The DOI matches its Crossref record.
Dual-Colored Carbon Dot Ratiometric Fluorescent Test Paper Based on a Specific Spectral Energy Transfer for Semiquantitative Assay of Copper Ions
Abstract
Classical pH test papers are widely used to measure the acid–base degree of media in a qualitative or semiquantitative manner. However, the extension of portable and inexpensive methods to a wide range of analytes so as to eliminate the tediousness of instrumental assays remains unsuccessful. Here, we report a novel kind of dual-colored carbon dot (CD) ratiometric fluorescent test paper for the semiquantitative assay of copper ions (Cu 2+ ) by a dose-sensitive color evolution. The preparation of the test paper is based on the following two interesting findings: on the one hand, residual p -phenylenediamine at the surface of as-synthesized red CDs (r-CDs) efficiently binds Cu 2+ ions to produce a strong visible absorption that overlaps the emission of blue CDs (b-CDs); on the other hand, the Cu 2+ ions render the adsorption of small b-CDs onto the surface of larger r-CDs through their dual-coordinating interactions with the surface ligands of both r-CDs and b-CDs. These two mechanisms lead to a specific spectral energy transfer to quench the fluorescence of b-CDs with a sensitive detection limit of 8.82 nM Cu 2+, whereas the red fluorescence of r-CDs is unaffected as a stable internal standard. Ratiometric fluorescent test papers have been prepared using a mixture of r-CDs and b-CDs (1:7) as ink by jetprinting on a piece of paper. With the addition of Cu 2+ ions, the blue test paper produces a consecutive wide-colored evolution from blue to orange-red, with a dose-discerning ability as low as 25 nM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Applications of carbon dots in environmental pollution control: A review
Long, C., Jiang, Z., Shangguan, J., Qing, T., Zhang, P., & Feng, B. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.126848 · Cited by 434
Wang, H., Yang, L., Chu, S., Liu, B., Zhang, Q., Zou, L., Yu, S., & Jiang, C. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02297 · Cited by 400
Self-citationCarbon dots with red/near-infrared emissions and their intrinsic merits for biomedical applications
Ding, H., Zhou, X.-X., Wei, J.-S., Li, X.-B., Qin, B.-T., Chen, X.-B., & Xiong, H.-M. (2020) · Carbon · doi:10.1016/j.carbon.2020.06.024 · Cited by 256
Duarah, R., Torné‐Morató, H., Zhang, G., Amin, Y., Pabast, M., Sharma, N., He, S., Das, M. R., & Pompa, P. P. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.202504419 · Cited by 24
Metadata
- Authors
- Liu, C., Ning, D., Zhang, C., Liu, Z., Zhang, R., Zhao, J., Zhao, T., Liu, B., & Zhang, Z.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-05-26
- Volume
- 9
- Issue
- 22
- Pages
- 18897-18903
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2615898263
- Cited by
- 164
- References
- 0
- FWCI
- 8.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.