Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 162

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Fluoroalkylsilane-Modified Textile-Based Personal Energy Management Device for Multifunctional Wearable Applications

Guo, Yinben, Li, Kerui, Hou, Chengyi, Li, Yaogang, Zhang, Qinghong, Wang, Hongzhi·2016·ACS Applied Materials & Interfaces

Abstract

The rapid development of wearable electronics in recent years has brought increasing energy consumption, making it an urgent need to focus on personal energy harvesting, storage and management. Herein, a textile-based personal energy management device with multilayer-coating structure was fabricated by encapsulating commercial nylon cloth coated with silver nanowires into polydimethylsiloxane using continuous and facile dip-coating method. This multilayer-coating structure can not only harvest mechanical energy from human body motion to power wearable electronics but also save energy by keeping people warm without losing heat to surroundings and wasting energy to heat empty space and inanimate objects. Fluoroalkylsilanes (FAS) were grafted onto the surface of the film through one single dip-coating process to improve its energy harvesting performance, which has hardly adverse effect to heat insulation and Joule heating property. In the presence of FAS modification, the prepared film harvested mechanical energy to reach a maximum output power density of 2.8 W/m(2), charged commercial capacitors and lighted LEDs, showing its potential in powering wearable electronics. Furthermore, the film provided 8% more thermal insulation than normal cloth at 37 °C and efficiently heated to 40 °C within 4 min when applied the voltage of only 1.5 V due to Joule heating effect. The high flexibility and stability of the film ensures its wide and promising application in the wearable field.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.5b11622

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 162

Metadata

Authors
Guo, Y., Li, K., Hou, C., Li, Y., Zhang, Q., & Wang, H.
Venue
ACS Applied Materials & Interfaces
Published
2016-02-09
Volume
8
Issue
7
Pages
4676-4683
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2327146789
Cited by
162
References
4
FWCI
6.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fluoroalkylsilane-Modified Textile-Based Personal Energy Management Device for Multifunctional Wearable Applications. https://app.cochat.ai/papers/10.1021/acsami.5b11622
The paper
Guo, Y., Li, K., Hou, C., Li, Y., Zhang, Q., & Wang, H. (2016). Fluoroalkylsilane-Modified Textile-Based Personal Energy Management Device for Multifunctional Wearable Applications. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.5b11622

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.