CoChat

Multiplex Cellular Microenvironment Detection Based on Surface-Enhanced Raman Scattering Patch

Open access
Wu, Xiaoyu, Zhang, Zhaodong, Zhu, Feng, Kuang, Yuanheng, Chen, Shuqi, Sun, Chongling, Liu, Bohua, Wang, Yanyan · 2025 · Chemistry–Methods

The DOI matches its Crossref record; 39 of the 40 references it cites were found in a registry or an index; 2 of the 13 sources its claims cite were checked for support.

Abstract

Monitoring cellular microenvironment is of vital significance to study cell process, reveal pathological state, and predict early disease. Herein, a surface‐enhanced Raman scattering (SERS) patch is proposed to sense the hydrogen peroxide (H2O2) concentration and pH variation of extracellular microenvironment in a multiplex manner. Scale‐up and ordered gold nanorods (AuNRs) assembly is introduced by interfacial assembly and absorption transferring on the flexible polydimethylsiloxane (PDMS) film, providing the patch with great SERS enhancement for biosensing. The modification of H2O2‐responsive and pH‐susceptive Raman reporter molecule endows the SERS patch with high sensitivity to multiple analytes, and the construction of multivariate curve resolution (MCR) analysis facilitates the quantification of H2O2 and pH value in spite of the characteristic peaks overlap. Furthermore, the SERS patch is used to compare the extracellular microenvironments of different living cells. Results demonstrate that highly migratory cells (i.e., MDA‐MB‐231) secreted more H2O2 under phorbol 12‐myristate 13‐acetate (PMA) stimulation, and the extracellular microenvironment is more acidic than the cells with weak migration ability (i.e., MCF‐7), revealing the relationship between cell migration and microenvironment. The strategy integrates H2O2 detection and pH determination in one patch, which may offer an approach for novel multiplex biosensor and cell migration investigation.

Overview

CoChat Summary

TL;DR

A flexible surface-enhanced Raman scattering (SERS) patch was fabricated by assembling gold nanorods on PDMS and functionalized with 2-MHQ and 4-MPy to detect H2O2 and pH in cell microenvironments. Multiplex quantification was achieved using multivariate curve resolution (MCR) to resolve overlapping Raman peaks, and the patch distinguished migratory MDA-MB-231 from MCF-7 breast cancer cells by their extracellular H2O2 and pH profiles.

Key findings

  • The optimized SERS patch used AuNR-M (aspect ratio 3.4, absorption peak 860 nm), showed an enhancement factor of 1.8×10^5, and had a relative standard deviation of 8.60% over a 28×28 μm² mapping area; signal was stable after one week in air.
  • Individual H2O2 detection with 2-MHQ gave a linear I990 versus log(H2O2) calibration (R² = 0.94) and a limit of detection of 0.14 nM; pH detection with 4-MPy gave a linear I1100/I1008 versus pH relationship.
  • In multiplex detection, overlap between 990 and 1008 cm⁻¹ prevented traditional I990 quantification, but MCR resolved H2O2 with RRSSQ = 4.7% and Cblue/Cgray versus log(H2O2) R² = 0.99, and pH with RRSSQ = 4.4% and Ccyan/Corange versus pH R² = 0.98; four-component MCR gave H2O2 R² = 0.98.
  • Under PMA stimulation, MDA-MB-231 cells showed higher H2O2-related contribution ratio and lower pH-related contribution ratio than MCF-7 cells (ANOVA with Tukey, *P < 0.001), and MDA-MB-231 had higher migration ability with complete wound healing within 48 h.

Methods

  • The SERS patch was made by interfacial assembly of AuNRs with perfluorodecanethiol, ethanol, and hexane, followed by absorption transferring onto a flexible PDMS film and plasma treatment; AuNRs with different aspect ratios were compared using 4-MBA (10 mM) SERS spectra.
  • H2O2 sensing used 2-mercaptohydroquinone (2-MHQ, 50 mM), pH sensing used 4-mercaptopyridine (4-MPy, 10 mM), and multiplex detection modified both reporters sequentially on the same patch.
  • SERS spectra were collected with a Renishaw Raman microscope (785 nm laser, 3.2 mW, 50× objective, 2 s integration, 2 accumulations); H2O2 ranged from 1 nM to 1 mM and pH from 6 to 8. MCR decomposition used PLS Toolbox with noise correction factor 3 and weighted least squares for nonnegative contributions. Cell experiments used MCF-7 and MDA-MB-231 cells cultured in DMEM with 10% FBS, seeded at 1×10^5/mL, stimulated with PMA (5 μg/mL), and migration assessed by scratch test with Calcein-AM staining and confocal imaging every 24 h.

