Epidermis-Inspired Ultrathin 3D Cellular Sensor Array for Self-Powered Biomedical Monitoring
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Sensing devices with wearability would open the door to many advanced applications including soft robotics, artificial intelligence, and healthcare monitoring. Here, inspired by the configuration of the human epidermis, we present a flexible three-dimensional (3D) cellular sensor array (CSA) via a one-step thermally induced phase separation method. The CSA was framed by the 3D cellular electret with caged piezoelectric nanoparticles, which was ultrathin (80 μm), lightweight, and highly robust. For biomedical sensing, the 3D-CSA holds a decent pressure sensitivity up to 0.19 V kPa –1 with a response time of less than 16 ms. Owing to its rigid structural symmetry, the 3D-CSA could be identically operated from its both sides. It was demonstrated to successfully measure the human heartbeat, detect the eyeball motion for sleeping monitoring, and tactile imaging. Mimicking the functionalities of the human skin with a self-powered operation feature, the 3D-CSA was expected to represent a substantial advancement in wearable electronics for healthcare.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922
Self-citationFlexible triboelectric generator
Fan, F.-R., Tian, Z.-Q., & Lin Wang, Z. (2012) · Nano Energy · doi:10.1016/j.nanoen.2012.01.004 · Cited by 6,705
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Pursuing prosthetic electronic skin
Chortos, A., Liu, J., & Bao, Z. (2016) · Nature Materials · doi:10.1038/nmat4671 · Cited by 2,396
Piezoelectricity of single-atomic-layer MoS2 for energy conversion and piezotronics
Wu, W., Wang, L., Li, Y., Zhang, F., Lin, L., Niu, S., Chenet, D., Zhang, X., Hao, Y., Heinz, T. F., et al. (2014) · Nature · doi:10.1038/nature13792 · Cited by 2,287
Self-citationThe rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Xu, S., Zhang, Y., Cho, J., Lee, J., Huang, X., Jia, L., Fan, J. A., Su, Y., Su, J., Zhang, H., et al. (2013) · Nature Communications · doi:10.1038/ncomms2553 · Cited by 1,404
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Soft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
Xu, S., Zhang, Y., Jia, L., Mathewson, K. E., Jang, K.-I., Kim, J., Fu, H., Huang, X., Chava, P., Wang, R., et al. (2014) · Science · doi:10.1126/science.1250169 · Cited by 1,199
Wu, W., Wen, X., & Wang, Z. L. (2013) · Science · doi:10.1126/science.1234855 · Cited by 931
Self-citation
Cited by
Lim, H., Kim, H. S., Qazi, R., Kwon, Y., Jeong, J., & Yeo, W. (2020) · Advanced Materials · doi:10.1002/adma.201901924 · Cited by 1,002
Pyo, S., Lee, J., Bae, K., Sim, S., & Kim, J. (2021) · Advanced Materials · doi:10.1002/adma.202005902 · Cited by 631
Yang, Y., Pan, H., Xie, G., Jiang, Y., Chen, C., Su, Y., Wang, Y., & Tai, H. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2019.111789 · Cited by 496
Ti3C2Tx MXene-Reduced Graphene Oxide Composite Electrodes for Stretchable Supercapacitors
Zhou, Y., Maleski, K., Anasori, B., Thostenson, J. O., Pang, Y., Feng, Y., Zeng, K., Parker, C. B., Zauscher, S., Gogotsi, Y., et al. (2020) · ACS Nano · doi:10.1021/acsnano.9b10066 · Cited by 459
Nanogenerators for smart cities in the era of 5G and Internet of Things
Zhao, X., Askari, H., & Chen, J. (2021) · Joule · doi:10.1016/j.joule.2021.03.013 · Cited by 436
Self-citation
Metadata
- Authors
- Yan, C., Deng, W., Jin, L., Yang, T., Wang, Z., Chu, X., Su, H., Chen, J., & Yang, W.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-11-06
- Volume
- 10
- Issue
- 48
- Pages
- 41070-41075
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2899692486
- Cited by
- 155
- References
- 14
- FWCI
- 8.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Epidermis-Inspired Ultrathin 3D Cellular Sensor Array for Self-Powered Biomedical Monitoring. https://app.cochat.ai/papers/10.1021/acsami.8b14514
- The paper
- Yan, C., Deng, W., Jin, L., Yang, T., Wang, Z., Chu, X., Su, H., Chen, J., & Yang, W. (2018). Epidermis-Inspired Ultrathin 3D Cellular Sensor Array for Self-Powered Biomedical Monitoring. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.8b14514
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.