CoChat

Hierarchical 3D Reduced Graphene Porous-Carbon-Based PCMs for Superior Thermal Energy Storage Performance

Li, Ang, Dong, Cheng, Dong, Wenjun, Atinafu, Dimberu G., Gao, Hongyi, Chen, Xiao, Wang, Ge · 2018 · ACS Applied Materials & Interfaces

The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.

Abstract

Phase change enthalpy and thermal conductivity are the two essential parameters for practical applications of shape-stabilized phase change materials (ss-PCMs). Herein, hierarchical three-dimensional (3D) reduced graphene porous carbon support PCMs have been successfully synthesized by carbonizing a graphene oxide@metal–organic framework (GO@MOF) template, which simultaneously realizes large phase change enthalpy and high thermal conductivity. During the carbonization process, MOFs were converted into hierarchical porous carbons, whereas GO was reduced to high-thermal-performance reduced graphene (rGO). Thus, a hierarchical 3D porous carbon structure with high porosity and large specific surface area was obtained, which provided a suitable condition for encapsulating PCMs. Furthermore, the pores of carbon stabilized the PCMs by capillary force and surface tension. The interaction between the PCM molecule and rGO significantly decreased the interfacial thermal resistance and made the composites reveal high thermal conductivity. Furthermore, the 3D network structure promoted the stretching and crystallization characteristics of the stearic acid molecule in the confined pore space, which enhanced the heat release efficiency. Compared with the rGO/MOF-5-C support, the hierarchical 3D structure of rGO@MOF-5-C revealed a thermal conductivity of 0.60 ± 0.02 W m –1 K –1, which was 27.7% improvement, with large phase change latent heat of 168.7 J g –1, which increased by 18.5%. Additionally, the obtained ss-PCMs showed transient thermal response and good durability, indicating its promising potential in thermal energy storage application.

Overview

Integrity signals

Registry

Crossref · 10.1021/acsami.8b09541

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 50 references

Cited by

Metadata

Authors
Li, A., Dong, C., Dong, W., Atinafu, D. G., Gao, H., Chen, X., & Wang, G.
Affiliations
  • Suzhou University of Science and Technology (CN)
  • Beijing Advanced Innovation Center for Materials Genome Engineering, Beijing Key Laboratory of Function Materials for Molecule & Structure Construction, School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083, China
  • University of Science and Technology Beijing (CN)
Corresponding author
  • Dong, Wenjun
  • Wang, Ge
Venue
ACS Applied Materials & Interfaces
Published
2018-08-30
Volume
10
Issue
38
Pages
32093-32101
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2889087964
Cited by
115
References
50
Citations by year
2026: 6 · 2025: 16 · 2024: 7 · 2023: 16 · 2022: 18 · 2021: 20 · 2020: 16 · 2019: 15 · 2018: 1
FWCI
8.31
Type
journal article
Language
en
Open access
closed
Locations
  • ACS Applied Materials & Interfaces (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Ministry of Education of the People's Republic of China (FRF-AS-17-006)
  • National Natural Science Foundation of China (51572022, 51436001)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Phase Change Materials Research
  • Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
  • Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
Keywords
shape-stabilized phase change materials, thermal energy storage, reduced graphene oxide, metal-organic frameworks, stearic acid, latent heat, thermal conductivity, interfacial thermal resistance, capillary confinement, MOF-5, carbonization, transient thermal response

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.