The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Co3O4–SnO2 Hollow Heteronanostructures: Facile Control of Gas Selectivity by Compositional Tuning of Sensing Materials via Galvanic Replacement
Abstract
Co3O4 hollow spheres prepared by ultrasonic spray pyrolysis were converted into Co3O4-SnO2 core-shell hollow spheres by galvanic replacement with subsequent calcination at 450 °C for 2 h for gas sensor applications. Gas selectivity of the obtained spheres can be controlled by varying the amount of SnO2 shells (14.6, 24.3, and 43.3 at. %) and sensor temperatures. Co3O4 sensors possess an ability to selectively detect ethanol at 275 °C. When the amount of SnO2 shells was increased to 14.6 and 24.3 at. %, highly selective detection of xylene and methylbenzenes (xylene + toluene) was achieved at 275 and 300 °C, respectively. Good selectivity of Co3O4 hollow spheres to ethanol can be explained by a catalytic activity of Co3O4; whereas high selectivity of Co3O4-SnO2 core-shell hollow spheres to methylbenzenes is attributed to a synergistic effect of catalytic SnO2 and Co3O4 and promotion of gas sensing reactions by a pore-size control of microreactors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shannon, R. D. (1976) · Acta Crystallographica Section A · doi:10.1107/s0567739476001551 · Cited by 66,145
Magnetic iron oxide nanoparticles: synthesis and surface functionalization strategies
Wu, W., He, Q., & Jiang, C. (2008) · Nanoscale Research Letters · doi:10.1007/s11671-008-9174-9 · Cited by 2,300
Cited by
Synergistic effects in gas sensing semiconducting oxide nano-heterostructures: A review
Walker, J. M., Akbar, S. A., & Morris, P. A. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2019.01.049 · Cited by 602
Jeong, S., Kim, J., & Lee, J. (2020) · Advanced Materials · doi:10.1002/adma.202002075 · Cited by 415
Self-citationKoo, W.-T., Yu, S., Choi, S.-J., Jang, J.-S., Cheong, J. Y., & Kim, I.-D. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b01284 · Cited by 297
Synergy between nanomaterials and volatile organic compounds for non-invasive medical evaluation
Broza, Y. Y., Vishinkin, R., Barash, O., Nakhleh, M. K., & Haick, H. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00317c · Cited by 276
Superior acetone gas sensor based on electrospun SnO2 nanofibers by Rh doping
Kou, X., Xie, N., Chen, F., Wang, T., Guo, L., Wang, C., Wang, Q., Ma, J., Sun, Y., Zhang, H., et al. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.10.011 · Cited by 265
Wang, J., Fan, S., Xia, Y., Yang, C., & Komarneni, S. (2020) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2019.120919 · Cited by 264
Jiao, W., He, J., & Zhang, L. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.127786 · Cited by 66
Physisorption induced p-xylene gas-sensing performance of (C4H9NH3)2PbI4 layered perovskite
Zhu, M.-Y., Zhang, L.-X., Yin, J., Chen, J.-J., Bie, L.-J., & Fahlman, B. D. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.11.124 · Cited by 45
Metadata
- Authors
- Jeong, H.-M., Kim, J.-H., Jeong, S.-Y., Kwak, C.-H., & Lee, J.-H.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-03-18
- Volume
- 8
- Issue
- 12
- Pages
- 7877-7883
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2294442575
- Cited by
- 161
- References
- 2
- FWCI
- 13.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.