The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Nanozyme-Mediated Dual Immunoassay Integrated with Smartphone for Use in Simultaneous Detection of Pathogens
Open accessAbstract
Nanozymes are an excellent class of optical reporters for the development of sensitive biosensors for widespread applications. In this study, mesoporous core-shell palladium@platinum (Pd@Pt) nanoparticles were synthesized and then applied as signal amplifier in a dual lateral flow immunoassay (LFIA) and integrated with a smartphone-based device for use in simultaneous detection of Salmonella Enteritidis and Escherichia coli O157:H7. After optimization, the limit of detections were calculated to be ∼20 cfu/mL for S. Enteritidis and ∼34 cfu/mL for E. coli O157:H7, respectively. The greatly improved sensitivity was contributed by the peroxidase-like catalytic activity of the Pd@Pt nanoparticles for signal enhancement and the parallel design of dual detection for eliminating the cross-interference. The estimated recoveries of the dual LFIA range from 91.44 to 117.00%, which indicated that the developed method is capable of detecting live bacteria in food samples. This approach provides an attractive platform for S. Enteritidis and E. coli O157:H7 detection using a smartphone-based device as the sole piece of equipment, indicating great promise for foodborne pathogen analysis or in-field food safety tracking.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kirk, M. D., Pires, S. M., Black, R. E., Caipo, M., Crump, J. A., Devleesschauwer, B., Döpfer, D., Fazil, A., Fischer-Walker, C. L., Hald, T., et al. (2015) · PLoS Medicine · doi:10.1371/journal.pmed.1001921 · Cited by 1,625
Posthuma-Trumpie, G. A., Korf, J., & van Amerongen, A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2287-2 · Cited by 1,540
Molecular Imprinting on Inorganic Nanozymes for Hundred-fold Enzyme Specificity
Zhang, Z., Zhang, X., Liu, B., & Liu, J. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.7b00601 · Cited by 666
Detection and Spatial Mapping of Mercury Contamination in Water Samples Using a Smart-Phone
Wei, Q., Nagi, R., Sadeghi, K., Feng, S., Yan, E., Ki, S. J., Caire, R., Tseng, D., & Ozcan, A. (2014) · ACS Nano · doi:10.1021/nn406571t · Cited by 400
Ngom, B., Guo, Y., Wang, X., & Bi, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3661-4 · Cited by 386
Recent Advances in Electrochemical Immunosensors
Wen, W., Yan, X., Zhu, C., Du, D., & Lin, Y. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04281 · Cited by 313
Self-citationSCALLAN, E., HOEKSTRA, R. M., MAHON, B. E., JONES, T. F., & GRIFFIN, P. M. (2015) · Epidemiology and Infection · doi:10.1017/s0950268814003185 · Cited by 296
Nagvenkar, A. P., & Gedanken, A. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b05354 · Cited by 239
Ataee‐Esfahani, H., Imura, M., & Yamauchi, Y. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201307126 · Cited by 225
Wang, Q., Zhang, X., Huang, L., Zhang, Z., & Dong, S. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b16034 · Cited by 224
Cell-phone-based measurement of TSH using Mie scatter optimized lateral flow assays
You, D. J., Park, T. S., & Yoon, J.-Y. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.07.014 · Cited by 208
The changing face of pathogen discovery and surveillance
Lipkin, W. I. (2013) · Nature Reviews Microbiology · doi:10.1038/nrmicro2949 · Cited by 167
Bimetallic nanoparticles: Preparation, properties, and biomedical applications
Nasrabadi, H. T., Abbasi, E., Davaran, S., Kouhi, M., & Akbarzadeh, A. (2014) · Artificial Cells Nanomedicine and Biotechnology · doi:10.3109/21691401.2014.953632 · Cited by 129
Graphene Oxide Quantum Dots as Novel Nanozymes for Alcohol Intoxication