Limitations

  • The paper does not include a dedicated limitations section. It states that spectra overlap between 990 and 1008 cm⁻¹ hinders traditional intensity-based H2O2 quantification in multiplex detection, which motivated the MCR approach.
  • Evident from the text: the four-component MCR multiplex analysis relies on an equality constraint using known pure component spectra, so it depends on prior calibration; the cell study compares only two breast cancer cell lines under PMA stimulation, reports extracellular rather than intracellular measurements, and uses small sample sizes (n = 5–6).

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1002/cmtd.202400083

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Fabrication and characterization of our SERS-based plasmonic patch. A) Fabrication process of the plasmonic patch by modifying AuNRs on PDMS film by interfacial assembly and absorption transferring. B) Images of AuNRs solution, AuNRs film on water-hexane interface and plasmonic patch of AuNRs-modified PDMS film. C) SEM images of the plasmonic patch. D) UV -Vis absorption spectra of AuNRs with different AR. E) SERS spectra, and F) intensity at 1075 cm  1 of 4-MBA (10 mM) on the plasmonic patch fabricated by different AuNRs. AuNR-S (blue): AR is 1.6. AuNR-M (red): AR is 3.4. AuNR-L (brown): AR is 5.0.
Figure 1 Fabrication and characterization of our SERS-based plasmonic patch. A) Fabrication process of the plasmonic patch by modifying AuNRs on PDMS film by interfacial assembly and absorption transferring. B) Images of AuNRs solution, AuNRs film on water-hexane interface and plasmonic patch of AuNRs-modified PDMS film. C) SEM images of the plasmonic patch. D) UV -Vis absorption spectra of AuNRs with different AR. E) SERS spectra, and F) intensity at 1075 cm 1 of 4-MBA (10 mM) on the plasmonic patch fabricated by different AuNRs. AuNR-S (blue): AR is 1.6. AuNR-M (red): AR is 3.4. AuNR-L (brown): AR is 5.0.CC-BY · From the PDF
Figure 2 H2O2 and pH detection by spectra relative intensity using the SERS patch. A) Scheme of H2O2 detection by 2-MHQ oxidation. B) Normalized SERS spectra of 2-MHQ after reacting with H2O2 in different concentrations (a -g: 0 nM, 1 nM, 10 nM, 100 nM, 1 μ M, 10 μ M, 100 μ M). C) The relationship between I 990 and log(H2O2) corresponding to B. D) Scheme of pH detection by 4-MPy protonation and deprotonation. E) Normalized SERS spectra of 4-MPy in PBS solutions with different pH values (a -e: 6.2, 6.6, 7.0, 7.4, 7.8). F) The relationship between I 1100 / I 1008 and pH values corresponding to E. G) Scheme of multiplex detection by modifying 2-MHQ and 4-MPy on the SERS patch. H) Normalized SERS spectra of the patch in PBS solution with varying H2O2 concentrations (a -e: 1 nM, 10 nM, 100 nM, 1 μ M, 10 μ M) and constant pH value (6.9). I) I 990 versus log(H2O2) corresponding to H. The data are indicated as mean  standard deviation ( n = 6). Inset is the enlarged spectrum of H.
Figure 2 H2O2 and pH detection by spectra relative intensity using the SERS patch. A) Scheme of H2O2 detection by 2-MHQ oxidation. B) Normalized SERS spectra of 2-MHQ after reacting with H2O2 in different concentrations (a -g: 0 nM, 1 nM, 10 nM, 100 nM, 1 μ M, 10 μ M, 100 μ M). C) The relationship between I 990 and log(H2O2) corresponding to B. D) Scheme of pH detection by 4-MPy protonation and deprotonation. E) Normalized SERS spectra of 4-MPy in PBS solutions with different pH values (a -e: 6.2, 6.6, 7.0, 7.4, 7.8). F) The relationship between I 1100 / I 1008 and pH values corresponding to E. G) Scheme of multiplex detection by modifying 2-MHQ and 4-MPy on the SERS patch. H) Normalized SERS spectra of the patch in PBS solution with varying H2O2 concentrations (a -e: 1 nM, 10 nM, 100 nM, 1 μ M, 10 μ M) and constant pH value (6.9). I) I 990 versus log(H2O2) corresponding to H. The data are indicated as mean  standard deviation ( n = 6). Inset is the enlarged spectrum of H.CC-BY · From the PDF
Image 3
CC-BY · From the PDF
Figure 4 Multiplex detection of living cells with different migration ability using the SERS patch and MCR analysis. A) Normalized SERS spectra of MCF-7 before (black) and after (blue) PMA stimulation. B) Normalized SERS spectra of MDA-MB-231 before (black) and after (green) PMA stimulation. C) C blue / C gray and D) C cyan / C orange of different cells corresponding to SERS spectra in A and B. ANOVA with Tukey: *** P < 0.001. E) Scatter of contribution ratio C blue / C gray (set as x) and C cyan / C orange (set as y) determined by MCR decomposition. F) Cell migration rate estimated by scratch test. The data are indicated as mean  standard deviation ( n = 5). G) Fluorescence images of MCF-7 cells and MDA-MB-231 cells in scratch test. Scale bar is 200 μ m.
Figure 4 Multiplex detection of living cells with different migration ability using the SERS patch and MCR analysis. A) Normalized SERS spectra of MCF-7 before (black) and after (blue) PMA stimulation. B) Normalized SERS spectra of MDA-MB-231 before (black) and after (green) PMA stimulation. C) C blue / C gray and D) C cyan / C orange of different cells corresponding to SERS spectra in A and B. ANOVA with Tukey: *** P < 0.001. E) Scatter of contribution ratio C blue / C gray (set as x) and C cyan / C orange (set as y) determined by MCR decomposition. F) Cell migration rate estimated by scratch test. The data are indicated as mean  standard deviation ( n = 5). G) Fluorescence images of MCF-7 cells and MDA-MB-231 cells in scratch test. Scale bar is 200 μ m.CC-BY · From the PDF

