugan, A., Mangalaraj, D., Viswanathan, C., & Ponpandian, N. (2015) · Journal of Materials Chemistry B · doi:10.1039/c4tb01651c · Cited by 166
Self-citationA graphene–cobalt oxide based needle electrode for non-enzymatic glucose detection in micro-droplets
Wang, X., Dong, X., Wen, Y., Li, C., Xiong, Q., & Chen, P. (2012) · Chemical Communications · doi:10.1039/c2cc32674d · Cited by 160
Wang, H.-W., Hu, Z.-A., Chang, Y.-Q., Chen, Y.-L., Zhang, Z.-Y., Yang, Y.-Y., & Wu, H.-Y. (2011) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2011.07.043 · Cited by 159
Patil, U. M., Lee, S. C., KULKARNI, D. S. B., Sohn, J. S., Nam, M. S., Han, S.-H., & Jun, S. C. (2015) · Nanoscale · doi:10.1039/c5nr01135c · Cited by 139
Co3O4 microspheres with free-standing nanofibers for high performance non-enzymatic glucose sensor
Guo, C., Zhang, X., Huo, H., Xu, C., & Han, X. (2013) · The Analyst · doi:10.1039/c3an01403g · Cited by 129
Madhu, R., Veeramani, V., & Chen, S. (2014) · Scientific Reports · doi:10.1038/srep04679 · Cited by 115
Self-citationWu, M.-S., Lin, Y., Lin, C., & Lee, J. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm13818a · Cited by 114
Dai, M., Song, L., Belle, J. T. L., & Vogt, B. D. (2011) · Chemistry of Materials · doi:10.1021/cm2002429 · Cited by 100
Li, G., Huo, H., & Xu, C. (2015) · Journal of Materials Chemistry A · doi:10.1039/c4ta06553k · Cited by 62
A non-enzymatic amperometric sensor for glucose based on cobalt oxide nanoparticles
Sattarahmady, N., & Heli, H. (2012) · Journal of Experimental Nanoscience · doi:10.1080/17458080.2010.539275 · Cited by 58
Zhang, L., He, W., Xiang, X., Li, Y., & Li, F. (2014) · RSC Advances · doi:10.1039/c4ra07082h · Cited by 49
Pumpkin stem-derived activated carbons as counter electrodes for dye-sensitized solar cells
Madhu, R., Veeramani, V., Chen, S., Jayabal, P., & Vilian, A. T. E. (2014) · RSC Advances · doi:10.1039/c4ra12585a · Cited by 47
Self-citation
Cited by
Recent advances in electrochemical non-enzymatic glucose sensors – A review
Hwang, D.-W., Lee, S., Seo, M., & Chung, T. D. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.05.051 · Cited by 788
Advances in non-enzymatic glucose sensors based on metal oxides
Zhu, H., Li, L., Zhou, W., Shao, Z., & Chen, X. (2016) · Journal of Materials Chemistry B · doi:10.1039/c6tb02037b · Cited by 473
Gao, S., Li, X., Li, L., & Wei, X. (2017) · Nano Energy · doi:10.1016/j.nanoen.2017.01.045 · Cited by 400
Metal oxide based non-enzymatic electrochemical sensors for glucose detection
Dong, Q., Ryu, H., & Lei, Y. (2021) · Electrochimica Acta · doi:10.1016/j.electacta.2021.137744 · Cited by 338
Biomass‐Derived Carbon Materials: Controllable Preparation and Versatile Applications
Wang, Y., Zhang, M., Shen, X., Wang, H., Wang, H., Xia, K., Yin, Z., & Zhang, Y. (2021) · Small · doi:10.1002/smll.202008079 · Cited by 324
Metadata
- Authors
- Madhu, R., Veeramani, V., Chen, S.-M., Manikandan, A., Lo, A.-Y., & Chueh, Y.-L.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-07-21
- Volume
- 7
- Issue
- 29
- Pages
- 15812-15820
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2473563782
- Cited by
- 253
- References
- 25
- FWCI
- 13.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.