Abstract
We review the fundamental physics in continuous-flow magnetic cell separation and identify the optimisation parameters of LOC devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In our microfluidic chip, the drag force and the magnetic force were dominant forces for the magnetic bead-labelled cells (Fig. 1B).”
From Dynamic Halbach array magnet integrated microfluidic system for the continuous-flow separation of rare tumor cells (2019) · cites this paper as [21]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Connolly, J., Jones, S. K., & Dobson, J. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/201 · Cited by 5,881
Ghaffari, S., Chandorkar, S. A., Wang, S., Ng, E. J., Ahn, C. H., Hong, V., Yang, Y., & Kenny, T. W. (2014) · Scientific Reports · doi:10.1038/srep04331 · Cited by 1,521
Pamme, N. (2006) · Lab Chip · doi:10.1039/b513005k · Cited by 1,129
Label-free cell separation and sorting in microfluidic systems
Gossett, D. R., Weaver, W. M., Mach, A. J., Hur, S. C., Tse, H. T. K., Lee, W., Amini, H., & Di Carlo, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3721-9 · Cited by 930
Continuous flow separations in microfluidic devices
Pamme, N. (2007) · Lab on a Chip · doi:10.1039/b712784g · Cited by 770
Magnetic bead handling on-chip: new opportunities for analytical applications
Gijs, M. A. M. (2004) · Microfluidics and Nanofluidics · doi:10.1007/s10404-004-0010-y · Cited by 749
Microfluidic Applications of Magnetic Particles for Biological Analysis and Catalysis
Gijs, M. A. M., Lacharme, F., & Lehmann, U. (2010) · Chemical Reviews · doi:10.1021/cr9001929 · Cited by 679
Microfluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Magnetic nanoparticles: recent advances in synthesis, self-assembly and applications
Singamaneni, S., Bliznyuk, V. N., Binek, C., & Tsymbal, E. Y. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm11845e · Cited by 537
Continuous separation of cells and particles in microfluidic systems
Lenshof, A., & Laurell, T. (2010) · Chemical Society Reviews · doi:10.1039/b915999c · Cited by 528
Research works printed but not linked: 20
- V. Sahore and I. Fritsch, American Chemical Society, 2013, 85, 11809-11816.
- M. A. M. Gijs, Microfluid Nanofluid, 2004, 1, 22-40.
- J. Berthier, and P. Silberzan, Microfluidics for biotechnology, 2nd edition, 2010, ARTECH HOUSE
- R. Gelszinnis, M. Faivre, J. Degouttes, N. Terrier, R. Ferrigno and A.-L. Deman, 17th International Conference on Miniaturized Systems for Chemistry and Life Sciences 27-31 October 2013, Freiburg, Germany.
- B. Babic, R. Ghai, and K. Dimitrov, Proc. SPIE 6799, BioMEMS and Nanotechnology III, 67990U (December 27, 2007).
- J. Kim, U. Steinfeld, H.-H. Lee and H. Seidel, IEEE SENSORS IEEE SENSORS 2007 Conference, 2007.
- L. Liang, J. Zhu and X. Xuan, BIOMICROFLUIDICS, 2011, 5.
- L. Liang and X. Xuan, Biomicrofluidics, 2012, 6.
- J. Zeng, C. Chen, P. Vedantam, V. Brown, T.-R. J. Tzeng and X. Xuan, J. Micromech. Microeng., 2012, 22.
- H.-K. Seo, Y.-H. Kim, H.-O. Kim and Y.-J. Kim, J. Micromech. Microeng., 2010, 20.
- J. Siegrist, L. Zavattoni, R. Burger and J. Ducrée, Transducers'1111, Beijing, China, June 5-9, 2011.
- H.-K. Seo, H.-O. Kim and Y.-J. Kim, Proceedings of 10th IEEE international conference on nanotechnology joint symposium with nano korea 2010, 911-914.
- K.-H. Han and A. B. Frazier, NSTI-Nanotech 2005, 2005.
