Porous Ionic Membrane Based Flexible Humidity Sensor and its Multifunctional Applications

Open access
Li, Tie, Li, Lianhui, Sun, Hongwei, Xu, Yan, Wang, Xuewen, Luo, Hui, Liu, Zheng, Zhang, Ting·2017·Advanced Science

Abstract

A highly flexible porous ionic membrane (PIM) is fabricated from a polyvinyl alcohol/KOH polymer gel electrolyte, showing well‐defined 3D porous structure. The conductance of the PIM changes more than 70 times as the relative humidity (RH) increases from 10.89% to 81.75% with fast and reversible response at room temperature. In addition, the PIM‐based sensor is insensitive to temperature (0–95 °C) and pressure (0–6.8 kPa) change, which indicates that it can be used as highly selective flexible humidity sensor. A noncontact switch system containing PIM‐based sensor is assembled, and results show that the switch responds favorably to RH change caused by an approaching finger. Moreover, an attachable smart label using PIM‐based sensor is explored to measure the water contents of human skin, which shows a great linear relationship between the sensitivity of the sensor and the facial water contents measured by a commercial reference device.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/advs.201600404

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Encapsulation of hydrogel sensors with elastomeric materials is an effective approach to prevent the evaporation of water from hydrogels.

    “The encapsulation of hydrogel sensors with elastomeric materials is an effective approach to prevent the evaporation of water from hydrogels”

    From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as [154]

    The Results and Discussion section describes a nonporous PDMS outer layer that prevents interference from ambient humidity, not evaporation of water from a hydrogel. The paper also describes drying a PVA/KOH gel to make a porous membrane. Searches for elastomer encapsulation and prevention of hydrogel water evaporation found no passage addressing the claim; page numbers were not supplied. (LLM, conf=0.74)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 40

