The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Highly Sensitive Textile Strain Sensors and Wireless User-Interface Devices Using All-Polymeric Conducting Fibers
Abstract
Emulation of diverse electronic devices on textile platform is considered as a promising approach for implementing wearable smart electronics. Of particular, the development of multifunctional polymeric fibers and their integration in common fabrics have been extensively researched for human friendly wearable platforms. Here we report a successful emulation of multifunctional body-motion sensors and user-interface (UI) devices in textile platform by using in situ polymerized poly(3,4-ethylenedioxythiophene) (PEDOT)-coated fibers. With the integration of PEDOT fibers in a fabric, via an optimization of the fiber pattern design, multifunctional textile sensors such as highly sensitive and reliable strain sensors (with maximum gauge factor of ∼1), body-motion monitoring sensors, touch sensors, and multilevel strain recognition UI devices were successfully emulated. We demonstrate the facile utilization of the textile-based multifunctional sensors and UI devices by implementing in a wireless system that is capable of expressing American Sign Language through predefined hand gestures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Highly Stretchable and Sensitive Strain Sensor Based on Silver Nanowire–Elastomer Nanocomposite
Amjadi, M., Pichitpajongkit, A., Lee, S., Ryu, S., & Park, I. (2014) · ACS Nano · doi:10.1021/nn501204t · Cited by 2,350
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Bandodkar, A. J., Jeerapan, I., You, J.-M., Nuñez-Flores, R., & Wang, J. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b04549 · Cited by 341
A Textile‐Based Stretchable Multi‐Ion Potentiometric Sensor
Parrilla, M., Cánovas, R., Jeerapan, I., Andrade, F. J., & Wang, J. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600092 · Cited by 269
Cited by
Smart Textile‐Integrated Microelectronic Systems for Wearable Applications
Shi, J., Liu, S., Zhang, L., Yang, B., Shu, L., Yang, Y., Ren, M., Wang, Y., Chen, J., Chen, W., et al. (2020) · Advanced Materials · doi:10.1002/adma.201901958 · Cited by 822
Heo, J. S., Eom, J., Kim, Y., & Park, S. K. (2018) · Small · doi:10.1002/smll.201703034 · Cited by 631
Self-citationFunctional Fibers and Fabrics for Soft Robotics, Wearables, and Human–Robot Interface
Xiong, J., Chen, J., & Lee, P. S. (2021) · Advanced Materials · doi:10.1002/adma.202002640 · Cited by 627
Mechanically Flexible Conductors for Stretchable and Wearable E‐Skin and E‐Textile Devices
Wang, B., & Facchetti, A. (2019) · Advanced Materials · doi:10.1002/adma.201901408 · Cited by 515
Flexible Hybrid Sensors for Health Monitoring: Materials and Mechanisms to Render Wearability
Gao, Y., Yu, L., Yeo, J. C., & Lim, C. T. (2020) · Advanced Materials · doi:10.1002/adma.201902133 · Cited by 505
Metadata
- Authors
- Eom, J., Jaisutti, R., Lee, H., Lee, W., Heo, J.-S., Lee, J.-Y., Park, S. K., & Kim, Y.-H.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-03-09
- Volume
- 9
- Issue
- 11
- Pages
- 10190-10197
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2594672651
- Cited by
- 208
- References
- 5
- FWCI
- 7.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.