Sun, A., Li, M., & Hu, X. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b00306 · Cited by 122
Chen, X., Su, B., Cai, Z., Chen, X., & Oyama, M. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.04.067 · Cited by 112
Novel Metal Nanomaterials and Their Catalytic Applications
Wang, J., & Gu, H. (2015) · Molecules · doi:10.3390/molecules200917070 · Cited by 110
Zhang, Y., Tan, C., Fei, R., Liu, X., Zhou, Y., Chen, J., Chen, H., Zhou, R., & Hu, Y. (2013) · Analytical Chemistry · doi:10.1021/ac4028774 · Cited by 107
Wang, Y., Qin, Z., Boulware, D. R., Pritt, B. S., Sloan, L. M., González, I. J., Bell, D., Rees-Channer, R. R., Chiodini, P. L., Chan, W. C. W., et al. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03406 · Cited by 106
Lateral-flow enzyme immunoconcentration for rapid detection of Listeria monocytogenes
Cho, I., & Irudayaraj, J. (2013) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-6742-3 · Cited by 101
Jiang, T., Song, Y., Du, D., Liu, X., & Lin, Y. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00019 · Cited by 101
Self-citationWang, Y., Zeinhom, M. M. A., Yang, M., Sun, R., Wang, S., Smith, J. N., Timchalk, C. A., Li, L., Lin, Y., & Du, D. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02139 · Cited by 82
Self-citationEnzyme-linked immuno-strip biosensor to detect Escherichia coli O157:H7
Park, S., Kim, H., Paek, S., Hong, J. W., & Kim, Y. (2008) · Ultramicroscopy · doi:10.1016/j.ultramic.2008.04.063 · Cited by 71
Hwang, J., Kwon, D., Lee, S.-H., & Jeon, S. (2016) · RSC Advances · doi:10.1039/c6ra05446c · Cited by 63
Hossain, M. F., & Park, J. Y. (2014) · Electroanalysis · doi:10.1002/elan.201400018 · Cited by 60
Catch and Release: Integrated System for Multiplexed Detection of Bacteria
Verbarg, J. M., Plath, W., Shriver‐Lake, L. C., Howell, P. B., Erickson, J. S., Golden, J. P., & Ligler, F. S. (2013) · Analytical Chemistry · doi:10.1021/ac303801v · Cited by 39
Facile synthesis of Pt/Pd nanodendrites for the direct oxidation of methanol
Wu, H. H., Mei, S., Cao, X., Zheng, J., Lin, M., Tang, J., Ren, F., Du, Y., Pan, Y., & Gu, H. (2014) · Nanotechnology · doi:10.1088/0957-4484/25/19/195702 · Cited by 30
Hu, J., Wei, T., Sun, S., Zhao, A., & Xu, C. (2015) · Anais da Academia Brasileira de Ciências · doi:10.1590/0001-3765201520140518 · Cited by 18
Cited by
A Review on Metal- and Metal Oxide-Based Nanozymes: Properties, Mechanisms, and Applications
Liu, Q., Zhang, A., Wang, R., Zhang, Q., & Cui, D. (2021) · Nano-Micro Letters · doi:10.1007/s40820-021-00674-8 · Cited by 745
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
Point-of-care diagnostics for infectious diseases: From methods to devices
Wang, C., Liu, M., Wang, Z., Li, S., Deng, Y., & He, N. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101092 · Cited by 622
Nanozyme chemiluminescence paper test for rapid and sensitive detection of SARS-CoV-2 antigen
Liu, D., Ju, C., Han, C., Shi, R., Chen, X., Duan, D., Yan, J., & Yan, X. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112817 · Cited by 321
A review on metal nanozyme-based sensing of heavy metal ions: Challenges and future perspectives
Unnikrishnan, B., Lien, C.-W., Chu, H.-W., & Huang, C.-C. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2020.123397 · Cited by 290
Metadata
- Authors
- Cheng, N., Song, Y., Zeinhom, M. M. A., Chang, Y.-C., Sheng, L., Li, H., Du, D., Li, L., Zhu, M.-J., Luo, Y., Xu, W., & Lin, Y.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-11-07
- Volume
- 9
- Issue
- 46
- Pages
- 40671-40680
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2756185868
- Cited by
- 301
- References
- 27
- FWCI
- 10.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.