The DOI matches its Crossref record.
Sulfur-Doped Graphene-Based Immunological Biosensing Platform for Multianalysis of Cancer Biomarkers
Abstract
The accurate tumor marker detection at an early stage can prevent people from getting cancer to a great extent. Herein, a novel tri-antibody dual-channel biosensing strategy is applied in multianalysis of carcino-embryonic antigen (CEA) and nuclear matrix protein 22 (NMP22). In this immunosensor fabrication process, graphene oxide/polyaniline nanostructures are used as matrix and mesoporous NKF-5-3 is used as labels. Two kinds of antigens can be obtained from the signals of neutral red and toluidine blue, respectively, which are modified on the labels. In this tri-antibody dual-channel biosensing platform, sulfur-doped graphene sheet is synthesized by click chemistry as the framework structure. Majority of the incubations are conducted in individual steps, which ensure the surface incubation more tightly. The detection limit of NMP22 and CEA are 25 and 30 fg/mL, respectively. The low detection limit and excellent stability can ascribe to the tri-antibody dual-channel strategy, which makes the sensor platform from surface to the space. The clinical urine sample analysis achieves a good performance. The urine-based test can avoid the secondary injury on hemophilia or ischemic patients, displaying a potential application in clinical diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors
Krishnan, S. K., Singh, E., Singh, P., Meyyappan, M., & Nalwa, H. S. (2019) · RSC Advances · doi:10.1039/c8ra09577a · Cited by 785
Bolotsky, A., Butler, D., Dong, C., Gerace, K., Glavin, N. R., Muratore, C., Robinson, J. A., & Ebrahimi, A. (2019) · ACS Nano · doi:10.1021/acsnano.9b03632 · Cited by 381
Song, D., Jiang, X., Li, Y., Lu, X., Luan, S., Wang, Y., Li, Y., & Gao, F. (2019) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2019.03.083 · Cited by 329
Sargazi, S., Fatima, I., Hassan Kiani, M., Mohammadzadeh, V., Arshad, R., Bilal, M., Rahdar, A., Díez-Pascual, A. M., & Behzadmehr, R. (2022) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2022.02.137 · Cited by 329
Origami multiple paper-based electrochemical biosensors for pesticide detection
Arduini, F., Cinti, S., Caratelli, V., Amendola, L., Palleschi, G., & Moscone, D. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.014 · Cited by 322
Metadata
- Authors
- Ren, X., Ma, H., Zhang, T., Zhang, Y., Yan, T., Du, B., & Wei, Q.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-10-18
- Volume
- 9
- Issue
- 43
- Pages
- 37637-37644
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2763819891
- Cited by
- 159
- References
- 0
- FWCI
- 11.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sulfur-Doped Graphene-Based Immunological Biosensing Platform for Multianalysis of Cancer Biomarkers. https://app.cochat.ai/papers/10.1021/acsami.7b13416
- The paper
- Ren, X., Ma, H., Zhang, T., Zhang, Y., Yan, T., Du, B., & Wei, Q. (2017). Sulfur-Doped Graphene-Based Immunological Biosensing Platform for Multianalysis of Cancer Biomarkers. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.7b13416
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.