- K.-H. Han and A. B. Frazier, JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2005, 14, 1057- 7157.
- O. Yassine, C. P. Gooneratne, D. Abu Smara, F. Li, H. Mohammed, J. Merzaban and J. Kosel, Biomicrofluidics, 2014, 8.
- M. Glynn, D. Kirby, D. Chung, D. J. Kinahan, G. Kijanka and J. Ducrée, Journal of Laboratory Automation, 2013.
- M. Karlel, J. Miwa, G. Roth, R. Zengerle and F. von Stetten, Micro Electro Mechanical Systems, 2009. MEMS 2009. IEEE 22nd International Conference on, 2009.
- M. Mizuno, M. Yamada, R. Mitamura, K. Ike, K. Toyama, M. Seki, Analytical Chemistry, 2013, 85, 7666-7673. · DOI
- A. F. Sousa, J. Loureiro, M. M. Diogo, J. M. S. Cabral and P. P. Freitas, Bioengineering (ENBENG), 2011. ENBENG 2011. 1st Portuguese Meeting in 1-4 March 2011, 2011, 1 -4.
- J. Jung and K.-H. Han, Transducers 2009, Denver, CO, USA, June 21-25, 2009, 2009.
Cited by
Metal–Organic Framework-Based Enzyme Biocomposites
Liang, W., Wied, P., Carraro, F., Sumby, C. J., Nidetzky, B., Tsung, C.-K., Falcaro, P., & Doonan, C. J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01029 · Cited by 784
Advances in Magnetic Nanoparticles for Biomedical Applications
Cardoso, V. F., Francesko, A., Ribeiro, C., Bañobre‐López, M., Martins, P., & Lanceros‐Mendez, S. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700845 · Cited by 723
Magnetic nanoparticles in nanomedicine: a review of recent advances
Wu, K., Su, D., Liu, J., Saha, R., & Wang, J.-P. (2019) · Nanotechnology · doi:10.1088/1361-6528/ab4241 · Cited by 509
Khan, F. S. A., Mubarak, N. M., Tan, Y. H., Khalid, M., Karri, R. R., Walvekar, R., Abdullah, E. C., Nizamuddin, S., & Mazari, S. A. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.125375 · Cited by 371
Particle manipulations in non-Newtonian microfluidics: A review
Lu, X., Liu, C., Hu, G., & Xuan, X. (2017) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2017.04.019 · Cited by 289
“, acoustic [17], electric [18], magnetic [19] or optical [20]), the passive manipulation exploits the flowinduced intrinsic lift and/or drag force to control particle motion with several advantages such as simplicity and autonomy [21].”
Background
Metadata
- Authors
- Hejazian, M., Li, W., & Nguyen, N.-T.
- Affiliations
- Griffith University (AU)
- University of Wollongong (AU)
- Corresponding author
- Nguyen, Nam-Trung
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2015
- Volume
- 15
- Issue
- 4
- Pages
- 959-970
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2152719918
- Cited by
- 347
- References
- 70
- Citations by year
- 2026: 16 · 2025: 14 · 2024: 15 · 2023: 24 · 2022: 30 · 2021: 42 · 2020: 35 · 2019: 47 · 2018: 44 · 2017: 28 · 2016: 40 · 2015: 12
- FWCI
- 2.28
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Research Online (University of Wollongong) (submittedVersion)
- Griffith Research Online (submittedVersion)
- Funders
- Griffith University
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrowetting and Microfluidic Technologies
- Keywords
- magnetic cell separation, continuous-flow microfluidics, magnetic force, particle separation, microfluidic device design, biocompatibility
- MeSH terms
- Cell Separation, Humans, Lab-On-A-Chip Devices, Magnetic Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lab on a chip for continuous-flow magnetic cell separation. https://app.cochat.ai/papers/10.1039/c4lc01422g
- The paper
- Hejazian, M., Li, W., & Nguyen, N.-T. (2015). Lab on a chip for continuous-flow magnetic cell separation. Lab on a Chip. https://doi.org/10.1039/c4lc01422g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.