The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electrochemical Determination of Adrenaline Using MXene/Graphite Composite Paste Electrodes
Abstract
MXene/graphite composite paste electrode (MXene/GCPE)-based electrochemical sensor has been fabricated for the detection of adrenaline. The electrode exhibits a sensitive response to adrenaline in phosphate buffer solution of pH 7.4, and its catalytic activity is much higher than that of the bare graphite paste electrode. The electron-transfer reaction of MXene/GCPE is a diffusion controlled process. The graph of concentration of adrenaline with the peak current exhibits two linearities, one in the lower and other in the higher concentration range with a detection limit of 9.5 nM. The simultaneous analyses of adrenaline, ascorbic acid, and serotonin reveal that the fabricated electrode could separate the overlapped cyclic voltammetric peaks of these ternary mixtures. This electrode has been further employed in the detection of adrenaline in pharmaceutical samples with 99.2-100.8% recoveries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adrenaline: insights into its metabolic roles in hypoglycaemia and diabetes
Verberne, A. J. M., Korim, W. S., Sabetghadam, A., & Llewellyn‐Smith, I. J. (2016) · British Journal of Pharmacology · doi:10.1111/bph.13458 · Cited by 99
Cited by
Ti3C2TX MXene for Sensing Applications: Recent Progress, Design Principles, and Future Perspectives
Pei, Y., Zhang, X., Hui, Z., Zhou, J., Huang, X., Sun, G., & Huang, W. (2021) · ACS Nano · doi:10.1021/acsnano.1c00248 · Cited by 799
Synthesis, structure, properties and applications of MXenes: Current status and perspectives
Ronchi, R. M., Arantes, J. T., & Santos, S. F. (2019) · Ceramics International · doi:10.1016/j.ceramint.2019.06.114 · Cited by 698
2D Transition Metal Carbides (MXenes): Applications as an Electrically Conducting Material
Shahzad, F., Iqbal, A., Kim, H., & Koo, C. M. (2020) · Advanced Materials · doi:10.1002/adma.202002159 · Cited by 451
Deshmukh, K., Kovářík, T., & Khadheer Pasha, S. K. (2020) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213514 · Cited by 282
Metadata
- Authors
- Shankar, S. S., Shereema, R. M., & Rakhi, R. B.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-11-22
- Volume
- 10
- Issue
- 50
- Pages
- 43343-43351
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2900689732
- Cited by
- 184
- References
- 1
- FWCI
- 5.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical Determination of Adrenaline Using MXene/Graphite Composite Paste Electrodes. https://app.cochat.ai/papers/10.1021/acsami.8b11741
- The paper
- Shankar, S. S., Shereema, R. M., & Rakhi, R. B. (2018). Electrochemical Determination of Adrenaline Using MXene/Graphite Composite Paste Electrodes. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.8b11741
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.