The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Simultaneous High Sensitivity Sensing of Temperature and Humidity with Graphene Woven Fabrics
Abstract
Temperature and moisture are critical factors for both the environment and living creatures. Most temperature sensors and humidity sensors are rigid. It still remains an unsolved problem to fabricate a flexible sensor that can easily detect temperature and humidity at the same time. In this work, we made a flexible multifunctional temperature and humidity sensor from graphene woven fabrics. The integrated sensor could measure temperature and humidity simultaneously. The temperature-sensing part and the humidity-sensing part were stacked in layer structure, occupying little space and showing good flexibility while exhibiting high sensitivity and very little mutual interference. The different factors that affected the sensing properties of the sensor were examined. The integrated sensor was successfully utilized in several real life application scenarios, which showed its potential for wider use in environment sensing and health monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Porous Ionic Membrane Based Flexible Humidity Sensor and its Multifunctional Applications
Li, T., Li, L., Sun, H., Xu, Y., Wang, X., Luo, H., Liu, Z., & Zhang, T. (2017) · Advanced Science · doi:10.1002/advs.201600404 · Cited by 298
Cited by
Liu, L., Chen, W., Zhang, H., Wang, Q., Guan, F., & Yu, Z. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201905197 · Cited by 699
Electronic Textiles for Wearable Point-of-Care Systems
Chen, G., Xiao, X., Zhao, X., Tat, T., Bick, M., & Chen, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00502 · Cited by 688
Self-citationMechanically Flexible Conductors for Stretchable and Wearable E‐Skin and E‐Textile Devices
Wang, B., & Facchetti, A. (2019) · Advanced Materials · doi:10.1002/adma.201901408 · Cited by 515
Graphene-based wearable piezoresistive physical sensors
Zheng, Q., Lee, J.-H., Shen, X., Chen, X., & Kim, J.-K. (2020) · Materials Today · doi:10.1016/j.mattod.2019.12.004 · Cited by 486
Duan, Z., Jiang, Y., Yan, M., Wang, S., Yuan, Z., Zhao, Q., Sun, P., Xie, G., Du, X., & Tai, H. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b05709 · Cited by 485
Metadata
- Authors
- Zhao, X., Long, Y., Yang, T., Li, J., & Zhu, H.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-08-28
- Volume
- 9
- Issue
- 35
- Pages
- 30171-30176
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2749960601
- Cited by
- 158
- References
- 1
- FWCI
- 5.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.