The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Thermally Activated Delayed Fluorescence Carbonyl Derivatives for Organic Light-Emitting Diodes with Extremely Narrow Full Width at Half-Maximum
Abstract
Two novel thermally activated delayed fluorescence (TADF) emitters, 3-phenylquinolino[3,2,1- de ]acridine-5,9-dione (3-PhQAD) and 7-phenylquinolino[3,2,1- de ]acridine-5,9-dione (7-PhQAD), were designed and synthesized based on a rigid quinolino[3,2,1- de ]acridine-5,9-dione (QAD) framework. With the effective superimposed resonance effect from electron-deficient carbonyls and electron-rich nitrogen atom, both emitters realize significant TADF characteristics with small Δ E ST s of 0.18 and 0.19 eV, respectively. And, molecular relaxations were dramatically suppressed for both emitters because of their conjugated structure. In the devices, 3-PhQAD realizes superior performance with a maximum external quantum efficiency (EQE) of 19.1% and a narrow full width at half-maximum (FWHM) of 44 nm, whereas a maximum EQE of 18.7% and an extremely narrow FWHM of 34 nm are realized for 7-PhQAD. These superior results reveal that apart from nitrogen and boron-aromatic systems, QAD framework can also act as a TADF matrix with effective resonance effect, and QAD derivatives are ideal candidates to develop TADF emitters with narrow FWHMs for practical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recent advances in organic thermally activated delayed fluorescence materials
Yang, Z., Mao, Z., Xie, Z., Zhang, Y., Liu, S., Zhao, J., Xu, J., Chi, Z., & Aldred, M. P. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00368k · Cited by 2,395
Samanta, P. K., Kim, D., Coropceanu, V., & Brédas, J.-L. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.6b12124 · Cited by 1,025
Cited by
Madayanad Suresh, S., Hall, D., Beljonne, D., Olivier, Y., & Zysman‐Colman, E. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201908677 · Cited by 752
Narrowband Emissive Thermally Activated Delayed Fluorescence Materials
Kim, H. J., & Yasuda, T. (2022) · Advanced Optical Materials · doi:10.1002/adom.202201714 · Cited by 525
Xu, Y., Cheng, Z., Li, Z., Liang, B., Wang, J., Wei, J., Zhang, Z., & Wang, Y. (2020) · Advanced Optical Materials · doi:10.1002/adom.201902142 · Cited by 513
The Golden Age of Thermally Activated Delayed Fluorescence Materials: Design and Exploitation
Dos Santos, J. M., Hall, D., Basumatary, B., Bryden, M., Chen, D., Choudhary, P., Comerford, T., Crovini, E., Danos, A., De, J., et al. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00755 · Cited by 457
Self-citationXu, Y., Li, C., Li, Z., Wang, Q., Cai, X., Wei, J., & Wang, Y. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.202007210 · Cited by 436
Metadata
- Authors
- Li, X., Shi, Y.-Z., Wang, K., Zhang, M., Zheng, C.-J., Sun, D.-M., Dai, G.-L., Fan, X.-C., Wang, D.-Q., Liu, W., Li, Y.-Q., Yu, J., Ou, X.-M., Adachi, C., & Zhang, X.-H.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-03-20
- Volume
- 11
- Issue
- 14
- Pages
- 13472-13480
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2923188194
- Cited by
- 226
- References
- 2
- FWCI
- 10.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.