The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Microwave-Assisted Synthesis of Graphene–SnO2 Nanocomposites and Their Applications in Gas Sensors
Abstract
We obtained extremely high and selective sensitivity to NO 2 gas by fabricating graphene–SnO 2 nanocomposites using a commercial microwave oven. Structural characterization revealed that the products corresponded to agglomerated structures of graphene and SnO 2 particles, with small secondary SnO x ( x ≤ 2) nanoparticles deposited on the surfaces. The overall oxygen atomic ratio was decreased with the appearance of an SnO x ( x < 2) phase. By the microwave treatment of graphene–SnO 2 nanocomposites, with the graphene promoting efficient transport of the microwave energy, evaporation and redeposition of SnO x nanoparticles were facilitated. The graphene–SnO 2 nanocomposites exhibited a high sensor response of 24.7 for 1 ppm of NO 2 gas, at an optimized temperature of 150 °C. The graphene–SnO 2 nanocomposites were selectively sensitive to NO 2 gas, in comparison with SO 2, NH 3, and ethanol gases. We suggest that the generation of SnO x nanoparticles and the SnO x phase in the matrix results in the formation of SnO 2 /SnO 2 homojunctions, SnO 2 /SnO x ( x < 2) heterojunctions, and SnO 2 /graphene heterojunctions, which are responsible for the excellent sensitivity of the graphene–SnO 2 nanocomposites to NO 2 gas. In addition, the generation of surface Sn interstitial defects is also partly responsible for the excellent NO 2 sensing performance observed in this study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Graphene nanoelectronic heterodyne sensor for rapid and sensitive vapour detection
Kulkarni, G. S., Reddy, K., Zhong, Z., & Fan, X. (2014) · Nature Communications · doi:10.1038/ncomms5376 · Cited by 189
Cited by
Li, Z., Li, H., Wu, Z., Wang, M., Luo, J., Torun, H., Hu, P., Yang, C., Grundmann, M., Liu, X., et al. (2019) · Materials Horizons · doi:10.1039/c8mh01365a · Cited by 760
Recent Advances in Electrochemical Sensors for Detecting Toxic Gases: NO2, SO2 and H2S
Khan, M. A. H., Rao, M. V., & Li, Q. (2019) · Sensors · doi:10.3390/s19040905 · Cited by 417
Nanostructured metal oxides and its hybrids for photocatalytic and biomedical applications
Kannan, K., Radhika, D., Sadasivuni, K. K., Reddy, K. R., & Raghu, A. V. (2020) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2020.102178 · Cited by 341
Metal-Oxide Nanomaterials Synthesis and Applications in Flexible and Wearable Sensors
Yoon, Y., Truong, P. L., Lee, D., & Ko, S. H. (2022) · ACS Nanoscience Au · doi:10.1021/acsnanoscienceau.1c00029 · Cited by 313
Design of Hetero-Nanostructures on MoS2 Nanosheets To Boost NO2 Room-Temperature Sensing
Han, Y., Huang, D., Ma, Y., He, G., Hu, J., Zhang, J., Hu, N., Su, Y., Zhou, Z., Zhang, Y., et al. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b05811 · Cited by 279
Metadata
- Authors
- Kim, H. W., Na, H. G., Kwon, Y. J., Kang, S. Y., Choi, M. S., Bang, J. H., Wu, P., & Kim, S. S.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-09-11
- Volume
- 9
- Issue
- 37
- Pages
- 31667-31682
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2748866382
- Cited by
- 178
- References
- 1
- FWCI
- 7.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microwave-Assisted Synthesis of Graphene–SnO2 Nanocomposites and Their Applications in Gas Sensors. https://app.cochat.ai/papers/10.1021/acsami.7b02533
- The paper
- Kim, H. W., Na, H. G., Kwon, Y. J., Kang, S. Y., Choi, M. S., Bang, J. H., Wu, P., & Kim, S. S. (2017). Microwave-Assisted Synthesis of Graphene–SnO2 Nanocomposites and Their Applications in Gas Sensors. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.7b02533
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.