The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Magnetic Nanozyme-Linked Immunosorbent Assay for Ultrasensitive Influenza A Virus Detection
Abstract
Rapid and sensitive detection of influenza virus is of soaring importance to prevent further spread of infections and adequate clinical treatment. Herein, an ultrasensitive colorimetric assay called magnetic nano(e)zyme-linked immunosorbent assay (MagLISA) is suggested, in which silica-shelled magnetic nanobeads (MagNBs) and gold nanoparticles are combined to monitor influenza A virus up to femtogram per milliliter concentration. Two essential strategies for ultrasensitive sensing are designed, i.e., facile target separation by MagNBs and signal amplification by the enzymelike activity of gold nanozymes (AuNZs). The enzymelike activity was experimentally and computationally evaluated, where the catalyticity of AuNZ was tremendously stronger than that of normal biological enzymes. In the spiked test, a straightforward linearity was presented in the range of 5.0 × 10 –15 –5.0 × 10 –6 g·mL –1 in detecting the influenza virus A (New Caledonia/20/1999) (H1N1). The detection limit is up to 5.0 × 10 –12 g·mL –1 only by human eyes, as well as up to 44.2 × 10 –15 g·mL –1 by a microplate reader, which is the lowest record to monitor influenza virus using enzyme-linked immunosorbent assay-based technology as far as we know. Clinically isolated human serum samples were successfully observed at the detection limit of 2.6 PFU·mL –1 . This novel MagLISA demonstrates, therefore, a robust sensing platform possessing the advances of fathomable sample separation, enrichment, ultrasensitive readout, and anti-interference ability may reduce the spread of influenza virus and provide immediate clinical treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lab on a chip for continuous-flow magnetic cell separation
Hejazian, M., Li, W., & Nguyen, N.-T. (2015) · Lab on a Chip · doi:10.1039/c4lc01422g · Cited by 347
Cited by
Nanomaterials with enzyme-like characteristics (nanozymes): next-generation artificial enzymes (II)
Wu, J., Wang, X., Wang, Q., Lou, Z., Li, S., Zhu, Y., Qin, L., & Wei, H. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00457a · Cited by 4,108
Nanozymes: Classification, Catalytic Mechanisms, Activity Regulation, and Applications
Huang, Y., Ren, J., & Qu, X. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00672 · Cited by 3,523
A Review on Metal- and Metal Oxide-Based Nanozymes: Properties, Mechanisms, and Applications
Liu, Q., Zhang, A., Wang, R., Zhang, Q., & Cui, D. (2021) · Nano-Micro Letters · doi:10.1007/s40820-021-00674-8 · Cited by 745
Wang, J., Huang, R., Qi, W., Su, R., Binks, B. P., & He, Z. (2019) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2019.05.012 · Cited by 489
Gold Nanozymes: From Concept to Biomedical Applications
Lou-Franco, J., Das, B., Elliott, C., & Cao, C. (2021) · Nano-Micro Letters · doi:10.1007/s40820-020-00532-z · Cited by 329
Metadata
- Authors
- Oh, S., Kim, J., Tran, V. T., Lee, D. K., Ahmed, S. R., Hong, J. C., Lee, J., Park, E. Y., & Lee, J.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-03-29
- Volume
- 10
- Issue
- 15
- Pages
- 12534-12543
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2795172059
- Cited by
- 176
- References
- 1
- FWCI
- 7.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.