Verification

Claims the paper makes

2 Valid · 0 Not valid · 9 Not checked · 30 Own results and interpretations

14 more claims

Create a free account to see all 41 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 4
  • It may state two separate claims as one. 20

Create a free account to see these claims.

Citations

Cites

Show all 39 references

Research works printed but not linked: 3

  1. S. S. Timilsina, P. Jolly, N. Durr, M. Yafia, D. E. Ingber, Acc. Chem. Res. 2021 , 54 , 3529.
  2. X. Y. Wu, R. Y. Feng, F. Zhu, Z. D. Zhang, Q. N. Li, X. J. Chen, Y. Y. Wang, in 2024 IEEE Sensors Conf. , IEEE, Kobe, Japan 2024 .
  3. X. Y. Wu, F. Zhu, Y. H. Kuang, B. H. Liu, C. L. Sun, Y. Y. Wang, Chem. J. Chin. Univ. 2025 , 46 , 20240364.

Metadata

Authors
Wu, X., Zhang, Z., Zhu, F., Kuang, Y., Chen, S., Sun, C., Liu, B., & Wang, Y.
Affiliations
Tianjin University (CN)
Corresponding author
Wang, Yanyan
Venue
Chemistry–Methods
Publisher
Wiley
Published
2025-05-02
Volume
5
Issue
7
ISSN
2628-9725 (ISSN-L)
OpenAlex
W4410035710
Cited by
0
References
40
FWCI
0.00
Type
journal article
Language
en
Open access
Locations
Chemistry - Methods (publishedVersion, cc-by)
Funders
National Natural Science Foundation of China (32371471)
Topics
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
Keywords
surface-enhanced Raman scattering, extracellular microenvironment, hydrogen peroxide detection, pH sensing, gold nanorods, polydimethylsiloxane, multivariate curve resolution, cell migration, MDA-MB-231 cells, MCF-7 cells, phorbol myristate acetate, Raman reporter molecules

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-12, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-12 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multiplex Cellular Microenvironment Detection Based on Surface-Enhanced Raman Scattering Patch. https://app.cochat.ai/papers/10.1002/cmtd.202400083
The paper
Wu, X., Zhang, Z., Zhu, F., Kuang, Y., Chen, S., Sun, C., Liu, B., & Wang, Y. (2025). Multiplex Cellular Microenvironment Detection Based on Surface-Enhanced Raman Scattering Patch. Chemistry–Methods. https://doi.org/10.1002/cmtd.202400083

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.