The DOI matches its Crossref record; the references it cites are not checked yet.
Highly Sensitive and Reproducible SERS Sensor for Biological pH Detection Based on a Uniform Gold Nanorod Array Platform
Open accessAbstract
Conventional research on surface-enhanced Raman scattering (SERS)-based pH sensors often depends on nanoparticle aggregation, whereas the variability in nanoparticle aggregation gives rise to poor repeatability in the SERS signal. Herein, we fabricated a gold nanorod array platform via an efficient evaporative self-assembly method. The platform exhibits great SERS sensitivity with an enhancement factor of 5.6 × 10 7 and maintains excellent recyclability and reproducibility with relative standard deviation (RSD) values of less than 8%. On the basis of the platform, we developed a highly sensitive bovine serum albumin (BSA)-coated 4-mercaptopyridine (4-MPy)-linked (BMP) SERS-based pH sensor to report pH ranging from pH 3.0 to pH 8.0. The intensity ratio variation of 1004 and 1096 cm –1 in 4-MPy showed excellent pH sensitivity, which decreased as the surrounding pH increased. Furthermore, this BMP SERS-based pH sensor was employed to measure the pH value in C57BL/6 mouse blood. We have demonstrated that the pH sensor has great advantages such as good stability, reliability, and accuracy, which could be extended for the design of point-of-care devices.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The SERS peak intensities of 4-MPy at 1008 cm−1 and 1100 cm−1 vary during protonation or deprotonation, corresponding to pyridine ring breathing vibration and carbon-sulfur bond, respectively.
“The peak intensity at 1008 cm 1 and 1100 cm 1 varies during protonation or deprotonation process, corresponding to pyridine ring breathing vibration and carbon -sulfur bond, respectively. [34,35]”
From Multiplex Cellular Microenvironment Detection Based on Surface-Enhanced Raman Scattering Patch (2025) · cites this paper as [35]
Citations
The citation lists haven’t been fetched yet
References 40 · Cited by 113
Research works printed but not linked: 1
- 10.1021/ac981131+ · DOI
Metadata
- Authors
- Bi, L., Wang, Y., Yang, Y., Li, Y., Mo, S., Zheng, Q., & Chen, L.
- Affiliations
- Binzhou Medical University (CN)
- Yantai Institute of Coastal Zone Research (CN)
- Corresponding author
- Zheng, Qingyin
- Chen, Lingxin
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-04-17
- Volume
- 10
- Issue
- 18
- Pages
- 15381-15387
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2799833708
- Cited by
- 113
- References
- 40
- Citations by year
- 2026: 11 · 2025: 12 · 2024: 17 · 2023: 4 · 2022: 18 · 2021: 18 · 2020: 15 · 2019: 15 · 2018: 3
- FWCI
- 3.82
- Type
- journal article
- Language
- en
- Open access
- green
- ir.yic.ac.cn
- Licence
- cc-by-nc-sa
- Locations
- ACS Applied Materials & Interfaces (publishedVersion)
- PubMed (publishedVersion)
- Knowledge Repository of Yantai Institute of Coastal Zone Research, CAS (Yantai Institute of Coastal Zone Research) (submittedVersion)
- Knowledge Repository of Yantai Institute of Coastal Zone Research, CAS (Yantai Institute of Coastal Zone Research) (submittedVersion, cc-by-nc-sa)
- Funders
- Shandong Province (J16LK10)
- National Natural Science Foundation of China (51401031, 81530030, 81573393, 21575159, 21605005)
- Chinese Academy of Sciences (CXJJ-17-Q148)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
- Health Sciences › Medicine › Infectious Diseases › SARS-CoV-2 detection and testing
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Plasmonic and Surface Plasmon Research
- Keywords
- surface-enhanced Raman scattering, gold nanorod arrays, evaporation-induced self-assembly, 4-mercaptopyridine, bovine serum albumin, nanoparticle aggregation, signal reproducibility, blood pH measurement, point-of-care devices
- MeSH terms
- Animals, Gold, Hydrogen-Ion Concentration, Mice, Inbred C57BL, Spectrum Analysis, Raman, Reproducibility of Results, Nanotubes, Mice, Metal Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review