The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Carbon Dots/g-C3N4 Nanoheterostructures-Based Signal-Generation Tags for Photoelectrochemical Immunoassay of Cancer Biomarkers Coupling with Copper Nanoclusters
Abstract
A class of 0-dimensional/2-dimensional (0 D /2D) nanoheterostructures based on carbon quantum dots (CQDs) and graphitic carbon nitride (g-C 3 N 4 ) was designed as the signal-generation tags for the sensitive photoelectrochemical (PEC) immunoassay of prostate-specific antigen (PSA) coupling with the copper nanoclusters (CuNCs). Combination of CQDs with g-C 3 N 4 promoted the photoexcited electron/hole separation and largely increased the photocurrents of the nanoheterostructures. Initially, a sandwich-type immunoreaction was carried out on monoclonal anti-PSA antibody-coated microplate by using PSA aptamer linked with CuNCs as the tracer. Accompanying the immunocomplex, the carried CuNCs were dissolved under acidic conditions. The as-released copper ions from the CuNCs could be captured onto the CQDs/g-C 3 N 4 nanoheterostructures via the amino-group on the CQD surface as well as the −NH x ( x = 1, 2, 3) of g-C 3 N 4 nanosheets. The strong coordination of the Lewis basic sites on the CQDs/g-C 3 N 4 with Cu 2+ decreased the photocurrent of the nanoheterostructures. Under optimal conditions, CQDs/g-C 3 N 4 nanoheterostructures displayed good photocurrent responses for the detection of PSA within the dynamic linear range of 0.02–100 ng mL –1 and a limit of detection (LOD) of 5.0 pg mL –1 . This method was also evaluated for quantitative screening of human PSA serum specimens by using the referenced electrochemiluminescent enzyme-linked immunoassay (ECL-ELIA) and gave good matched results between two methods. Additionally, this system was beneficial to explore the charge-separation and photoinduced electron transfer mechanism in the photoelectrochemical sensing protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metal-free efficient photocatalyst for stable visible water splitting via a two-electron pathway
Liu, J., Liu, Y., Liu, N., Han, Y., Zhang, X., Huang, H., Lifshitz, Y., Lee, S.-T., Zhong, J., & Kang, Z. (2015) · Science · doi:10.1126/science.aaa3145 · Cited by 4,468
Cited by
Asadzadeh-Khaneghah, S., & Habibi-Yangjeh, A. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.124319 · Cited by 476
Recent Developments of Carbon Dots in Biosensing: A Review
Ji, C., Zhou, Y., Leblanc, R. M., & Peng, Z. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01556 · Cited by 461
Review—Recent Advances in Carbon Nanomaterials as Electrochemical Biosensors
Kour, R., Arya, S., Young, S.-J., Gupta, V., Bandhoria, P., & Khosla, A. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab6bc4 · Cited by 424
Lv, S., Zhang, K., Zeng, Y., & Tang, D. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01825 · Cited by 348
Self-citationEmerging graphitic carbon nitride-based materials for biomedical applications
Liao, G., He, F., Li, Q., Zhong, L., Zhao, R., Che, H., Gao, H., & Fang, B. (2020) · Progress in Materials Science · doi:10.1016/j.pmatsci.2020.100666 · Cited by 340
Metadata
- Authors
- Lv, S., Li, Y., Zhang, K., Lin, Z., & Tang, D.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-10-24
- Volume
- 9
- Issue
- 44
- Pages
- 38336-38343
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2761299169
- Cited by
- 171
- References
- 1
- FWCI
- 6.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Carbon Dots/g-C3N4 Nanoheterostructures-Based Signal-Generation Tags for Photoelectrochemical Immunoassay of Cancer Biomarkers Coupling with Copper Nanoclusters. https://app.cochat.ai/papers/10.1021/acsami.7b13272
- The paper
- Lv, S., Li, Y., Zhang, K., Lin, Z., & Tang, D. (2017). Carbon Dots/g-C3N4 Nanoheterostructures-Based Signal-Generation Tags for Photoelectrochemical Immunoassay of Cancer Biomarkers Coupling with Copper Nanoclusters. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.7b13272
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.