  1. [1]A. Chortos, G. I. Koleilat, R. Pfattner, D. S. Kong, P. Lin, R. Nur, T. Lei, H. L. Wang, N. Liu, Y. C. Lai, M. G. Kim, J. W. Chung, S. Lee, Z. N. Bao, Adv. Mater. 2016, 28, 4441. 26179120
  2. [2]M. L. Hammock, A. Chortos, B. C. K. Tee, J. B. H. Tok, Z. N. Bao, Adv. Mater. 2013, 25, 5997. 24151185
  3. [3]Y. Khan, A. E. Ostfeld, C. M. Lochner, A. Pierre, A. C. Arias, Adv. Mater. 2016, 28, 4373. 26867696
  4. [5]S. Choi, H. Lee, R. Ghaffari, T. Hyeon, D. H. Kim, Adv. Mater. 2016, 28, 4203. 26779680
  5. [6]Y. P. Zang, D. Z. Huang, C. A. D, D. B. Zhu, Adv. Mater. 2016, 28, 4549. 26833747
  6. [7]W. R. K. Illeperuma, P. Rothemund, Z. G. Suo, J. J. Vlassak, ACS Appl. Mater. Interfaces 2016, 8, 2071. 26716351
  7. [8]J. Y. Sun, C. Keplinger, G. M. Whitesides, Z. G. Suo, Adv. Mater. 2014, 26, 7608. 25355528
  8. [9]Y. H. Tai, G. Lubineau, Sci. Rep. 2016, 6, 19632. 26818091 PMC4730204
  9. [10]Y. H. Tai, M. Mulle, I. A. Ventura, G. Lubineau, Nanoscale 2015, 7, 14766. 26288336
  10. [11]Z. L. Yang, Z. Y. Zhang, K. C. Liu, Q. Yuan, B. Dong, J. Mater. Chem. C 2015, 3, 6701.
  11. [12]D. W. Jung, J. H. Kim, G. S. Lee, Sens. Actuators, A 2015, 223, 11.
  12. [13]M. Y. Lim, H. Shin, D. M. Shin, S. S. Lee, J. C. Lee, Polymer 2016, 84, 89.
  13. [14]Z. C. Zhu, T. Horiuchi, K. Kruusamäe, L. F. Chang, K. Asaka, J. Phys. Chem. B 2016, 120, 3215. 26977537
  14. [15]P. G. Su, Z. M. Lu, Sens. Actuators, B 2015, 211, 157.
  15. [16]R. Virginia, F. Iván, C. Pedro, C. Germán, J. G. Hans, H. Jaime, Sens. Actuators, B 2015, 218, 73.
  16. [17]J. N. Schönberg, V. Kondrashov, A. Prokhorov, J. Rühe, Sens. Actuators, B 2016, 222, 87.
  17. [18]K. Stephan, N. Zvezditza, N. Toshko, N. Nedyu, M. Machkova, Sens. Actuators, B 2015, 210, 676.
  18. [19]D. M. Li, J. J. Zhang, W. Wei, J. R. Zhou, S. P. Wen, S. P. Ruan, J. Mater. Sci.: Mater. Electron. 2015, 26, 3083.
  19. [20]M. R. Yang, K. S. Chen, Sens. Actuators, B 1998, 49, 240.
  20. [21]W. Yao, X. J. Chen, J. Zhang, Sens. Actuators, B 2010, 145, 327.
  21. [22]M. Q. Liu, C. Wang, Z. Yao, N. Y. Kim, RSC Adv. 2016, 6, 41580.
  22. [23]X. P. Wang, C. L. Zhao, J. H. Li, Y. X. Jin, M. P. Ye, S. Z. Jin, Opt. Commun. 2013, 308, 11.
  23. [24]M. J. Yuan, Y. Zhang, X. J. Zheng, B. Jiang, P. W. Li, S. F. Deng, Sens. Actuators, B 2015, 209, 252.
  24. [25]M. I. Azmer, Q. Zafar, Z. Ahmad, K. Sulaiman, RSC Adv. 2016, 6, 35387.
  25. [26]N. Leif, N. Gustav, M. Albert, S. Maria, Adv. Mater. 2011, 23, 3751.21739488
  26. [27]A. Hamed, G. Davood, Phys. E (Amsterdam, Neth.) 2015, 65, 106.
  27. [28]W. D. Lin, C. T. Liao, T. C. Chang, S. H. Chen, R. J. Wu, Sens. Actuators, B 2015, 209, 555.
  28. [29]D. M. Li, J. J. Zhang, L. Shen, W. Dong, C. H. Feng, C. X. Liu, S. P. Ru, RSC Adv. 2015, 5, 22879.
  29. [30]X. Wang, G. Li, R. Liu, H. Ding, T. Zhang, J. Mater. Chem. 2012, 22, 21824.
  30. [31]Y. Chen, P. Zhang, D. M. Li, F. L. Gao, C. H. Feng, S. P. Wen, S. P. Ruan, Sens. Actuators, B. 2015, 212, 242.
  31. [32]J. E. Yagoubi, G. Lubineau, F. Roger, J. Verdu, Polymer 2012, 53, 5582.
  32. [33]D. Z. Zhang, H. Y. Chang, P. Li, R. H. Liu, Q. Z. Xue, Sens. Actuators, B 2016, 225, 233.
  33. [34]X. W. Wang, Z. P. Xiong, Z. Liu, T. Zhang, Adv. Mater. 2015, 27, 1370. 25522328
  34. [35]H. Masuda, F. Hasegwa, S. Ono, J. Electrochem. Soc. 1997, 144, 127.
  35. [36]R. Srivastava, B. C. Yadav, Adv. Mater. Lett. 2012, 3, 197.
  36. [37]E. Traversa, Sens. Actuators, B 1995, 23, 135.
  37. [38]T. Seiyama, N. Yamazoe, H. H. Arai, Sens. Actuators 1983, 4, 85.
  38. [39]L. J. Kennedy, M. J. Umapathy, U. Aruldoss, Measurement 2015, 67, 1.
  39. [40]A. De Luca, S. Santra, R. Ghosh, S. Z. Ali, J. W. Gardner, P. K. Guhac, F. Udrea, Nanoscale 2016, 8, 4565. 26842731
  40. [41]P. C. Cavallo, D. Acevedo, M. C. Fuertes, G. J. A. A. Soler‐Illia, C. Barbero, Sens. Actuators, B 2015, 210, 574.

Cited by

Sorted by citations

Authors
Li, T., Li, L., Sun, H., Xu, Y., Wang, X., Luo, H., Liu, Z., & Zhang, T.
Affiliations
  • Chinese Academy of Sciences (CN)
  • Beijing Information Institute 61 Houchangchun Road Beijing 215123 P. R. China
  • Nanyang Technological University (SG)
Corresponding author
Zhang, Ting
Venue
Advanced Science
Publisher
Wiley
Published
2017-01-24
Volume
4
Issue
5
Pages
1600404-1600404
ISSN
2198-3844 (ISSN-L)
OpenAlex
W2581901598
Cited by
298
References
2
Citations by year
2026: 20 · 2025: 31 · 2024: 31 · 2023: 42 · 2022: 50 · 2021: 45 · 2020: 24 · 2019: 32 · 2018: 18 · 2017: 5
FWCI
8.98
Type
journal article
Language
en
Open access
Locations
  • Advanced Science (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DR-NTU (Nanyang Technological University) (submittedVersion)
Funders
  • China Postdoctoral Science Foundation (2015M571837)
  • Natural Science Foundation of Jiangsu Province (BK20150364)
  • National Natural Science Foundation of China (61574163)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
Keywords
flexible humidity sensor, polyvinyl alcohol, three-dimensional porous structure, relative humidity measurement, temperature-insensitive sensor, smart labels, conductance change

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review