The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
MOF-Based Membrane Encapsulated ZnO Nanowires for Enhanced Gas Sensor Selectivity
Open accessAbstract
Gas sensors are of a great interest for applications including toxic or explosive gases detection in both in-house and industrial environments, air quality monitoring, medical diagnostics, or control of food/cosmetic properties. In the area of semiconductor metal oxides (SMOs)-based sensors, a lot of effort has been devoted to improve the sensing characteristics. In this work, we report on a general methodology for improving the selectivity of SMOx nanowires sensors, based on the coverage of ZnO nanowires with a thin ZIF-8 molecular sieve membrane. The optimized ZnO@ZIF-8-based nanocomposite sensor shows markedly selective response to H2 in comparison with the pristine ZnO nanowires sensor, while showing the negligible sensing response to C7H8 and C6H6. This original MOF-membrane encapsulation strategy applied to nanowires sensor architecture pave the way for other complex 3D architectures and various types of applications requiring either gas or ion selectivity, such as biosensors, photo(catalysts), and electrodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metal–Organic Framework Materials as Chemical Sensors
Kreno, L. E., Leong, K., Farha, O. K., Allendorf, M., Van Duyne, R. P., & Hupp, J. T. (2012) · Chemical Reviews · doi:10.1021/cr200324t · Cited by 7,136
Metal oxides for solid-state gas sensors: What determines our choice?
Korotcenkov, G. (2007) · Materials Science and Engineering: B · doi:10.1016/j.mseb.2007.01.044 · Cited by 1,670
Nanostructured Materials for Room‐Temperature Gas Sensors
Zhang, J., Liu, X., Neri, G., & Pinna, N. (2016) · Advanced Materials · doi:10.1002/adma.201503825 · Cited by 1,569
A Survey on Gas Sensing Technology
Liu, X., Cheng, S., Liu, H., Hu, S., Zhang, D., & Ning, H. (2012) · Sensors · doi:10.3390/s120709635 · Cited by 1,416
Lu, G., & Hupp, J. T. (2010) · Journal of the American Chemical Society · doi:10.1021/ja101415b · Cited by 1,082
A Survey on Gas Sensing Technology
Liu, X., Cheng, S., Liu, H., Hu, S., Zhang, D., & Ning, H. (2012) · Cited by 926
Zhan, W.-W., Kuang, Q., Zhou, J.-Z., Kong, X.-J., Xie, Z.-X., & Zheng, L.-S. (2013) · Journal of the American Chemical Society · doi:10.1021/ja311085e · Cited by 803
Atomic Layer Deposition of Nanostructured Materials for Energy and Environmental Applications
Marichy, C., Bechelany, M., & Pinna, N. (2012) · Advanced Materials · doi:10.1002/adma.201104129 · Cited by 591
Self-citationMetal–Organic Frameworks as Sensory Materials and Imaging Agents
Liu, D., Lu, K., Poon, C., & Lin, W. (2014) · Inorganic Chemistry · doi:10.1021/ic402194c · Cited by 386
Solid-state gas sensors for breath analysis: A review
Di Natale, C., Paolesse, R., Martinelli, E., & Capuano, R. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.03.014 · Cited by 365
Advances and new directions in gas-sensing devices
Kim, I.-D., Rothschild, A., & Tuller, H. L. (2013) · Acta Materialia · doi:10.1016/j.actamat.2012.10.041 · Cited by 343
Multifunctional Nanoparticle@MOF Core–Shell Nanostructures
Liu, Y., & Tang, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302781 · Cited by 323
Metal−organic framework encapsulated Pd nanoparticles: towards advanced heterogeneous catalysts
Chen, L., Chen, H., Luque, R., & Li, Y. (2014) · Chem. Sci. · doi:10.1039/c4sc01847h · Cited by 259
Engineering approaches for the improvement of conductometric gas sensor parameters
Korotcenkov, G., & Cho, B. K. (2013) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.07.101 · Cited by 243
Environmental Monitoring Systems: A Review
Kumar, A., Kim, H., & Hancke, G. P. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2012.2233469 · Cited by 197
Well‐Defined Metal–Organic‐Framework Hollow Nanostructures for Catalytic Reactions Involving Gases
Xu, X., Zhang, Z., & Wang, X. (2015) · Advanced Materials · doi:10.1002/adma.201500789 · Cited by 179
Katoch, A., Kim, J.-H., Kwon, Y. J., Kim, H. W., & Kim, S. S. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b01817 · Cited by 175
Self-citationDrobek, M., Bechelany, M., Vallicari, C., Chaaya, A. A., Charmette, C., Salvador-Levehang, C., Miele, P., & Julbe, A. (2014) · Journal of Membrane Science · doi:10.1016/j.memsci.2014.10.011 · Cited by 121
Self-citationKorotcenkov, G. S., & Cho, B. K. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.03.069 · Cited by 117
Ponzoni, A., Comini, E., Concina, I., Ferroni, M., Falasconi, M., Gobbi, E., Sberveglieri, V., & Sberveglieri, G. (2012) · Sensors · doi:10.3390/s121217023 · Cited by 84
Cited by
Stassen, I., Burtch, N., Talin, A., Falcaro, P., Allendorf, M., & Ameloot, R. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00122c · Cited by 1,210
Yang, S., Jiang, C., & Wei, S.-H. (2017) · Applied Physics Reviews · doi:10.1063/1.4983310 · Cited by 876
Metal-Organic Frameworks for Chemiresistive Sensors
Koo, W.-T., Jang, J.-S., & Kim, I.-D. (2019) · Chem · doi:10.1016/j.chempr.2019.04.013 · Cited by 680
Metal-oxide-semiconductor based gas sensors: screening, preparation, and integration
Zhang, J., Qin, Z., Zeng, D., & Xie, C. (2017) · Physical Chemistry Chemical Physics · doi:10.1039/c6cp07799d · Cited by 556
Gas Sensors Based on Chemi-Resistive Hybrid Functional Nanomaterials
Jian, Y., Hu, W., Zhao, Z., Cheng, P., Haick, H., Yao, M., & Wu, W. (2020) · Nano-Micro Letters · doi:10.1007/s40820-020-0407-5 · Cited by 429
Metadata
- Authors
- Drobek, M., Kim, J.-H., Bechelany, M., Vallicari, C., Julbe, A., & Kim, S. S.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-03-25
- Volume
- 8
- Issue
- 13
- Pages
- 8323-8328
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2305337401
- Cited by
- 430
- References
- 20
- FWCI
- 21.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.